61FGPN8H240AC Omron, 61FGPN8H240AC Datasheet - Page 9

LEVEL CONTROLLER

61FGPN8H240AC

Manufacturer Part Number
61FGPN8H240AC
Description
LEVEL CONTROLLER
Manufacturer
Omron
Datasheet

Specifications of 61FGPN8H240AC

Supply Voltage
240VAC
Response Time
80ms
Power Consumption
3.5VA
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
CE, CSA, UL Recognised
Dielectric Strength Vac
2000VAC
External Depth
70mm
External Length /
RoHS Compliant
■ Compact Plug-in Models (8-pin Type)
Specifications
Note: 1. The relay in the 61F-GP-N8H/-N8Y de-energizes when there is water present across the Electrodes, whereas the relay in the 61F-GP-
Controlling mate-
rials and operat-
ing conditions
Supply voltage
Operating voltage
range
Interelectrode
voltage
Interelectrode
current
Power consump-
tion
Interelectrode op-
erate resistance
Interelectrode re-
lease resistance
Response time
Cable length
(see note 2)
Control output
Ambient tempera-
ture
Ambient humidity Operating: 45% to 85% RH
Insulation resis-
tance
(see note 3)
Dielectric
strength
(see note 3)
Life expectancy
Weight
2. The length when using completely-insulated, 600-V, 3-conductor (0.75 mm
3. The insulation resistance and dielectric strength indicate values between power terminals and Electrode terminals, between power ter-
4. Possible to use with 10 k or less, however, this may cause reset failure.
Item
N8HY energizes when there is water present across the Electrodes.
the cable diameter or number of conductors becomes larger.
minals and contact terminals, and between Electrode terminals and contact terminals.
http://www.ia.omron.com/
For control of ordi-
nary purified water
or sewage water
24, 100, 110, 120, 200, 220, 230 or 240 VAC; 50/60 Hz
85% to 110% of rated voltage
8 VAC
Approx. 1 mA AC max.
Approx. 3.5 VA max.
0 to approx. 4 k
Approx. 15 k to
Operate: 80 ms max.
Release: 160 ms max.
1 km max.
1 A, 250 VAC (Inductive load: cos = 0.4)
3 A, 250 VAC (Resistive load)
Operating: –10 C to 55 C
100 M
2000 VAC, 50/60 Hz for 1 min.
Electrical:
Mechanical: 5,000,000 operations min.
Approx. 155 g
General-purpose
61F-GP-N8Y
(see note 1)
61F-GP-N8
Controller
min. (at 500 VDC)
100,000 operations min.
For control of ordi-
nary purified water
in cases where the
distance between
sewage pumps and
water tanks or be-
tween receiver
tanks and supply
tanks is long or
where remote con-
trol is required.
0 to 1.3 k (for
2 km)
0 to 0.5 k (for
4 km)
4 k to
(for 2 km)
2.5 k to
(for 4 km)
2 km max.
4 km max.
61F-GP-N8L 2KM
61F-GP-N8L 4KM
Long-distance
Controllers
(for 2 km)
(for 4 km)
For control of liq-
uids with high spe-
cific resistance
such as distilled
water
24 VAC
Approx.
0.4 mA AC max.
Approx. 15 k to
approx. 70 k
(see note 4)
Approx. 300 k to
50 m max.
High-sensitivity
61F-GP-N8HY
61F-GP-N8H
(see note 1)
Controllers
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
For control of liq-
uids with low spe-
cific resistance
such as salt water,
sewage water, acid
chemicals, alkali
chemicals
8 VAC
Approx. 1 mA AC max.
0 to approx. 1.3 k
Approx. 4 k to
1 km max.
2
) cabtire cables. Usable cable lengths will become shorter as
Low-sensitivity
61F-GP-N8D
Controller
For control of ordi-
nary purified water
or sewage water
used in combina-
tion with Two-wire
Electrode Holder
(incorporating a re-
sistor of 6.8 k )
0 to approx. 2 k
Approx. 15 k to
800 m max.
61F-GP-N8R
Controller
Two-wire
61F-GP-N@
Approx. 3 mA AC
For control of cases
where variable sen-
sitivity control is re-
quired such as
detection of froth on
the surface of a liq-
uid, control of soil
moisture content,
or detection of de-
gree of water pollu-
tion
24, 110, 220 or
240 VAC; 50/60 Hz
24 VAC
max.
0 to 50 k (Vari-
able)
Operating resis-
tance +50 k max.
50 m max.
61F-GP-N8-V50
Sensitivity
Controller
Variable
9