K3HB-SSD 100/240VAC Omron, K3HB-SSD 100/240VAC Datasheet - Page 26

METER, SENSOR, LINEAR, 100/240AC

K3HB-SSD 100/240VAC

Manufacturer Part Number
K3HB-SSD 100/240VAC
Description
METER, SENSOR, LINEAR, 100/240AC
Manufacturer
Omron
Datasheet

Specifications of K3HB-SSD 100/240VAC

Power Consumption
18VA
Svhc
No SVHC (15-Dec-2010)
External Depth
95mm
External Length / Height
48mm
Ip/nema Rating
IP20
Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Supply
RoHS Compliant
Approval Bodies
CE, CRUus, UL
Current Consumption
50mA
Rohs Compliant
Yes
For Use With
High-speed,
■ Main Functions
Measurement
• Two input circuits are provided. The input ranges for these circuits
• In addition to calculations such as K (constant)–A (input for one cir-
Normal
• Continuously performs measurement and always outputs based on
Peak Hold/Bottom Hold
• Measures the maximum (or minimum) value in a specified period.
Scaling converts input signals in any way required before displaying
them. The values can be manipulated by shifting, inverting, or +/–
reversing.
Settings for scaling can be made using the present measurement
values instead of inputting values with the SHIFT and UP Keys. This
is a convenient function for making the settings while monitoring the
operating status.
26
Display value 2
Display value 1
Input Calculation
Timing Hold
H comparative set value
Measurement value
Scaling
Teaching
Standby Sequence
Display value
can be set independently. For example, one can be set to 4 to 20
mA and the other can be set to 1 to 5 V.
cuit), it is possible to perform calculations based on the inputs for
both circuits, such as A+B and A–B, making it possible to perform
thickness measurement and level-difference measurement using
displacement and length-measuring sensors.
comparative results.
Measurement value
(dsp.a2)
(dsp.a1)
TIMING
input
OFF
Input
H output
ON
Input value 1
(inp.a1)
Digital Indicators
Input
(Scaling)
Input value 2
(inp.a2)
Input value
Display value 2
Display value 1
Display value
K3HB-X/-V/-H/-S
(dsp.a2)
(dsp.a1)
S
X V H S
X V S
X V S
X V H S
Input value 2
(inp.a2)
(Reverse scaling)
Peak hold value
Input value 1
Bottom hold value
(inp.a1)
Time
Time
Input value
Sampling Hold
• Holds the measurement at the rising edge of the TIMING signal.
Peak-to-peak Hold
• Measures the difference between the maximum and minimum val-
Turns the comparative output OFF until the measurement value
enters the PASS range.
Average processing of input signals with extreme changes or noise
smooths out the display and makes control stable.
Slight changes can be removed from input signals to detect only
extreme changes.
Shifts the temperature input value.
Average Processing
Previous Average Value Comparison
Temperature Input Shift
Measurement value
K
ues in a specified period.
Measurement value
Supported Models
The models that support the functions shown here are indi-
cated by symbols as follows:
X
V
H
S
TIMING
TIMING
K3HB-X
K3HB-V
K3HB-H
K3HB-S
input
A
input
OFF
Input
Input
OFF
ON
ON
a1
K−A
b1
(b1−a1)
'a2
X V H S
X V H S
H
'b2
Sampling hold value
Peak-to-peak value
(b2−a2)
Time
Time

Related parts for K3HB-SSD 100/240VAC