FX-301P PANASONIC EW, FX-301P Datasheet - Page 119

no-image

FX-301P

Manufacturer Part Number
FX-301P
Description
AMPLIFIER,[NAVI] DIGITAL, RED, PNP, 12-24VDC, QD
Manufacturer
PANASONIC EW
Datasheet
With the CC-Link SC-GU2-C communication unit, you can to
connect to a CC-Link open network, allowing you to monitor or
change settings via a PLC, PC, etc. Batch communication can
even be executed when connected to FX-301/305 series digital
fiber sensors or DPS-401/402 series digital pressure sensors.
This function tracks changes in the light emitting amount over
long periods, such as those caused by dust levels, and thresh-
old values can be reset automatically, helping reduce mainte-
nance costs.
Features
The DPS-400 series has answered industry’s call to downsize
pressure sensors at production sites and conveniently fit into
most machines and reduction of man-hours when it comes to
replacement.
Quick-connection cables not only reduce wiring, they reduce
the time necessary for setting up relay terminals, and they save
space. DPS-400 series controllers can be connected side-
by-side with FX-300 series fiber sensors or LS series laser
sensors.
* Check the instruction manual of each model for the arrangement order such when
supply cable
Only output lines are used, so that wiring can be greatly reduced and space saving can be obtained.
Main cable CN-74-C
connecting as communication varies depending on the model.
Network communication
Threshold tracking function
Thin controller lineup
Saves wire and space
FX-300 series
Fiber sensor
Output line 1 Output line 2
Wire-saving in power supply*
DPS-400, FX-300, LS-400, etc.
Up to 16 sensors can be connected togetther
DPS-400 series
Output line 2’
Output line 3
Sub cable CN-72-C
Output line 3’
Output line 16
DPS-400 series
Output line 16’
04/2011
The controller is equipped with a 4-digit dual digital display,
which allows you to adjust the threshold value while checking
the current value (current pressure value), i.e. it is no longer
necessary to switch screen modes.
Current value and threshold value can
be checked simultaneously on the dual
display
Up to 16 sensors allowed in optical communication / setting copying
LS 400