INFS-0200-DC1 NEWPORT ELECTRONICS, INFS-0200-DC1 Datasheet - Page 56
INFS-0200-DC1
Manufacturer Part Number
INFS-0200-DC1
Description
Strain Gauge Meter
Manufacturer
NEWPORT ELECTRONICS
Datasheet
1.INFS-0000-DC1.pdf
(149 pages)
Specifications of INFS-0200-DC1
No. Of Digits / Alpha
6
Meter Range
0mV To 100mV
Digit Height
13.7mm
Power Consumption
6W
Operating Temperature Range
0°C To +50°C
Signal Input Type
0 To 100mV Voltage
Lead Free Status / RoHS Status
na
- Current page: 56 of 149
- Download datasheet (2Mb)
Engineering
Scaling to
8
Display
Units
8.4 SCALING YOUR METER WITHOUT CONNECTING A
SENSOR USING CALCULATED VALUES
NOTE: If after zeroing the display with RDF OF, the reading again
drifts from zero, the required offset value is the sum of the current
RDG OF value and the current converted offset value. The ex-
amples below illustrate the calculation of required offset values
when using an independent decimal. If you are using an active
decimal point, the current converted offset value is simply the
negative value of the display reading.
Example 1: You use a RDG OF value of –1.0000 to zero the meter.
The next morning, the meter displays 00.0008 at zero input; you
need to rezero. The current count value is 000008; shifting this
value to the left of the decimal makes it 08.0000, and making the
value negative makes it –8.0000. The required RDG OF value is
the sum of the current RDG OF value (–1.0000) and the current
converted offset value (–8.0000):
Example: You use a RDG OF value of –1.0000 to zero the meter.
The next morning, the meter displays –0.0008 at zero input; you
need to rezero. The current count value is –00008; shifting this
value to the left of the decimal makes it –8.0000, and making the
value positive makes it 08.0000. The required RDG OF value is
sum of the current RDG OF value (–1.0000) and the current
converted offset value (08.0000):
If you require further configuration(s) for your specific application,
refer to Sections 9 through 21.
NOTE: Should you receive an error code of any kind while
configuring your meter, refer to Section 17 - Troubleshooting -
Display Messages and Troubleshooting Guide.
Your meter can be scaled without connecting a sensor and taking
measured values using Input Scale and Offset (“IN.SC.OF”).
The typical configuration and scaling of your meter is a
0-100 mVdc input with a display equal to 0 to 100000. If your
–1.0000 + –8.0000 = –9.0000
–1.0000 + 08.0000 = 07.0000
8-12
Related parts for INFS-0200-DC1
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
Strain Gauge Meter
Manufacturer:
NEWPORT ELECTRONICS
Datasheet:
Part Number:
Description:
Strain Gauge Meter
Manufacturer:
NEWPORT ELECTRONICS
Datasheet:
Part Number:
Description:
Strain Gauge Meter
Manufacturer:
NEWPORT ELECTRONICS
Datasheet:
Part Number:
Description:
DISPLAYS / ELECTRONIC,INFB ULTRA HIGH PERFORMANCE METER,DISPLAYS / ELECTRONIC,PHOTOMOS RELAY,METERS,INF-B ULTRA HIGH PERFORMANCE METER ,NEWPORT ELECTRONICS
Manufacturer:
NEWPORT ELECTRONICS
Part Number:
Description:
DISPLAYS / ELECTRONIC,INFB ULTRA HIGH PERFORMANCE METER,DISPLAYS / ELECTRONIC,PHOTOMOS RELAY,METERS,INF-B ULTRA HIGH PERFORMANCE METER ,NEWPORT ELECTRONICS
Manufacturer:
NEWPORT ELECTRONICS
Part Number:
Description:
DISPLAYS / ELECTRONIC,INFB ULTRA HIGH PERFORMANCE METER,DISPLAYS / ELECTRONIC,PHOTOMOS RELAY,METERS,INF-B ULTRA HIGH PERFORMANCE METER ,NEWPORT ELECTRONICS
Manufacturer:
NEWPORT ELECTRONICS
Part Number:
Description:
DISPLAYS / ELECTRONIC,INFB ULTRA HIGH PERFORMANCE METER,DISPLAYS / ELECTRONIC,PHOTOMOS RELAY,METERS,INF-B ULTRA HIGH PERFORMANCE METER ,NEWPORT ELECTRONICS
Manufacturer:
NEWPORT ELECTRONICS
Part Number:
Description:
NEWPORT ULTRA-MINIATURE TEMPERATURE TRANSMITTERS
Manufacturer:
NEWPORT ELECTRONICS
Part Number:
Description:
Isolation Amplifier
Manufacturer:
NEWPORT ELECTRONICS
Datasheet:
Part Number:
Description:
Signal Conditioning, Output Isolator
Manufacturer:
NEWPORT ELECTRONICS
Datasheet:
Part Number:
Description:
Signal Conditioning, Output Isolator
Manufacturer:
NEWPORT ELECTRONICS
Part Number:
Description:
Signal Conditioning, Output Isolator
Manufacturer:
NEWPORT ELECTRONICS
Datasheet: