HWK60000 Red Lion Controls, HWK60000 Datasheet - Page 4

Bezel Kit, SCUBD

HWK60000

Manufacturer Part Number
HWK60000
Description
Bezel Kit, SCUBD
Manufacturer
Red Lion Controls
Datasheet

Specifications of HWK60000

Accessory Type
Bezel Kit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
SubCub 2-8A, D, T
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
HWK-60-000/A
HWK-60000
HWK6
RLC10
TYPICAL APPLICATIONS
DISPLAY FOR SPEED OF SMALL PRINTING PRESS
printing press in both tenths of feet per minute and in tenths of meters per
minute. When the press is running at its maximum rate, the web is turning at
a rate of 1800 RPM, and the press is running at 250 feet per minute (76.2
meters per minute). The drive control produces a signal of 60 pulses per
revolution of web. To align the registration marks in the set-up mode, the
press speed is only 25 feet per minute.
speed. This logic pulse is fed through a buffer to the Signal input of the SUB-
CUB-R. The time base is determined by the position of the Selector switch.
In the first position, the SUB-CUB-R display will read out in tenths of feet per
minute. In the second position, the display will be in tenths of meters. Note
that Frequency Doubling is used to reduce the update time of the SUB-CUB-
R. The first decimal point is turned on by the logic levels of DPA and DPB.
FLOW RATE
be used as a flow indicator to measure the flow of liquid. A flow gage
with a magnetic type output is used to sense the rotation of the impellor,
and its output is fed through an amplifier circuit to the SIG input. Since
the output of the flow gage is an A.C. voltage, diodes D1 and D2 are
used to clamp the output signal swing to within ±0.7 volts of the supply
voltage. Diode D3 is used to prevent the voltage from rising above 6.0
VDC to prevent damaging the SUB-CUB-R. The time base of the SUB-
CUB-R is set to 0.5 sec (TB8 is connected to V
is enabled (FD is connected to V
produce the appearance of a 1 second time base which updates twice a
second. The time base of the SUB-CUB-R can be varied to produce
different time bases required for different fluids. A second position
decimal point is selected (DPA and DPB are connected to V
The SUB-CUB-R can be used to indicate the speed of the web of a small
The controller for the press provides a logic pulse which corresponds to its
The SUB-CUB-R, along with some signal conditioning circuitry, can
easily plugs onto standard 0.1” spacing bread boards. This in turn, greatly simplifies bread board work.
This board is a handy way of doing experimental and prototyping work with the SUB-CUB-R. It
DD
SUB-CUB-R PROTOTYPING BOARD (P/N DMOSCB04)
). This will allow the meter to
SUB-CUB-R
PROTOTYPING
BOARD
P/N DMOSCB04
SS
). Frequency doubling
DD
).
4
meters per minute, use the following formula.
To determine the proper TB input settings for both feet per minute and for
TB8
TB6
TB5
TB2
TB6
TB5
TB3
TB2
= 178 (rounded off to the nearest whole number)
TIME BASE INCREMENT
= 54 (rounded off to the nearest whole number)
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
TOTAL (TBIT)
= 177.8 ( ÷2 when using F.D.)
TBIT =
= 54.2 ( ÷2 when using F.D.)
TBIT =
For Meters Per Minute:
For Feet Per Minute:
-
-
-
-
-
-
-
-
TBIT = 178
TBIT = 178
76.20 x 10 x 15,360
250.0 x 10 x 15,360
= 355.6
= 108.4
128
32
16
32
16
1800 x 60
2
4
2
1800 x 60
=
DR x DDP x 15,360
Needed = 50
Needed = 18
Needed = 2
Needed = 0
Needed = 22
Needed = 6
Needed = 2
Needed = 0
RPM x PPR