E5CK-TAA1-500 AC100-240 Omron, E5CK-TAA1-500 AC100-240 Datasheet - Page 2

PROCESS CONTROLLER

E5CK-TAA1-500 AC100-240

Manufacturer Part Number
E5CK-TAA1-500 AC100-240
Description
PROCESS CONTROLLER
Manufacturer
Omron
Series
E5CKr
Type
Digital Controller, Programmabler
Datasheet

Specifications of E5CK-TAA1-500 AC100-240

Rohs Compliant
YES
Input Type
Current, Voltage, RTD, Thermocouple (Multiple)
Controller Type
On/Off
Temperature Range
Selectable, Varies By Input Type
Output Type
Output Units Available
Supply Voltage
100 ~ 240VAC
Size
53mm W x 53mm H
Features
Terminal Cover
Display Type
4 Digit (2), LEDs
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Communications
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E5CK-TAA1-500AC100-240
E5CKTAA1500AC100240
Note: A single Output Unit and Option Unit can be mounted to each Base Unit.
Inspection Report
The Digital Controller can be provided together with an inspection report.
Refer to the following legend with the suffix “K” when ordering a model provided together with an inspection report.
■ Accessories (Order Separately)
Specifications
■ Ratings
■ Input Ranges
Platinum Resistance Thermometer
Output Unit
Option Unit
Terminal Cover
Supply voltage
Power consumption
Operating voltage range
Input
Input impedance
Control output
Auxiliary output
Control method
Setting method
Indication method
Other functions
Range
Resolution ( C/ F)
(main setting and alarm)
Input (switch selectable)
E5CK-AA1-K, E53-CKF-K
Name
Description
Description
Item
C
F
http://www.ia.omron.com/
0
199.9 to 650.0
199.9 to 999.9
E53-COV07
JPt100
AC100 to 240V, 50/60 Hz
15 VA
85% to 110% of rated supply voltage
Thermocouple:
Platinum resistance thermometer: JPt100, Pt100
Current input:
Voltage input:
Current input: 150
Voltage input: 1 M
According to Output Unit (see Output Unit Ratings and Characteristics)
SPST-NO, 1 A at 250 VAC (resistive load)
ON/OFF or 2-PID control (with auto-tuning)
Digital setting using front panel keys
7-segment digital display and LEDs
According to Option Unit (see Output Unit Ratings and Characteristics)
Model
E53-R4R4
E53-Q4R4
E53-Q4HR4
E53-C4R4
E53-C4DR4
E53-V44R4
E53-Q4Q4
E53-Q4HQ4H
E53-CK01
E53-CK03
E53-CKB
E53-CKF
1
199.9 to 650.0
199.9 to 999.9
Pt100
AC100-240V type
min.
Model
Model
K, J, T, E, L, U, N, R, S, B, W, PLII
4 to 20 mA, 0 to 20 mA
1 to 5 V, 0 to 5 V, 1 to 10 V
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
AC/DC24V, 50/60 Hz
6 VA, 3.5 W
Relay/Relay
Pulse (NPN)/Relay
Pulse (PNP)/Relay
Linear (4 to 20 mA)/Relay
Linear (0 to 20 mA)/Relay
Linear (0 to 10 V)/Relay
Pulse (NPN)/Pulse (NPN)
Pulse (PNP)/Pulse (PNP)
RS-232C
RS-485
Event input: 1 point
Transfer output (4 to 20 mA)
AC/DC24V type
Specification
Specification
E5CK
2