UMP-15/1.7-Q12-C Murata Power Solutions Inc, UMP-15/1.7-Q12-C Datasheet - Page 6

DC/DC TH 40W Q12-15V XMP

UMP-15/1.7-Q12-C

Manufacturer Part Number
UMP-15/1.7-Q12-C
Description
DC/DC TH 40W Q12-15V XMP
Manufacturer
Murata Power Solutions Inc
Series
UMPr
Datasheet

Specifications of UMP-15/1.7-Q12-C

Product
Isolated
Output Power
26 W
Input Voltage Range
10 V to 36 V
Number Of Outputs
1
Output Voltage (channel 1)
15 V
Output Current (channel 1)
1.7 A
Isolation Voltage
1.5 KV
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
On/Off Control (Standard)
The On/Off Control pin (pin 5) may be used for remote on/off operation. As
shown in Figure 6, the control pin has an internal 10k: pull-up resistor to
approximately 10V. The converter is designed so that it is enabled when the
control pin is left open (normal mode) and disabled when the control pin is
pulled low (to less than +0.8V relative to –Input, pin 2).
Dynamic control of the on/off function is best accomplished with a mechani-
cal relay or an open-collector/open-drain drive circuit (optically isolated if
appropriate). The drive circuit should obviously be able to sink approximately
1mA when activated and withstand more than 10 Volts when deactivated.
Applying an external voltage to pin 5 when no input power is applied to the
converter can cause permanent damage to the converter. The on/off control
function, however, is designed such that the converter can be disabled (pin
5 pulled low) while input power is ramping up and then "released" once the
input has stabilized. Under these circumstances, it takes approximately 30ms
for the output of the fully loaded DC/DC to ramp up and settle to within ±1%
of its fi nal value after the converter has been turned on.
Output Trimming
V
should be connected between +Output (pin 9) and Common (pin 8) with its
wiper connected to pin 10 (Trim). A trimpot can also be used to determine the
value of a single fi xed resistor which can be connected between pin 10 (Trim)
and pin 9 (+Output) to trim "down" the output voltages, or between pins 10
(Trim) and 6 (–Output) to trim "up" the output voltages. Fixed resistors should
be metal-fi lm types with absolute TCR's less than 100ppm/°C to ensure
stability.
Threaded Inserts and Heatsink Installation
CAUTION: Do not use the threaded inserts to bolt the converter down to a
PC board. That will place unnecessary force on the mounting pins. Instead,
the converter is held securely by only soldering the mounting pins.
When attaching the heat sink from above the converter, use a maximum
torque of 2 inch-pounds (0.23 N-m) on the 4-40 bolts to avoid damaging the
threaded inserts. Use a tiny amount of fastener adhesive or 4-40 lockwash-
ers to secure the bolts.
OUT
may be trimmed ±5% via a single trimpot or fi xed resistor. The trimpot
Figure 6. Driving the On/Off Control Pin
3
5
2
+INPUT
ON/OFF
CONTROL
–INPUT
+10V
www.murata-ps.com
10k9
6
UMP Trim Resistor Equations
The equations listed below will set the output to a desired voltage using a
single fi xed trim resistor if you do not prefer to use a potentiometer. Do not
exceed ±5% from the nominal output voltage. Trim resistors should have low
temperature coeffi cients, ±100ppm/°C or less to ensure stability. Adjustment
beyond the specifi ed adjustment range is not recommended. Attach the trim
resistors as close as practical to the converter.
To trim the voltage higher than the nominal output, install the resistor be-
tween the trim pin and –V
To trim the voltage lower than the nominal output, install the resistor between
the trim pin and +V
These equations are a starting point. The fi nal output voltage at the load will
vary slightly with load current, distance to the load (and voltage drop), input
voltage, ambient temperature, airfl ow, initial setpoint accuracy and several
other variables. For critical applications, you should measure the actual volt-
age obtained.
Case Connection
Unlike most other DC/DC converters, UMP DC/DC's do not have their metal
case connected to one of their input pins. The "uncommitted" case is con-
nected to pin 4 which, depending on your system confi guration, must be
connected to earth or chassis ground to ensure reliable operation.
Figure 8. Trim Connections Using Fixed Resistors
Figure 7. Trim Connections Using a Trimpot
OUT
Technical enquiries email: sales@murata-ps.com, tel:
terminal.
OUT
25-40W, Single Output, DC/DC Converters
terminal.
MDC_UMP25-40W_B02 Page 6 of 9
UMP Models
Note:
Install either a fi xed
trim-up resistor
or a fi xed trim-down
resistor depending upon
desired output voltage.
+1 508 339 3000

Related parts for UMP-15/1.7-Q12-C