215570-6 Tyco Electronics, 215570-6 Datasheet - Page 7
215570-6
Manufacturer Part Number
215570-6
Description
CONN PADDLEBRD 6POS VERT 28AWG
Manufacturer
Tyco Electronics
Series
Micro-MaTchr
Specifications of 215570-6
Connector Type
Ribbon Cable
Number Of Positions
6
Pitch
0.100" (2.54mm)
Number Of Rows
2
Row Spacing
0.100" (2.54mm)
Mounting Type
Through Hole
Cable Termination
Solder
Wire Gauge
28 AWG, Stranded or Solid
Features
Feed Through
Contact Finish
Tin
Color
Red
Number Of Positions Loaded
All
Contact Material
Phosphor Bronze
Contact Plating
Tin
Lead Spacing
1.27mm
No. Of Rows
2
No. Of Ways
6
Termination
RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Contact Finish Thickness
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
215570-6
Manufacturer:
TE
Quantity:
20 000
Company:
Part Number:
215570-6
Manufacturer:
AMP
Quantity:
35 000
.
Rev. F
R6-77 (Rev. 07-01)
3.6.10.
3.6.11.
3.6.12
3.6.13
3.6.9.
Termination resistance
SMC types
Termination resistance
SMD types
Termination resistance paddle
board.
Contact retention in housing.
Mechanical operation
Test description
E L E C T R I C A L (continued)
Max. open voltage 20 mV
Max. current 100 mA
Termination resistance consists of
IDC slot resistance + contact
resistance +bulk connectors +
resistance contact member
Pcboard + PCB path.
Requirement: 10 mΩ max.
(exclude bulk resistance)
Max. open voltage 20 mV
Max. current 100 mA
Termination resistance consists of
bulk resistance of contact + solder
connection.
Requirement: 10 mΩ max.
Max. open voltage 20 mV
Max. current 100 mA
Termination resistance consists of
IDC slot resistance + contact bulk
resistance
Requirement: 10 mΩ max.
Requirements:
contact.No dislodge from housing.
Contact retention in housing
male on wire conector
Number of operations: 20
Frequency: 10 times/min.
Minimum time between 2
operations: 1 sec.
Performance Requirements
MECHANICAL
or Severity
10 N min. per
In acc. With IEC 512-2 test 2a
Under dry circuit conditions
All contacts measured.
In acc. With IEC 912 test 2a
Under dry circuit conditions
All contacts measured.
In acc. With IEC 512-2 test 2a
Under dry circuit conditions
All contacts measured.
In acc. with IEC 512-8 test 5b.
(COSI: 512-8 test15a)
Contact retention in housing
female connector
In acc. with IEC 512-5
test 9a.
Procedures
108-19052