H7AN-4D-AC100-240 Omron, H7AN-4D-AC100-240 Datasheet - Page 4

COUNTER DIGITAL LED

H7AN-4D-AC100-240

Manufacturer Part Number
H7AN-4D-AC100-240
Description
COUNTER DIGITAL LED
Manufacturer
Omron
Datasheet

Specifications of H7AN-4D-AC100-240

Rohs Compliant
YES
Digit Height
72mm
Supply Voltage Range
100VAC To 240VAC
Counting Speed
30Hz
Operating Temperature Range
-10°C To +55°C
No. Of Digits / Alpha
4
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Totalizing Counters
Incrementing/Decrementing Counters
Reversible Counters
Incrementing, Decrementing, and Reversible Counters
■ Ratings
*The ripple is 20% max.
**There is an inrush current of 14 A at 240 VAC for approximately 0.6 ms, 15 A at 12 to 24 VDC for 2 ms, 5 A at 48 VDC for 3 ms, or 8 A at 100 VDC
for 2 ms immediately after power-ON.
***Only preset counters can be automatically reset.
Operating method
Mounting method
Input signal method (Count, reset input) Contact and solid-state input voltage (H and L)
Memory backup
Display
Models
Rated supply voltage
Operating voltage range
Power consumption
Max. counting speed of
CP1 and CP2
Reset
Control output
Min. applicable load
External power supply
Ambient temperature
Ambient humidity
Case
Operating method
Mounting method
Input signal method (Count, reset input) Contact and solid-state input voltage (H and L)
Memory backup
Display
Models
Operating method
Mounting method
Input signal method (Count, reset input) Contact and solid-state input voltage (H and L)
Memory backup
Display
Models
4 digits
4 digits
6 digits
8 digits
100 to 240 VAC, 50/60 Hz (common use); 12 to 24, 48, 100 VDC*
85% to 110% of rated voltage
Approx. 10 VA (240 VAC at 50 Hz); Approx. 5 W (at 24 VDC)**
2-digit counters: 30 Hz
4-digit counters: 30 Hz or 5 kHz
6- or 8-digit counters: 30 Hz or 5 kHz
Minimum signal width (with ON/OFF ratio of 1:1): 30 Hz: 16.7 ms, 5 kHz: 0.1 ms
H: 4.5 to 30 VDC, L: 0 to 2 VDC
Power supply reset (except for H7AN Counter with suffix “-M”):
Minimum power-OFF time: 0.5 s with a reset time of 0.05 s after power-ON.
External, manual, reset signal time: 0.02 s
Reset time after completion of reset signal: 0.05 s
Automatic reset***
Contacts: 3 A at 250 VAC, resistive load (cosφ = 1)
No-contacts: 100 mA max. at 30 VDC max., open collector
10 mA at 5 VDC (p level reference value)
80 mA, 12 VDC ±10% (contains 5% ripple max.)
Operating: –10°C to 55°C (with no icing)
Storage: –25°C to 65°C (with no icing)
35% to 85%
Light gray (Munsell 5Y7/1)
Reversible (selectable with rotary DIP switch) between 0 and the full scale
Incrementing/decrementing A/D (command inputs)
Incrementing/decrementing B/E (individual inputs)
Incrementing/decrementing C/F (phase difference inputs)
Flush mounting
No
Yes (10-mm high 7-segment LED)
H7AN-ET4
Incrementing and decrementing (selectable with DIP switch)
Flush mounting
No
Yes (10-mm high 7-segment LED)
H7AN-T4
Incrementing, decrementing, and reversible (UP/DOWN A to F)
Flush mounting
No
Yes (8-mm high 7-segment LED)
H7AN-RT6
H7AN-RT8
Yes/No (Selectable using DIP switch)
H7AN-T4M
Yes/No (Selectable using DIP switch)
H7AN-ET4M
Yes/No (Selectable using DIP switch)
H7AN-RT6M
H7AN-RT8M
H7AN
4

Related parts for H7AN-4D-AC100-240