CUB4L820 Red Lion Controls, CUB4L820 Datasheet - Page 4

no-image

CUB4L820

Manufacturer Part Number
CUB4L820
Description
Multifunction Counter
Manufacturer
Red Lion Controls
Datasheet

Specifications of CUB4L820

No. Of Digits / Alpha
8
Backlighting Color
Red
Panel Cutout Height
1.3"
Display Mode
LCD Negative Image Transmissive
Meter Signal Input
Pulse
Character Size
0.46"
Panel Cutout Width
2.68"
Ip/nema Rating
IP65 / NEMA 4X
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Red Lion Controls
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
5 KHz when driven by bi-polar outputs or external circuits having an output
impedance of 3.3 KΩ or less. Input drive voltage must be limited to 3 V
maximum to avoid damage to the counter. CMOS and TTL logic outputs can
be loaded with a resistor (Rl) to limit drive voltage, or a voltage divider can
be used as shown for the PNP O.C. transistor output.
RESET OPTIONS
Common will enable the front panel Reset button. When Remote Reset is
required, a wire is connected from the “REM. RST.” input terminal to
Common. Pulling this input low causes the counter to reset. The “REM. RST.”
can be pulled low by either a mechanical switch or solid-state transistor
switch. Switch load and leakage are the same as for “L.S. CNT.” Input above.
Note: The RC protection circuit on the “REM. RST.” Input causes a delay of
CUB4L8 HIGH SPEED COUNT INPUT, 5 Hz MAX.
The “H.S. CNT.” Input allows the CUB Counter to operate at speeds up to
Connecting a wire from the “RST. EN.” (Reset Enable) Input terminal to
approximately 15 msec in Reset response.
TROUBLESHOOTING
For further technical assistance, contact technical support at the appropriate company numbers listed.
NL - 3821 AD Amersfoort
Fax +31 (0) 334 893 793
Tel +31 (0) 334 723 225
Red Lion Controls BV
Printerweg 10
BACKLIGHT OPTION
power supply. The external supply is connected between the V+ and Common
terminals as shown in the drawing.
attached directly to the rear of a CUB4 and is powered from a 85 to 250 VAC
source. The MLPS provides power for unit backlighting and a sensor.
TTL OR CMOS
Optional backlight versions of the CUB4 require an external 9-28 VDC
Red Lion Controls optional power supply (MLPS1000) is designed to be
OUTPUT
FIG 1
WARNING: When connecting the wiring for a backlit CUB4L8W
INPUT PULSE EXCURSION LIMITS
measuring an AC input voltage, the neutral of the single phase AC
signal is connected to Terminal 1 (COM), and line (hot) is
connected to Terminal 5 (LS). The DC supply for the backlighting
is connected as shown in the drawing. Three phase AC applications
require an isolation transformer.
V
IN
(High) = 2.0 V min., 3.0 V max.
V
IL
(Low) = ±0.5 V max.
PNP O.C. TRANSISTOR
OR BI-POLAR OUTPUT
FIG 2
Building 13, No.99 Tianzhou Road
ShangHai, P.R. China 200223
Fax +86 21 6113-3683
Tel +86 21 6113-3688
+12 V
+18 V
+24 V
Unit 101, XinAn Plaza
+5 V
Red Lion Controls AP
R values for
+V
TRANSISTOR
Fig 2 & 3
NPN O.C.
FIG 3
2.2 K
10 K
16 K
24 K
R

Related parts for CUB4L820