E53-C3N Omron, E53-C3N Datasheet
E53-C3N
Specifications of E53-C3N
Related parts for E53-C3N
E53-C3N Summary of contents
Page 1
Advanced Digital Temperature Controller E5AN-H/E5EN-H A New High-performance Controller: High Resolution, High Speed, and High Input Accuracy. With Logic Operations and preventive maintenance functions. Plus Infrared Port on Front Panel. • High-resolution display with 5 digits/0.01°C display. • High-speed sampling ...
Page 2
... Universal input Option Units E53 Function EN01: RS-232C communications EN02: RS-422 communications EN03: RS-485 communications AKB: Event input Output Units E53 Function RN: relay QN: pulse (PNP) 12 VDC Q3: pulse (NPN) 12 VDC Q4: pulse (PNP) 24 VDC C3N: linear C3DN: linear V34N: linear V35N: linear E5AN-H/E5EN-H ...
Page 3
... Valve 2 Note: Add power supply voltage to model to complete ordering code (ie. E5AN-HAA2HBM-500 AC100-240 or E5AN-HAA2HBMD-500 AC/DC24) Note: Heater alarm = heater burnout + SSR short detection + SSR overcurrent Note: For output option modules (AA), see “output modules E53-_ N“ on page 2 Heater Control output 1/2 Event burnout ...
Page 4
... Note: Add power supply voltage to model to complete ordering code (ie. E5EN-HAA2HBM-500 AC100-240 or E5EN-HAA2HBMD-500 AC/DC24 Note: Heater alarm = heater burnout + SSR short detection + SSR overcurrent Note: For output option modules (AA), see "output modules E53-_ N" on page 2 Accessories (Order Separately) USB-infrared Conversion Cable Model ...
Page 5
... Relay output: SPST-NO, 250 VAC (resistive load), electrical life: 100,000 operations, minimum applicable load: output Output specifications Number of outputs 2 (standard (with an E53-AKB) Contact input: ON: 1 kΩ max., OFF: 100 kΩ min. Event External contact input input Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max. ...
Page 6
Input Ranges Thermocouple/Platinum Resistance Thermometer (Fully Universal Inputs) Input Platinum resistance type thermometer Name Pt100 JPt100 2300 1800 1700 1600 1500 1400 1300.0 1300 1200 1100 1000 850.0 900 800 700 600 500.0 500.0 500.0 500 400 300 200.00 200 ...
Page 7
Alarm Outputs Each alarm can be independently set to one of the following 15 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be ...
Page 8
Characteristics Thermocouple: (±0.1% of indicated value or ±1°C, whichever is greater) ±1 digit max. ✽1 Platinum resistance thermometer: (±0.1% of indicated value or ±0.5°C, whichever is greater) ±1 digit max. Analog input: ±0.1% FS ±1 digit max. Indication accuracy CT ...
Page 9
USB-Serial Conversion Cable Applicable OS Windows 2000, XP, or Vista Thermo Mini, CX-Thermo version Applicable software 4.0 or higher E5AN/E5EN/E5CN/E5CN-U/ Applicable models E5AN-H/E5EN-H/E5CN-H USB interface standard Conforms to USB Specification 1.1. DTE speed 38400 bps Computer: USB (type A plug) ...
Page 10
Electrical Life Expectancy Curve for Relays (Reference Values) 500 300 E5AN-H/E5EN-H 100 250 VAC, 30 VDC (resistive load) cosφ Switching current (A) 10 Advanced Digital Temperature ...
Page 11
... USE USE DON’ USE EV4 (Load: 600 Ω max Advanced Digital Temperature Controller Communications E53-EN02 E53-EN03 E53-AKB RS-422 RS-485 11 RDB 11 B (+) 11 12 RDA (− NOT USE B (+) 21 SDB SDA 22 A (− Auxiliary output 3 15 Auxiliary output 3 Relay output SPDT, 250 VAC ...
Page 12
... Mode Key 120 min ✽ Group mounting is not possible if an SSR output is used for control output and the E53-C3N or E53-C3DN Output Unit is used. For these combinations, maintain the following mounting space between Controllers. Terminal Cover Mounting Bracket (E53-COV16) (Accessory) (Accessory) Crimp terminal size: M3 ...
Page 13
... Mounted Separately +0 120 min. ✽ Group mounting is not possible if an SSR output is used for control output and the E53-C3N or E53-C3DN Output Unit is used. For these combinations, maintain the following mounting space between Controllers. 91 Terminal Cover (E53-COV16) (Accessory) Crimp terminal size: M3.5 120 min ...
Page 14
... Accessories (Order Separately) USB-Infrared Conversion Cable E58-CIFIR USB-Infrared Conversion Cable USB connector (type A plug) Mounting Adapter USB-Serial Conversion Cable E58-CIFQ1 Terminal Covers E53-COV16 (Six Covers provided.) 14 Advanced Digital Temperature Controller (2,000) With Mounting Adapter Connected 16 18.5 Mounting Adapter (Accessory) 99.2 23.1 21 ...
Page 15
... IP66. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required ...
Page 16
Advanced Digital Temperature Controller E5AN-H/E5EN-H ...
Page 17
Operation E5EN-H / E5AN-H Start in manual mode. Start in automatic mode. Press the O Key or the PF Key for at least 1 s. ✽4 a-m Press the O Key for at least 3 s while a-m is displayed. ...
Page 18
E5EN-H / E5AN-H Some parameters are not displayed depending on the model of the Controller and parameter settings. For details, refer to the E5CN-H/E5AN-H/ E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157). Protect Level PID Setting Level Display ...
Page 19
Press the PF Key for at least 1 s. ✽1 Press the O Key less than 1 s. Adjustment Level Adjustment Level Display Displayed only l.adj p c once when Proportional Band entering 8.0 adjustment level ...
Page 20
Press the O Key for at least 1 s. Press the O Key for at least 3 s. Other than the Auto/Manual Switch display Protect Level The time taken to move to the protect level can be adjusted by changing ...
Page 21
Power ON Manual Control Level Operation Adjustment Protect Level Level Level Communica- Initial Setting tions Setting Level Level Advanced Function Setting Level Press the O Key for at least 1 s. Advanced Function Setting Level o-dp MV Display init Parameter ...
Page 22
Safety Precautions !CAUTION Do not touch the terminals while power is being supplied. Doing so may occasionally result in minor injury due to electric shock. Do not allow pieces of metal, wire clippings, or fine metallic shavings or filings from ...
Page 23
ON power to the load (e.g., heater) at the same time as or before supplying power to the product. If power is turned ON to the product before turning ON power to the load, self-tuning will ...
Page 24
... Mounting Brackets little by little to maintain balance, until the ratchet turns freely. Mounting the Terminal Cover E5AN/E5EN Slightly bend the E53-COV16 Terminal Cover to attach it to the terminal block as shown in the following diagram. The Terminal Cover cannot be attached in the opposite direction. Slightly bend the ...
Page 25
Advanced Digital Temperature Controller E5@N/E5@N-H 25 ...
Page 26
... OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE ...