PAXDR010 Red Lion Controls, PAXDR010 Datasheet - Page 17

no-image

PAXDR010

Manufacturer Part Number
PAXDR010
Description
DC, Dual Rate, Upgradeable Red
Manufacturer
Red Lion Controls
Type
Rate/Totalizerr
Datasheet

Specifications of PAXDR010

Accuracy
± (0.01% of Input Signal Frequency)
Cut Out, Panel
3.62W x 1.77H Inches
Digit Height
0.56
Dimensions
3.80W x 1.95H Inches
Display Digit Height
.56 Inches
Display Type
LED Adjustable
Function
Rate/Totalizer
Input Type
Switch Selectable Pulse
Keypad Type
4 Programmable Function (5 Keys Total)
Number Of Digits
6
Primary Type
Electronic
Range, Measurement
Rate = 0 to 99999, Totalizer = ±99999999
Special Features
Programmable Function Keys
Termination
Cage Clamp
Voltage, Supply
11 to 36 VDC, 24VAC
Lead Free Status / Rohs Status
RoHS Compliant part
signals. User 1 accepts Input A direction or quadrature signal.
This reset action affects all Totalizer A resets, except the Setpoint Totalizer Auto
Reset in Module 6.


SELECTION












x = Totalizer A or B
6.4 MODULE 4 - T
Select the operating mode for Totalizer A.
* Dual Count mode (
When Totalizer A is reset, it returns to zero or Totalizer A count load value.
Module 4 is the programming for Totalizer A and Totalizer B. Totalizer B parameters follow Totalizer A. For maximum input frequency, the
totalizers should be set to mode NONE when they are not in use. When set to NONE, the remaining related parameters are not accessible.
A corresponding annunciator indicates the totalizer being shown in the Display Mode. An Exchange Parameter Lists feature for scale factors
and count load values is explained in Module 2.


MODE
Count X1
Count X1
w/direction
Count X1
w/direction*
Quad X1
Quad X2
Quad X4
Quad X1*
Quad X2*
Count X2
Count X2
w/direction
Count X2
w/direction*
TOTALIZER A OPERATING MODE
TOTALIZER A RESET ACTION
     
PAR

Totalizer x
Operating
x tot
4-tot
), where Inputs A and B are both used for count
Mode
DESCRIPTION
Does not count.
Adds Input A falling edge.
Adds Input A falling edge if Input B is high.
Subtracts Input A falling edge if Input B is low.
Adds Input A falling edge if User 1 is high.
Subtracts Input A falling edge if User 1 is low.
Adds Input A rising edge when Input B is high.
Subtracts Input A falling edge when Input B is high
Adds Input A rising edge when Input B is high and
Input A falling edge when Input B is low. Subtracts
Input A falling edge when Input B is high and Input
A rising edge when Input B is low.
Adds Input A rising edge when Input B is high,
Input A falling edge when Input B is low, Input B
rising edge when Input A is low, and Input B falling
edge when Input A is high. Subtracts Input A falling
edge when Input B is high, Input A rising edge
when Input B is low, Input B rising edge when
Input A is high, and Input B falling edge when Input
A is low.
Adds Input A rising edge when User 1 is high.
Subtracts Input A falling edge when User 1 is high.
Adds Input A rising edge when User 1 is high and
Input A falling edge when User 1 is low. Subtracts
Input A falling edge when User 1 is high and Input
A rising edge when User 1 is low.
Adds Input A rising and falling edges.
Adds Input A rising and falling edges if Input B is
high. Subtracts Input A rising and falling edge if
Input B is low.
Adds Input A rising and falling edges if User 1 is
high. Subtracts Input A rising and falling edge if
User 1 is low.


   
Reset Action
xrESEt
Totalizer x

OTALIZER
xdECPt
Totalizer x
Decimal
Position
PARAMETER MENU
A & B S
Scale Factor
xSCFAC
Totalizer x
17
Load Value, and any setpoint value assigned to Totalizer A. The selection will
also affect Totalizer A scale factor calculations.
displays (same position for both). If Totalizer C is disabled, separate decimal
point positions can be selected for Totalizer A and Totalizer B.
multiplier to obtain the desired process value. A scale factor of 1.00000 will
result in the display of the actual number of input counts. (Details on scaling
calculations are explained at the end of this section.)


factor to obtain the desired process value. A scale multiplier of 1 will result in
only the scale factor affecting the display. (Details on scaling calculations are
explained at the end of this section.)
value.



This selects the decimal point position for Totalizer A, Totalizer A Count
When Totalizer C is enabled, this setting applies to both Totalizer A and B
The number of input counts is multiplied by the scale factor and the scale
The number of input counts is multiplied by the scale multiplier and the scale
When reset to count load action is selected, Totalizer A will reset to this
Totalizer A may be programmed to reset at each meter power-up.
  
xSCALr
Totalizer x
Multiplier
ETUP
Scale


TOTALIZER A RESET AT POWER-UP
TOTALIZER A COUNT LOAD VALUE
TOTALIZER A DECIMAL POSITION
TOTALIZER A SCALE MULTIPLIER
TOTALIZER A SCALE FACTOR
P
xCntLd
Count Load

Totalizer x
ARAMETERS
Value
 

  
to

  
  
to
x P-UP
Power-up
Totalizer x
Reset at
 

  
(
  
  
Pro

  
)