PAXCDC1C Red Lion Controls, PAXCDC1C Datasheet - Page 19

no-image

PAXCDC1C

Manufacturer Part Number
PAXCDC1C
Description
Extnd. RS485 Card W/Dual RJ11 Connector
Manufacturer
Red Lion Controls
Datasheet

Specifications of PAXCDC1C

Brand/series
PAXDR
Card Type
Option Communications
Communication
Serial RS485
Data Protocols
7/8 bits, 300 to 19,200 baud, no, even or odd parity
Pax Label Kit
189 Different Engineering Units, Labels Inserted Inside the Unit
Lead Free Status / Rohs Status
RoHS Compliant part
the Totalizer C Calculation should be set to
,
annunciator indicates that Totalizer C is being shown in the Display Mode. An
Exchange Parameter List feature for the Scale Factor is explained in Module 2.
assigned to Totalizer C. The selection will also affect Totalizer C scale factor
calculations.
Scale Multiplier to obtain the Totalizer C display value. Normally, a scale factor
of 1.00000 is used to show the calculated result without any further scaling
applied. If however, additional scaling is needed, the scale factor can be set to
provide the desired reading.



SELECTION
6.5 MODULE 5 - T
Module 5 is the programming for Totalizer C. For maximum input frequency,
Select the calculation for Totalizer C display.
This selects the decimal point position for Totalizer C and any setpoint value
The result of the Totalizer C calculation is multiplied by the Scale Factor and






  
the remaining Totalizer C parameters are not accessible. The C

ACTION
No Calculation. Totalizer C disabled.
TOTALIZER A - Totalizer C shows Totalizer A with additional
scaling applied per the Totalizer C scaling parameters.
SUM (A+B). Totalizer C shows the sum of Totalizer A and
Totalizer B.
DIFFERENCE (A-B). Totalizer C shows the difference of Totalizer
A and Totalizer B.
RATIO (A/B). Totalizer C shows the percentage of Totalizer A to
Totalizer B.
PERCENT OF TOTAL (A/A+B). Totalizer C shows the percentage
of Totalizer A to the sum of Totalizer A and Totalizer B.
TOTALIZER C DECIMAL POSITION
TOTALIZER C SCALE FACTOR
TOTALIZER C CALCULATION
PAR
Calculation
5-totC
Totalizer C
C tot


 
  


  
to
  

CdECPt
Totalizer C
  
Decimal
Position
when not in use. When set to
OTALIZER


  
  
PARAMETER MENU
Scale Factor
CSCFAC
Totalizer C
C S
19
ETUP
For Totalizer C percentage calculations, the result is internally multiplied by
10,000 to show percentage in hundredths with a scale multiplier of 1 (select 2
decimal places). By using a scale multiplier of 0.1 or 0.01, along with the proper
decimal point position, the display can be divided down to show percentage in
tenths or in whole numbers respectively.


Set the Scale Multiplier to provide the desired Totalizer C display resolution.
Totalizer C may be programmed to reset at each meter power-up.
CSCALr
Totalizer C
Multiplier
Scale
P

TOTALIZER C RESET AT POWER-UP
ARAMETERS
TOTALIZER C SCALE MULTIPLIER
C P-UP
Totalizer C
Power-up
Reset at

(
Pro

 

  
)