G4OAC24 OPTO 22, G4OAC24 Datasheet - Page 3

I/O Module

G4OAC24

Manufacturer Part Number
G4OAC24
Description
I/O Module
Manufacturer
OPTO 22
Type
Outputr
Datasheets

Specifications of G4OAC24

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
No. Of Analog Outputs
1
Supply Voltage Min
19.5VDC
Signal Input Type
19.5 To 32VDC
Output Current
3A
Supply Voltage Max
32VDC
Brand/series
G4 Series
Connection To Host
Backplane
Current, Input
18 mA
Dimensions
48.8mmL×12.2mmW×41.1mmH
Module Type
Digital
Number Of Channels
1
Output
12 to 140 VAC
Output Type
Digital
Output, Range
12 to 140 VAC
Primary Type
Data Acquisition
Resistance, Insulation
100 Megohms (Min.) @ 500 VDC
Special Features
Optical Isolation
Standards
UL Listed
Voltage, Isolation
4000 VAC
Voltage, Operating
12 to 140 VAC
Voltage, Supply
24 VDC
Contact Configuration
SPST-NC
Count Input Frequency
65Hz
No. Of Outputs
1
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
G4 Digital AC Output Modules
Specifications (cont.)
Nominal line voltage
Output voltage range
Key feature
Current rating:
At 45 °C ambient
At 70 °C ambient
UL Motor Load Rating
Isolation input-to-output
Off-state leakage at
nominal voltage (60 Hz)
Logic voltage range
Logic pickup voltage
Logic dropout voltage
Logic input current at
nominal logic voltage
Control resistance
(Rc in schematic)
One-cycle surge
Turn-on time @ 60 Hz
Turn-off time @ 60 Hz
Peak repetitive voltage
Minimum load current
Output voltage drop
maximum peak
Operating frequency
dV/dT-off-state
dV/dT-commutating
Temperature
Operating:
Storage:
* One-half cycle maximum. Module turns on at the zero volt crossing of the AC sine wave.
** One-half cycle maximum. Module turns off at the zero current crossing of the AC sine wave.
© 2006 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations.
SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com
mA
A peak
Units
V
VDC
VDC
VDC
VAC
VAC
VAC
V/µs
mA
mA
ms
ms
Hz
RMS
°C
°C
A
A
A
V
--
RMS
power factor load
snubbed for 0.5
G4OAC15
-30 to +70
-30 to +85
10.5–16
12–140
25–65
4,000
≤8.3
≤8.3
10.5
120
500
200
1.5
1.6
1K
15
80
20
3
2
5
1
**
*
Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com
power factor load
snubbed for 0.5
G4OAC15A
-30 to +70
-30 to +85
120/240
1.25/2.5
10.5–16
24–280
25–65
4,000
≤8.3
≤8.3
10.5
500
200
1.5
1.6
1K
15
80
20
3
2
1
**
*
power factor load
snubbed for 0.5
G4OAC24
-30 to +70
-30 to +85
19.5–32
12–140
25–65
≤8.3
4,000
≤8.3
2.2K
19.5
500
120
200
1.5
1.6
18
80
20
3
2
5
1
**
*
power factor load
snubbed for 0.5
G4OAC24A
-30 to +70
-30 to +85
120/240
1.25/2.5
19.5–32
24–280
25–65
4,000
≤8.3
≤8.3
2.2K
19.5
500
200
1.5
1.6
18
80
20
3
2
1
**
*