ETM1411-2307 CAL CONTROLS, ETM1411-2307 Datasheet

DIGITAL TIMER, 1 X RELAY, 230VAC

ETM1411-2307

Manufacturer Part Number
ETM1411-2307
Description
DIGITAL TIMER, 1 X RELAY, 230VAC
Manufacturer
CAL CONTROLS
Datasheet

Specifications of ETM1411-2307

Supply Voltage Range
184VAC To 253VAC
Operating Time Range
Selectable 0.01 To 99.59 Min Or Hour
Power Consumption
3VA
External Depth
70mm
External Length / Height
34mm
External Width
77mm
Ip/nema Rating
IP60 Front Panel / IP20 Rear Panel
Rohs Compliant
Yes
Digit Height
12mm
Input Voltage Max
230VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SUPPLY:
184-253V AC
50/60Hz 3VA
NOTE :
Connection Diagram
SN: XXXXXXXXX
1
Thank you for choosing the CAL ETM1411 digital timer.
* 34 x 77mm sized.
*
*
*
*
*
*
*
*
*
0:01 .... 99:59 min.
0:01 .... 99:59 hour
ETM1411-230VAC
DIGITAL TIMER
Single contact output for timing control.
External start input.
Display can be adjusted to show min. or sec.
Scale ;
Decrease and increace step of time can be adjusted.
Start and stop possibility by front panel.
16 different warning tones.
Upper and lower limits of the setpoint can be adjusted.
CE marked according to European Norms.
Output
Relay
2
CAL ETM1411 DIGITAL TIMER
3
4
www.cal-controls.com
7
8
5
12V AC/DC %10
24V AC/DC %10
Supply Voltage
230V AC +%10 -%20
CAL ETM 411 is intended for installation in control panels. Make sure that the device is
used only for intended purpose. The shielding must be grounded on the instrument side.
During an installation, all of the cables that are connected to the device must be free of
electrical power. The device must be protected against inadmissible humidity, vibrations,
severe soiling and make sure that the operation temperature is not exceeded. All input and
output lines that are not connected to the supply network must be laid out as shielded and
twisted cables. These cables should not be close to the power cables or components. The
installation and electrical connections must be carried out by qualified staff and must be
according to the relevant locally applicable regulations.
6
Neutral
7
Line
8
9
Fuse should
be connected.
1
10
±
±
F 100 mA
250V AC
Fuse
11
START
12
Switch
Cable size: 1,5mm²
SN: XXXXXXXXX
1
ETM1411-230VAC
ETM1411-12
ETM1411-24
Order Code
ETM1411-12
DIGITAL TIMER
2
3
4
www.cal-controls.com
230V AC
Supply
5
6
7
1)
2)
8
IEC 60227 or IEC 60245.
supply switch shall bring the identification of
the relevant instrument and it should be easily accessible
by the operator.
Note:
Mains supply cords shall meet the requirements of
In accordance with the safety regulations, the power
9 10 11 12
START
ETM1411
CAL
OUT
DIGITAL TIMER
Holding screw
0.4-0.5Nm
HOUR
Equipment is protected throughout
by DOUBLE INSULATION.
MIN
SET
START
STOP
1/2
Dimensions
CAL CONTROLS LTD
Bury Mead Road, Hitchin, Herts, SG5 1RT, UK.
Tel : +44 (0) 1462 436161
e-mail: sales@cal-controls.co.uk
TECHNICAL SPECIFICATIONS
On and Off times for input pulses
ENVIRONMENTAL CONDITIONS
Ambient/storage temperature
Supply
Power consumption
Wiring
Scale
Sensitivity
Time Accuracy
Indicator
EMC
Safety requirements
OUTPUT
OUT
Life expectancy for relay
START INPUT
Input type
HOUSING
Housing type
Dimensions
Weight
Enclosure material
Max. Relative humidity
Rated pollution degree
Height
ELECTRICAL CHARACTERISTICS
ETM1411
CAL
OUT
Do not use the device in locations subject to corrosive and flammable gases.
While cleaning the device, solvents (thinner, benzine, acid etc.) or
START
12
11
10
DIGITAL TIMER
HOUR
9
8
85mm
MIN
7
ETM1411-230VAC
6
TIMER
Fax : +44 (0) 1462 451801
5
XXXXXXXXX
2.5mm² screw-terminal connections
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.
The device is designed to operate in controlled electromagnetic environment)
EN 61010-1: 2001 (
Relay: 250V AC, 8A (
Suitable for panel mounting
W77xH34xD70mm
Approx. 240g (after packing)
Self extinguishing plastics
4
230V AC +%10 -%20, 50/60Hz or 24V AC/DC %10, 50/60Hz or 12V AC/DC %10, 50/60Hz.
Max 3VA
Selectable 99:59 min. or hour.
1 sec.
±%1
4 digits, 12mm, 7 parts yellow LED
Mechanical 30.000.000 operation; Electrical 100.000 operation
SET
DIGITAL
3
0 ... +50°C/-25 ... +70°C (with no icing)
80% up to 31°C decreasing linearly 50% at 40°C.
According to EN 60529
Max.
2
Web : www.cal-controls.com
START
SN:
STOP
1
Control with mechanical contact.
Min. = 100ms, Max. =
2000m
1
pollution degree 2, overvoltage category II
mounting
For removing mounting clamps:
for resistive load
clamp
Push out the mounting clamp
in direction
in the figure below. Then, pull
out the clamp in direction
4
Panel cut-out
1
as shown
Front panel :
Rear panel :
), NO+NC
71mm
±
2.
corrosive materials
mounting
Ip20
clamp
IP60
Note: 1) Panel thickness
)
2) If there is no 60mm
Depth
should be maximum
7 mm.
free space at the back
side of the device, it
would be difficult to
remove it from the panel.
70mm
must not be used.
2
±
Panel
ETM1411-E-03
Rubber
gasket
8mm

Related parts for ETM1411-2307

ETM1411-2307 Summary of contents

Page 1

... CAL ETM1411 DIGITAL TIMER Thank you for choosing the CAL ETM1411 digital timer 77mm sized. * Single contact output for timing control. * External start input. * Display can be adjusted to show min. or sec. * Scale ; 0:01 .... 99:59 min. 0:01 .... 99:59 hour * Decrease and increace step of time can be adjusted. ...

Page 2

... Stop key Indicator Power Out TYP.1 Start input Indicator CONTROL DIAGRAM BY START & STOP KEYS Out.t. TYP.0 Str.t. Power Out Start TYP.2 key Stop key Indicator Power Out Start TYP.3 key Stop key Indicator key, the value can be TYP.1 TYP.1 ETM1411-E-03 ...

Related keywords