KFD2-SR2-EX-1.W PEPPERL & FUCHS, KFD2-SR2-EX-1.W Datasheet

ISOLATION AMPLIFIER

KFD2-SR2-EX-1.W

Manufacturer Part Number
KFD2-SR2-EX-1.W
Description
ISOLATION AMPLIFIER
Manufacturer
PEPPERL & FUCHS
Datasheet

Specifications of KFD2-SR2-EX-1.W

Input Type
Intrinsically Safe
Output Type
Relay
No. Of Output Channels
1
No. Of Input Channels
1
Supply Voltage Range
20VDC To 30VDC
Isolation Input
Isolated
Operating Temperature Max
60°C
No. Of Channels
1
No. Of Outputs
1
Operating Temperature Range
-20°C To +60°C
Signal Conditioner Input
Digital
Signal Conditioner Output
Relay
Transformer Isolated Barriers
24 V DC:
• 1-channel
• Control circuit EEx ia IIC
• Reversible mode of operation
• 1 relay output with 1 changeover
• EMC acc. to NAMUR NE 21
• LB/SC monitoring
• LB/SC combined error signal via Po-
Function
The transformer isolated barrier transfers
digital signals from the hazardous area. Sen-
sors per DIN EN 60947-5-6 (NAMUR) and
mechanical contacts may be used as
alarms. Control circuits are monitored for
lead breakage (LB) and short circuit (SC).
The external faults are indicated according
to NAMUR NE44 by a red flashing LED. For
type KFD2-SR2-Ex1.W, an LB/SC combined
error signal is in addition transferred through
the Power Rail to the power feed module.
The
DIN EN 50020 safely isolated from the out-
put and the power supply. The relay output is
in
section 101 safely isolated from the power
supply.
1
contact
wer Rail
accordance
intrinsically
Subject to reasonable modifications due to technical advances.
Pepperl+Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore (6) 7 79 90 91 • Internet http://www.pepperl-fuchs.com
with
safe
DIN
input
EN 0106
is
per
without SC
without LB, SC
Construction
1+
1+
1+
1+
Input I EEx ia IIC
yellow
S1
10 k
2+
2+
I
400
10 k
&
II
SC
LB
3-
3-
3-
3-
3-
R 2 k
7
Output
red
8
S3
9
green
Power
supply
14 15
+
Switch S3 in position I
Switch S3 in position I
Switch S3 in position I
Switch S3 in position II
-
Copyright Pepperl+Fuchs, Printed in Germany
+
Power
only
KFD2-SR2-Ex1.W
KFD2-SR2-Ex1.W
rail
-
LB/SC -
collective
error message
Output: Relay

Related parts for KFD2-SR2-EX-1.W

KFD2-SR2-EX-1.W Summary of contents

Page 1

... Control circuits are monitored for lead breakage (LB) and short circuit (SC). The external faults are indicated according to NAMUR NE44 by a red flashing LED. For type KFD2-SR2-Ex1.W, an LB/SC combined error signal is in addition transferred through the Power Rail to the power feed module. The ...

Page 2

... A for 115 V AC switching voltage. The respective connection data are shown on the type plate switchings approx approx < safe galvanic isolation acc 50020, voltage peak value 375 V safe galvanic isolation acc 50020, voltage peak value 375 V KFD2-SR2-Ex1.W Copyright Pepperl+Fuchs, Printed in Germany 2 ...

Page 3

... Power Rail UPR 05 Power feed module KFD2-EB2 The devices are supplied with due to the power feed module KFD2-EB2 and via the Power Rail UPR 05, simultaneously the combined fault indication will be evaluated. Each power feed module serves the fusing and monitoring of groups with up to 100 single devices. The PR 05 Power Rail is an inset component for the DIN rail ...

Page 4

... Subject to reasonable modifications due to technical advances. Pepperl+Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330 • Singapore ( • Internet http://www.pepperl-fuchs.com KFD2-SR2-Ex1.W Copyright Pepperl+Fuchs, Printed in Germany 4 ...

Related keywords