2132VH EUROTHERM CONTROLS, 2132VH Datasheet - Page 2

PID TEMPERATURE CONTROLLER

2132VH

Manufacturer Part Number
2132VH
Description
PID TEMPERATURE CONTROLLER
Manufacturer
EUROTHERM CONTROLS
Datasheet

Specifications of 2132VH

Thermocouple Type
J, K, T, L, N, R, S, B
Operating Temperature Max
55°C
Operating Temperature Min
0°C
Output Voltage Max
264VAC
Output Voltage Min
12V
Accuracy
± 0.25%
Ambient Conditions
0-55C
Lead Free Status / RoHS Status
na
Dimensions
Electrical connections
Part No. HA026158 Issue 2
Ordering Code
EUROTHERM CONTROLS LIMITED
http://www.eurotherm.co.uk
UK SALES OFFICE
Eurotherm Controls Limited. Faraday Close, Durrington, Worthing, West Sussex BN13 3PL
Telephone Sales: (01903) 695888; Technical: (01903) 695777; Service: (01903) 695444
Fax (01903) 695666
Sales and support in over 30 countries worldwide
Enquiries/orders to: Eurotherm Controls Limited Export Dept., Faraday Close, Durrington, Worthing. West Sussex BN13 3PL.
Telephone (01903) 268500, Fax (01903) 265982
© Copyright Eurotherm Controls Limited 1997
All rights strictly reserved. No part of this document may be stored in a retrieval system, or any form or by any means without prior written permission from Eurotherm Controls Limited. Every effort has been
taken to ensure the accuracy of this specification. However in order to maintain our technological lead we are continuously improving our products which could, without notice, result in amendments or
omissions to this specification. We cannot accept responsibility for damage, injury, loss or expenses resulting therefrom.
2132 48 x 24mm unit
2116 48 x 48mm unit
CC PID Controller
NF ON/Off Controller
TC PID Controller + Timer
TN ON/Off Contr’ + Timer
XXX No manual
ENG English
FRA French
GER German
NED Dutch
SPA Spanish
SWE Swedish
ITA
VH 85-264Vac
VL 20-29V dc or ac
2132
24 mm
(0.95in)
2132
mA Input
PT100
Model Number
Supply Voltage
T/C
Italian
Function
Manual
Sensor inputs
1B
V-
1B
-
Output 1
(Logic)
2.49
Solid
State
Relay
OP1
OP2
OR
48 mm (1.89in)
1A
1A
V+
+
AB
2132
Outpt 2
(Relay)
Note 1. PDS heater
break detect will transmit
the power demand to a
TE10S Solid State Relay
and read beck a heater
break alarm.
Number
Model
XX No function
Logic output
LH Heating
LC Cooling
M1 PDS heater break
FH High alarm 1
FL Low alarm 1
DB Dev. band alarm 1
DL Dev. low larm 1
DH Dev. high alarm 1
NW New alarm
Logic input
AC Alarm ack/reset
KL Keylock
TM Timer Off/On
AA
Low voltage supply
Output 1 (Logic)
External
Module
Relay
detect (note 1)
Neutral
20-29Vac/dc
85-264Vac
24
N
Function
Line
24
L
103 mm (4.01in)
Voltage
Supply
XX No function
RH Heating
RC Cooling
FH High alarm 2
FL Low alarm 2
AL High alarm 2 & low
DB Dev. band alarm 2
DL Dev. low larm 2
DH Dev. high alarm 2
NW New alarm
Specifications
Supply voltage:
85-264Vac, 48-62Hz, or 20-29Vac/dc, 5watts max
Operating ambients:
0-55°C, 5-95%RH non-condensing
Output ratings:
Logic: 9Vdc, 12mA (non-isolated)
(Can also be used as alarm acknowledge, keylock
and timer start/stop input)
Relay: 2A, 264V ac resistive
Calibration accuracy:
± 1°C or ± 0.25% of reading whichever is greater
Cold junction compensation:
>15 to 1 rejection of ambient temperature change
Input filtering:
Off to 999.9 seconds
Output 2 (Relay)
alarm 3
2116
Manual
External
Module
Relay
Output 1
(Logic)
0.88
22.2
Panel cut-out
1A
1B
Thermocouples
J
K
T
L
N
R
S
B
P
Resistance thermometer
Z
Custom downloaded inputs
C
D
E
1
2
3
4
5
6
7
8
Process inputs (linear)
M
Y
A
V
- 0.0
+ 0.01
- 0.0
+ 0.3
Sensor Input
x 1.77in
x 45 mm
OR
Type J
Type K
Type T
Type L
Type N
Type R
Type S
Type B
Platinell II
Pt100
Type C - W5%Re/W26%Re
Type D - W3%Re/W25%Re
E Thermocouple
Ni/Ni18%Mo
Pt20%Rh/Pt40%Rh
W/W26%Re (Englehard)
W/W26%Re (Hoskins)
W5%Re/W26%Re (Englehard)
W5%Re/W26%Re (Bucose)
Pt10%Rh/Pt40%Rh
Exegen K80 I.R. pyrometer
-9.99 to +80mV
0 to 20mA (note 3)
4 to 20mA (note 3)
0 to 10Vdc (input adapter required)
(default custom sensor)
Output 2
(Relay)
- 0.0
+ 0.02
- 0.0
+ 0.6
Solid
State
Relay
2116
48 mm
(1.89in)
Sensor
Input
48 mm (1.89in)
OP1
OP2
Setpoint
note 2
Min.
Output 1
Setpoint Min/Max
(Logic)
Timer range:
0-9999 minutes
Setpoint rate limit adjustment:
0-999.9 least significant display unit per minute.
Adjustable hysteresis
Alarm configuration:
High, low, deviation band, deviation high and low
EMC standards:
Meets generic emissions standard EN50081-2 and
immunity standard EN50082-2 for industrial
environments
Safety standard:
Meets EN61010, installation category II. Pollution
degree 2
Atmospheres:
Not suitable for use above 2000m or in explosive or
corrosive atmospheres
2116
1A
1B
note 2
Setpoint
Max.
-1999
-1999
-1999
-1999 to 9999
+
-210
-200
-200
-200
-200
-200 to
-200
-
Min °C Max
200
-50
-50
-45
10
0
0
0
0
0
0
0
0
0
to 1200
to 1372
to
to 1300
to 1768
to 1768
to 1820
to 1369
to 2319
to 2399
to
to 1399
to 1870
to 2000
to 2010
to 2300
to 2000
to 1800
to
to 9999
to 9999
to 9999
to
AA
AB
V+
V-
N
L
103 mm (4.01in)
400
900
850
999
650
Units
T/C
Output 2
Line
85-264Vac
Neutral
(Relay)
PT100
Ext. Relay
Note 2. Setpoint min and
max: include the decimal
position required in the
display value; up to one for
temperature input, up to two
for process inputs.
Note 3. An external 1%
current sense resistor is
supplied as standard. If
greater accuracy is required
specify ‘A1’ in the Input
Adaptor field.
Module
C
F
K
X
XX Not fitted
R7 Fitted (Operated by the
XX Not fitted
V1 0-10Vdc
A1 0-20mA or 4-20mA
External Relay Module
Low voltage supply
°C
°F
Kelvin
Linear input
logic output)
0.1% current sense
resistor (2.49Ω)
Input Adaptor
mA Input
24
24
2.49
Units
20-29Vac/dc
Adaptor
1.77 x 1.77in
45 x 45 mm
Input
Panel cut-out
Sensor
inputs
- 0.00
+ 0.02
- 0.0
+ 0.6

Related parts for 2132VH