66102A AGILENT TECHNOLOGIES, 66102A Datasheet

POWER SUPPLY, BENCH, 20V, 150W

66102A

Manufacturer Part Number
66102A
Description
POWER SUPPLY, BENCH, 20V, 150W
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of 66102A

Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
20V
Output Current
7.5A
Power Rating
150W
Weight
6lb
Approval Bodies
CSA, IEC, UL
Constant Current Setting Accuracy
0.03% + 3mA
Output Type
Variable
Rohs Compliant
NA
Calibrated
No
Lead Free Status / RoHS Status
na
66000A (mainframe)
66001A (keyboard)
Power Products Catalog 2002-2003
Agilent Performance dc Power Supplies
66000 Modular Power System
The Agilent 66000 modular power
system simplifies test-system
assembly, cabling, programming,
debugging and operation. It is
ideal for ATE and production test
environments, where it can supply
bias power and stimulus to sub-
assemblies and final products.
The modular power system
saves rack space, the 7-inch-high
(4-EIA units) mainframe can
accommodate up to eight dc
power modules.
Key Features
• GPIB-programmable voltage
• Programmable over-voltage
• Self-test initiated at power-up
• Electronic calibration over
• Over-temperature protection
• Discrete fault indicator/remote
• Five nonvolatile store-recall
• User-definable power-on state
Multiple Mainframes at
One GPIB Address
The Agilent serial link feature will
allow you to control up to 16 outputs
at one GPIB address by connecting
an auxiliary mainframe. The serial
link cable comes standard with the
and current
and over-current protection
or from GPIB command
GPIB or from keyboard
inhibit (DFI/RI)
states per output
Save rack space with 8 power supply outputs in one mainframe
Increase test throughput with advanced triggering system and
Reconfigure fast with easily swappable modules
Specifications
(at 0
otherwise specified)
For more detailed specifications see the product manual at
Modular Power System:
1200 W per mainframe GPIB
Output ratings at 40
Output voltage
Output current
Maximum power
Programming accuracy at 25
Voltage
Current
Readback accuracy
(via GPIB or keyboard
display at 25˚C ±5˚C)
Voltage
Current
Ripple and noise (20 Hz to 20 MHz)
Constant Voltage rms
peak-peak
Constant Current rms
Line regulation
Voltage
Current
Load regulation
Voltage
Current
Transient response time
Average resolution
Voltage
Current
Output voltage programming (OVP)
OVP accuracy
Supplemental Characteristics
down-loadable LIST mode
˚
to 55
speed and accuracy for test optimization
˚
C unless
˚
C
59
0.03% +
0.03% +
0.02%+
0.02%+
˚
C ±5
˚
C
66101A 66102A 66103A 66104A 66105A 66106A
0 to 8 V
0 to 16 A
128 W
3 mV
6 mA
2 mV
6 mA
2 mV
5 mV
8 mA
0.5 mV
0.75 mA
1 mV
0.5 mA
Less than 1 ms for the output voltage to recover within 100 mV of its
previous level following any step change in load current up to 10 percent
of rated current
(Non-warranted characteristics determined by design
that are useful in applying the product)
2.4 mV
4.6 mA
50 mV
250 mV
0 to 20 V
0 to 7.5 A
150 W
8 mV
3 mA
5 mV
3 mA
3 mV
7 mV
4 mA
0.5 mV
0.5 mA
1 mV
0.2 mA
5.9 mV
2.3 mA
120 mV
500 mV
0 to 35 V
0 to 4.5 A
150 W
13 mV
2 mA
8 mV
2 mA
5 mV
10 mV
2 mA
1 mV
0.3 mA
1 mV
0.2 mA
10.4 mV
1.4 mA
200 mV
800 mV
www.agilent.com/find/power
0 to 60 V
0 to 2.5 A
150 W
27 mV
1.2 mA
16 mV
1 mA
9 mV
15 mV
1 mA
2 mV
0.1 mA
2 mV
0.1 mA
18.0 mV
0.75 mA
375 mV
1 V
0 to 120 V
0 to 1.25 A 0 to 0.75 A
150 W
54 mV
0.6 mA
32 mV
0.6 mA
18 mV
25 mV
1 mA
3 mV
50 µA
4 mV
50 µA
36.0 mV
0.39 mA
750 mV
1.5 V
0 to 200 V
150 W
90 mV
0.4 mA
54 mV
0.3 mA
30 mV
50 mV
1 mA
5 mV
30 µA
7 mV
30 µA
60.0 mV
0.23 mA
1.25 mV
2.5 V

Related parts for 66102A

66102A Summary of contents

Page 1

... W per mainframe GPIB Save rack space with 8 power supply outputs in one mainframe Increase test throughput with advanced triggering system and down-loadable LIST mode Reconfigure fast with easily swappable modules Specifications 66101A 66102A 66103A 66104A 66105A 66106A ˚ ˚ ( unless otherwise specified) Output ratings at 40 ˚ ...

Page 2

... Key Literature 66000 Modular Power System Product Note p/n 5091-2497E Power Products Catalog 2002-2003 speed and accuracy for test optimization Modular Power System: 1200 W per mainframe GPIB Specifications 66101A- 66101A- 66102A- 66103A- J03 J05 (at 0 ˚ ˚ C unless Special Order Special Order ...

Page 3

Agilent Performance dc Power Supplies Down Programming: An active down- programmer sinks approximately 10% of the rated output current Calibration Interval: One year ac Input of System Mainframe Voltage 100 Vac 120 Vac 200 Vac 220 Vac 230 Vac 240 ...

Page 4

... But in each product category, we’ve also integrated the capabilities that you need for a complete power solution, including extensive measurement and analysis capabilities. Please give us a call at your local Agilent Technologies sales office, or call a regional office listed below, for assistance in choosing or using Agilent power products. ...

Related keywords