F0301 Omron, F0301 Datasheet - Page 5

STAINLESS STEEL ELECTRODE, 1M

F0301

Manufacturer Part Number
F0301
Description
STAINLESS STEEL ELECTRODE, 1M
Manufacturer
Omron
Datasheet

Specifications of F0301

Accessory Type
Electrode
Length
1m
Svhc
No SVHC (15-Dec-2010)
External Length / Height
1m
Standard
Stainless Steel
For Use With
Purified Water Applications
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
■ Electrode Holder Precautions
Precautions for Correct Use
• Never mount the Electrode Holder horizontally. Mounting the
• The resin may become discolored after long-term use or storage.
• When wiring the BF, use M6 crimp terminals.
• Do not pull on the cable.
• Disconnect the wiring with the Level Controller before inspecting
• Use OMRON 61F Floatless Switches for control devices.
• Consult with your OMRON representative before using the BF in
Precautions for Tightening Torque and Work
Note: 1. A gasket is supplied with the BS-1. A gasket is not required
• Always use an F03-11 Protective Cover if the BF-3 (-5) is used
BS-1
(See
note 1.)
BS-1T
(See
note 1.)
Electrode Holder horizontally may cause liquid to leak from the
Electrode Holder and result in 61F reset failure.
This is normal and does not present any problems in using the
product.
Electrode Holders.
any liquid other than water.
outdoors or in locations subject to water, dust, dirt, or other foreign
matter. Foreign matter adhering to the electrode insulators may
cause incorrect operation due to leaking.
2. Wind commercially available sealing tape two or three times
3. When installing the wiring, secure nut 2 with a wrench so
to mount the BS-1T. (One is not supplied.)
around the M18 screw section before tightening the screws.
that no force is applied to the terminal bolt, and complete the
tightening with nut 1 (as in the following figure). If nut 2 is not
secured, the load on the terminal bolt may cause leakage of
steam and pressure.
Wire installation section (M4) (See note 3.)
Electrode Holder installation section (M18)
(See note 2.)
Wire installation section (M4) (See note 3.)
Electrode Holder installation section (M18)
(See note 2.)
Terminal bolt
Wire
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
http://www.ia.omron.com/
In the interest of product improvement, specifications are subject to change without notice.
Crimp terminal
1
2
6500.0 N·cm
137.2 N·cm
137.2 N·cm
196.1 N·cm
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
5