Specifications of UVQ-5/20-D24P-C

Dc / Dc Converter O/p Type
Single
No. Of Outputs
1
Input Voltage
18V To 36V
Power Rating
100W
Output Voltage
5V
Output Current
20A
Approval Bodies
EN / IEC / UL
Supply Voltage
24V
Rohs Compliant
Yes
Product
Isolated
Output Power
100 W
Input Voltage Range
18 V to 36 V
Number Of Outputs
1
Output Voltage (channel 1)
5 V
Output Current (channel 1)
20 A
Isolation Voltage
2 KV
Package / Case Size
Quarter Brick
Lead Free Status / Rohs Status
 Details
FEATURES
DESCRIPTION
For effi cient, fully isolated DC power in the small-
est space, DATEL’s UVQ series quarter bricks offer
output voltages from 1.2 to 48 Volts with currents
up to 40 Amps. UVQ’s operate over a wide tem-
perature range (up to +70°C at 200 lfm airfl ow) at
full-rated power. The optional mounting baseplate
extends this to all practical temperature ranges at
full power.
UVQ’s achieve these impressive specifi cations
while delivering excellent electrical performance.
Overall noise is 35mVp-p (3.3V models) with fast
step response (down to 50μsec). These convert-
www.cd4power.com
construction/attach
Standard quarter-brick package/pinout
Outputs from 1.2 to 48V up to 125W
Low profi le 0.42" height
24 and 48Vdc nominal inputs
Fully isolated, 2250Vdc (BASIC) insulation
Designed for RoHS compliance
Output overvoltage/short-circuit protected
On/Off control, trim and sense functions
Qual/HALT/EMI tested
High effi ciency to 94%
Protected against temp. and voltage limits
UL/IEC/EN60950 safety approvals
Lead-free
Pb
Typical unit
®
ers offer high stability even with no load and
tight output regulation. The unit is fully protected
against input over and undervoltage, output over-
current and short circuit. An on-board temperature
sensor shuts down the converter if thermal limits
are reached. Protection uses the “hiccup” (auto
restart) method.
A convenient remote On/Off control input operates
by external digital logic, relay or transistor input.
To compensate for longer wiring and to retain
output voltage accuracy at the load, UVQ’s include
a Sense input to dynamically correct for ohmic
ORDERING GUIDE SUMMARY
Model
All Models
With baseplate
Without baseplate
MECHANICAL CHARACTERISTICS
INPUT CHARACTERISTICS
Parameter
Voltage Range
Current, full power
Isolation
Remote On/Off Control
OUTPUT CHARACTERISTICS
Parameter
Voltage
Current
Accuracy
Ripple & Noise (to 20MHz)
Line and Load Regulation
Overcurrent Protection
Overtemperature Protection
Effi ciency (minimum)
GENERAL SPECIFICATIONS
Parameter
Dynamic Load Response
Operating Temperature Range
Safety
See Performance Specifi cations, page 2
V
1.2V to 48V
OUT
Low-Profi le, Isolated Quarter-Brick 2.5-40 Amp DC/DC Converters
Range
1.45 x 2.30 x 0.5 inches (36.83 x 58.42 x 12.7 mm)
1.45 x 2.30 x 0.42 inches (36.83 x 58.42 x 10.67 mm)
I
OUT
2.5A to 40A
Range
18-36 or 36-75 Volts
Up to 40 Amps
2kVdc to 2250V
Switch or FET control
1.2 to 48 Volts ±10%
2.5 to 40 Amps fullscale
Down to 1% of V
Down to 35mVp-p
Down to ±0.125%/±0.25%
+125 °C
See Performance Specifi cations
Down to 50μsec
–40 to +110°C
UL/IEC/EN 60950
150% of I
Typ. @ 25°C, full load
Typ. @ 25°C, full load
Typ. @ 25°C, full load
OUT
18-36V or 36-75V
max.
NOM
V
losses. A trim input may be connected to a user’s
adjustment potentiometer or trim resistors for
output voltage calibration closer than the standard
accuracy.
UVQ’s include industry-standard safety certifi ca-
tions and BASIC I/O insulation provides 2250 Volt
input/output isolation. Radiation emission testing
is performed to widely-accepted EMC standards.
Contact DATEL for details on HALT qualifi cation
testing. The UVQ’s may be considered as higher
performance replacements for some DATEL USQ
models.
IN
Range
Notes
24V or 48V nominal
Model dependent
Model dependent
Positive or negative logic
Notes
Trimmable
No minimum load
Most models
Model dependent
Model dependent
With hiccup auto-restart
Notes
Model dependent
With baseplate, see derating curve
And CSA C22.2-No.234
Up to 94%, model dependent
UVQ Series
Effi ciency
UVQ Series
Page 1 of 20

Related parts for UVQ-5/20-D24P-C

UVQ-5/20-D24P-C Summary of contents

Page 1

... For effi cient, fully isolated DC power in the small- est space, DATEL’s UVQ series quarter bricks offer output voltages from 1 Volts with currents Amps. UVQ’s operate over a wide tem- perature range (up to +70°C at 200 lfm airfl ow) at full-rated power. The optional mounting baseplate extends this to all practical temperature ranges at full power ...

Page 2

... Package (Case/ Typ. Pinout) TBD C59,P32 88% C59,P32 TBD C59,P32 TBD C59,P32 88 C59,P32 91% C59,P32 89 C59,P32 92% C59,P32 90% C59,P32 89% C59,P32 90% C59,P32 93% C59,P32 93% C59,P32 94% C59,P32 90% C59,P32 93% C59,P32 94% C59,P32 94% C59,P32 91.5% C59,P32 UVQ Series Page ...

Page 3

... L1 = 0.110 (2.79mm 0.145 (3.68mm) Blank = Standard pin length (special order) or higher models) OUT * Note: Not all model number combinations are available. Contact C&D Technologies (DATEL). REFERENCE & ERROR AMP +SENSE (7) +V OUT (8) –V OUT (4) –SENSE (5) V OUT TRIM (6) UVQ Series Page ...

Page 4

... UVQ-24/4.5-D24 UVQ-18/5.6-D24 UVQ-15/7-D24 UVQ-12/8-D24 UVQ-5/20-D24 UVQ-3.3/30-D24 UVQ-2.5/35-D24 UVQ-1.5/40-D24 ...

Page 5

... UVQ-24/4.5-D24 UVQ-18/5.6-D24 UVQ-15/7-D24 UVQ-12/8-D24 UVQ-5/20-D24 UVQ-3.3/30-D24 UVQ-2.5/35-D24 UVQ-1.5/40-D24 ...

Page 6

... UVQ-24/4.5-D24 UVQ-18/5.6-D24 UVQ-15/7-D24 UVQ-5/20-D24 UVQ-12/8-D24 UVQ-3.3/30-D24 UVQ-2.5/35-D24 UVQ-1.5/40-D24 ...

Page 7

... UVQ-48/2.5-D48 UVQ-24/4.5-D48 UVQ-18/6-D48 UVQ-15/7-D48 UVQ-12/10-D48 UVQ-5/20-D48 UVQ-3.3/35-D48 UVQ-2.5/40-D48 ...

Page 8

... UVQ-48/2.5-D48 UVQ-24/4.5-D48 UVQ-18/6-D48 UVQ-15/7-D48 UVQ-12/10-D48 UVQ-5/20-D48 UVQ-3.3/35-D48 UVQ-2.5/40-D48 ...

Page 9

... UVQ-48/2.5-D48 UVQ-24/4.5-D48 UVQ-18/6-D48 UVQ-15/7-D48 UVQ-12/10-D48 UVQ-5/20-D48 UVQ-3.3/35-D48 UVQ-2.5/40-D48 ...

Page 10

... DC/DC converter. I/O Filtering, Input Ripple Current, and Output Noise All models in the UVQ Series are tested/specifi ed for input ripple current (also called input refl ected ripple current) and output noise using the circuits and layout shown in Figures 2 and 3. ...

Page 11

... Figure 3. Measuring Output Ripple/Noise (PARD) Start-Up Threshold and Undervoltage Shutdown Under normal start-up conditions, the UVQ Series will not begin to regulate properly until the ramping input voltage exceeds the Start-Up Threshold. Once operating, devices will turn off when the applied voltage drops below the Undervoltage Shutdown point ...

Page 12

... Temperature/power derating is based on maximum output current and volt- age at the converter's output pins. Use of the trim and sense functions can cause output voltages to increase, thereby increasing output power beyond the UVQ's specifi ed rating, or cause output voltages to climb into the output overvoltage region. Therefore: ) ≤ rated output power ...

Page 13

... Note: Higher output 24V and 48V converters require larger, low-tempco, preci- sion trim resistors. An alternative is a low-TC multi-turn potentiometer (20kΩ typical) connected between +V and –V with the wiper to the Trim pin. OUT OUT www.cd4power.com Low-Profi le, Isolated Quarter-Brick 2.5-40 Amp DC/DC Converters Trim Down UVQ Series UVQ Series Page ...

Page 14

... TYPICAL PERFORMANCE CURVES www.cd4power.com Low-Profi le, Isolated Quarter-Brick 2.5-40 Amp DC/DC Converters UVQ Series UVQ Series Page ...

Page 15

... TYPICAL PERFORMANCE CURVES www.cd4power.com Low-Profi le, Isolated Quarter-Brick 2.5-40 Amp DC/DC Converters UVQ Series UVQ Series Page ...

Page 16

... TYPICAL PERFORMANCE CURVES www.cd4power.com Low-Profi le, Isolated Quarter-Brick 2.5-40 Amp DC/DC Converters UVQ Series UVQ Series Page ...

Page 17

... TYPICAL PERFORMANCE CURVES www.cd4power.com Low-Profi le, Isolated Quarter-Brick 2.5-40 Amp DC/DC Converters UVQ Series UVQ Series Page ...

Page 18

... UVQ Series Aluminum Heatsink The UVQ series converter baseplate can be attached either to an enclosure wall or a heatsink to remove heat from internal power dissipation. The discus- sion below concerns only the heatsink alternative. The UVQ’s are available with a low-profi le extruded aluminum heatsink kit, models HS-QB25-UVQ, HS-QB50-UVQ, and HS-QB100-UVQ ...

Page 19

... LFM is the minumum airfl keep the heatsink below +90°C. Increase the airfl several hundred LFM to reduce the heatsink temperature further and improve life and reliability. Heatsink height (see drawing) 0.25" (6.35mm) 0.50" (12.7mm) 1.00" (25.4mm) UVQ Series Dimensions in inches (mm) Optional Heatsink UVQ Series Page ...

Page 20

... C&D Technologies (DATEL) GmbH München, Germany Tel: 89-544334-0 Internet: www.cd4power.com E-mail: ped.gmbh@cdtechno.com C&D Technologies KK Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-6354-2025 Int.: www.cd4power.jp Email: sales_tokyo@cdtechno.com, sales_osaka@cdtechno.com China Shanghai, People's Republic of China Tel: 86-50273678 DS-0549 06/06 Internet: www.cd4power.com E-mail: shanghai@cdtechno.com UVQ Series UVQ Series Page ...