T3-1-8200/EA/SVB MOELLER, T3-1-8200/EA/SVB Datasheet

ISOLATOR, FLUSH, 32A, 1POLE

T3-1-8200/EA/SVB

Manufacturer Part Number
T3-1-8200/EA/SVB
Description
ISOLATOR, FLUSH, 32A, 1POLE
Manufacturer
MOELLER
Datasheet

Specifications of T3-1-8200/EA/SVB

No. Of Poles
1
Contact Voltage Ac Max
440V
Contact Current Ac Max
32A
Svhc
No SVHC (18-Jun-2010)
Approval Bodies
UL, CSA
Current Rating
32A
Ip/nema Rating
IP55
Operating Voltage
690VAC
Power
RoHS Compliant
Type: T3−1−8200/EA/SVB
Article No.: 066576
Sales text ON−OFF SWITCH
1
Ordering information
Produktgruppen−Bezeichnung
Design
Basic type for ... insert mounting form
Mounting form
No. of poles
Description
General
Standards
Lifespan, mechanical
Maximum operating frequency
Climatic proofing
Operations/h
Operations
M
× 10
BME−CAT Fotos
T3−...
Load current switches
Main switches, maintenance
switches
Flush mounting
T3−1−8200/...
EA/SVB
1
As Emergency−Stop device
6
IEC/EN 60947, VDE 0660,
IEC/EN 60204, CSA, UL
Switch−disconnectors to
IEC/EN 60947−3
Load−break switches to
IEC/EN 60947−3
0,5
3000
Damp heat, constant, to IEC
60068−2−78; Damp heat,
cyclical, to IEC 60068−2−30

Related parts for T3-1-8200/EA/SVB

T3-1-8200/EA/SVB Summary of contents

Page 1

... Type: T3−1−8200/EA/SVB Article No.: 066576 Sales text ON−OFF SWITCH Ordering information Produktgruppen−Bezeichnung Design Basic type for ... insert mounting form Mounting form No. of poles Description General Standards Lifespan, mechanical Maximum operating frequency Climatic proofing 1 BME−CAT Fotos T3−... Load current switches ...

Page 2

Ambient temperature Open Enclosed Mounting position Mechanical shock resistance to IEC 60068−2−27 Contacts Rated operational voltage Rated impulse withstand voltage Overvoltage category/pollution degree Rated uninterrupted current open Enclosed Load rating with intermittent operation, class ...

Page 3

Switching capacity AC Rated making capacity cos = 0.35 Rated breaking capacity, motor load switch cos = 0.35 230 V 400 V 500 V 690 V Rated operational current 440 V load−break switch AC−21A AC−3 motor load switch motor rating ...

Page 4

... < 10 Fault probability H F operations For mechanical shock resistance: T3.../I... >12g Applies to T0(3).../SVB: isolating characteristics to IEC/EN 60947 Ufor rated operational voltage up to 500 V AC Applies to rated uninterrupted current I the contact: with T5−4−8344/I5 max For terminal capacity solid, stranded and flexible: T0(3), (6), (8)...: Maximum of 2 cross− ...

Page 5

Dimensions not included Depth of a contact unit: 11.5 mm Dimensions 3 padlocks Characteristic curve 5 difference admissible between 2 conductors For type T8−3−8342/... the following applies: switching angle = 90° and flat connection = 1 busbar 25 × 5 ...

Page 6

... The blocked rotor current of the motor should not exceed the rated current of the switch for AC−21A to ensure a reasonable device lifespan. Moeller GmbH, Hein−Moeller−Str. 7−11, D−53115 Bonn E−Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net HPL−C2007G V2.1 © 2007 by Moeller GmbH 6 ...

Related keywords