X-10GW-B Omron, X-10GW-B Datasheet - Page 6

Controllers

X-10GW-B

Manufacturer Part Number
X-10GW-B
Description
Controllers
Manufacturer
Omron
Series
Xr
Datasheets

Specifications of X-10GW-B

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
10A @ 30VDC
Actuator Type
Lever, Straight
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
110gf
Contact Form
SPDT
Contact Rating
10 Amps at 125 Volts
Actuator
Lever
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
X10GWB
Safety Precautions
Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide,
“Snap Action Switches, Technical Information” for correct use.
Precautions for Safe Use
Terminal Connection
When soldering lead wires to the Switch, make sure that the capacity
of the soldering iron is 60 W maximum. Do not take more than 5 s to
solder any part of the Switch. The characteristics of the Switch will
deteriorate if a soldering iron with a capacity of more than 60 W is
applied to any part of the Switch for 5 s or more.
Operation
• Make sure that the switching frequency or speed is within the spec-
1. If the switching speed is extremely slow, the contact may not be
2. If the switching speed is extremely fast, switching shock may
• Make sure that the actuator travel does not exceed the permissible
Precautions for Correct Use
Mounting Location
• Do not use the switch alone in atmospheres such as flammable or
• Switches are generally not constructed with resistance against
• Install the switch in a location that is not directly subject to debris
• Do not use the switch in locations subject to hot water (greater than
• Do not use the switch outside the specified temperature and atmo-
146
ified range.
OT position. The operating stroke must be set to 70% to 100% of
the rated OT.
explosive gases. Arcing and heat generation associated with
switching may cause fires or explosions.
water. Use a protective cover to prevent direct spraying if the switch
is used in locations subject to splashing or spurting oil or water,
dust adhering.
and dust from cutting. The actuator and the switch body must be
protected from accumulated cutting debris and dirt.
60°C) or in water vapor.
spheric conditions.
The permissible ambient temperature depends on the model.
(Refer to the specifications in this catalog.) Sudden thermal
changes may cause thermal shock to distort the switch and result
in faults.
switched smoothly, which may result in a contact failure or contact
welding.
damage the Switch soon. If the switching frequency is too high,
the contact may not catch up with the speed.
The rated permissible switching speed and frequency indicate the
switching reliability of the Switch.
The life of a Switch is determined at the specified switching
speed. The life varies with the switching speed and frequency
even when they are within the permissible ranges. In order to
determine the life of a Switch model to be applied to a particular
use, it is best to conduct an appropriate durability test on some
samples of the model under actual conditions.
Incorrect
General-purpose Basic Switch
Terminal box
Incorrect
Terminal box
Correct
Correct
X
• Mount a cover if the switch is to be installed in a location where
• Subjecting the switch to continuous vibration or shock may result in
• If silver contacts are used with relatively low frequency for a long
• Do not use the switch in atmospheres with high humidity or heat or in
• The switch includes contacts. If the switch is used in an atmosphere with silicon
Handling
• Set the common (COM) terminal to the positive terminal. If it is set
• When using the Switch under an inductive load, the arc suppression capa-
• Since the Switch incorporates a permanent magnet, attention must
• Since a ventilation hole is provided to avoid abnormal corrosion due
• Do not change operating positions for the actuator. Changing the
Panel-mounted Model (X-10GQ@)
• To side-mount the panel-mount Switch to the panel with screws,
• Too large a dog angle and too fast operating speed may damage
• Too fast operating speed and too long overtravel of the roller
worker inattention could result in incorrect operation or accidents.
contact failure, faulty operation or reduced service life due to
abrasion powder. Excessive vibration or shock will cause the con-
tacts to operate malfunction or become damaged. Mount the switch
in a location that is not subject to vibration or shock and in a
direction that does not subject the switch to resonance.
time or are used with microloads, the sulfide coating produced on
the contact surface will not be broken down and contact faults will
result. Use a microload switch that uses gold contacts.
harmful gases, such as sulfide gas (H
acid gas (HNO
such as with damage due to contacting faults or corrosion.
gas, arc energy may cause silicon oxide (SiO
and result in contact failure. If there is silicon oil, silicon filling, silicon wiring, or
other silicon products in the vicinity of the switch, use a contact protection cir-
cuit to limit arcing and remove the source of the silicon gas.
to the negative terminal, the Switch will not turn OFF.
bility varies depending on current. If the current becomes 0.6 to 1.2 A or of
the time constant L/R exceeds 7 ms, be sure to provide an arc suppressor.
be paid to the following points:
to operating conditions, provide a dustproofing device in locations
where the Switch is exposed to dust.
position may cause malfunction.
remove the hexagonal nut from the actuator.
the Switch when the Switch is side-mounted on the panel.
plunger Switch may result in damage to the Switch.
(a) Avoid mounting the Switch directly onto a magnetic substance.
(b) Do not subject the Switch to severe shocks.
(c) Avoid placing the Switch in a strong magnetic field.
(d) Be sure to prevent iron dust or iron chips from adhering to the
(e) Do not apply thermal shock to the Switch, or the magnetic flux
Incorrect
built-in magnet or the magnetic blowout function of the Switch
will be adversely affected.
will be diminished.
Incorrect
3
), or chlorine gas (Cl
(preventing malfunctions)
2
). Doing so may impair functionality,
2
S, SO
Correct
2
Correct
) to accumulate on the contacts
2
), ammonia gas (NH
Separate the
installation
location from
heat sources.
3
), nitric

Related parts for X-10GW-B