CUB5IB00 Red Lion Controls, CUB5IB00 Datasheet - Page 3

Current Meter

CUB5IB00

Manufacturer Part Number
CUB5IB00
Description
Current Meter
Manufacturer
Red Lion Controls
Type
Currentr
Datasheets

Specifications of CUB5IB00

No. Of Digits / Alpha
5
Meter Function
DC Ammeter
Meter Range
200uA To 200mA
Digit Height
12.2mm
Operating Temperature Range
-35°C To +75°C
Display Mode
LCD Selectable Transmissive
Supply Voltage Max
28VDC
Accuracy
±0.01% %
Connection Type
Screw
Cut Out, Panel
2.68×1.3 "
Dimensions
2.95"L×1.86"W×1.54"H
Display Digit Height
0.48 "
Display Type
LCD
Function
Current
Material, Casing
Plastic
Number Of Digits
5
Primary Type
Electronic
Range, Measurement
200 μA to 200 mA
Special Features
Communication and Control
Voltage, Supply
9 to 28 VDC
Power Supply
9 to 28 VDC
Dc Current
200 μA to 200 mA
Dc Voltage
200 mV to 200 V
Process Signals
0(4) to 20 mA or 0 - 10 VDC
Backlighting Color
Red Or Green
Character Size
0.48"
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
ADDING OPTION CARDS
communications cards. The details for the plug-in cards can be reviewed in the
specification section below. The plug-in cards, that are sold separately, can be
installed initially or at a later date.
Note: Measurement errors may occur if signal input common is shared with
SINGLE RELAY CARD
DUAL SINKING OUTPUT CARD
INSTALLATION
unit is intended to be mounted into an enclosed panel. Prepare the panel cutout
to the dimensions shown. Remove the panel latch from the
unit. Slide the panel gasket over the rear of the unit to
the back of the bezel. The unit should be installed
fully assembled. Insert the unit into the panel
cutout.
latch over the rear of the unit so that the tabs of
the panel latch engage in the slots on the case.
INPUT RANGE JUMPER
in programming must match the jumper setting. Select a range that is high
enough to accommodate the maximum signal input to avoid overloads. To
access the jumper, remove the rear cover of the meter.
REMOVING THE REAR COVER
input terminals. To release the tab, insert a small, flat blade screwdriver between
the tab and the plastic wall below the terminals. Inserting the screwdriver will
provide enough pressure to release the tab locks. To replace the cover, align the
cover with the input terminals and press down until the cover snaps into place.
O
1.0 I
2.0 S
The CUB5 meters can be fitted with optional output cards and/or serial
another circuit common (ie, serial common, Dual Sinking Output option card,
or Power Supply common) on multiple units.
Type: Single FORM-C relay
Isolation To Sensor & User Input Commons: 1400 Vrms for 1 min.
Contact Rating: 1 amp @ 30 VDC resistive; 0.3 amp @ 125 VAC resistive
Life Expectancy: 100,000 minimum operations
Type: Non-isolated switched DC, N Channel open drain MOSFET
Current Rating: 100 mA max.
V
The meter meets NEMA 4X/IP65 requirements when properly installed. The
While holding the unit in place, push the panel
This jumper is used to select the proper input range. The input range selected
To remove the rear cover, locate the cover locking tab below the 2nd and 3rd
DS ON
Working Voltage: 150 Vrms
PTIONAL
Warning: Exposed line voltage exists on the circuit boards. Remove
WARNING: Disconnect all power to the unit before installing
: 0.7 V @ 100 mA
BEZEL
PANEL
GASKET
all power to the meter and load circuits before accessing inside of
the meter.
Plug-in card.
NSTALLING THE
ETTING THE
P
PANEL
LUG
-
NUT FASTENER
IN
J
MOUNTING CLIP
MOUNTING SCREW
UMPERS
C
M
ARDS
ETER
3
RS485 SERIAL COMMUNICATIONS CARD
RS232 SERIAL COMMUNICATIONS CARD
USB PROGRAMMING CARD
The panel latch should be engaged in the farthest forward slot possible. To
achieve a proper seal, tighten the latch screws evenly until the unit is snug in the
panel (Torque to approx. 28 to 36 in-oz [0.202 to 0.26 N-m]). Do not over-
tighten the screws.
INSTALLATION ENVIRONMENT
temperature and provides good air circulation. Placing the unit near devices that
generate excessive heat should be avoided.
Do NOT use solvents. Continuous exposure to direct sunlight may accelerate the
aging process of the bezel.
keypad of the unit.
V
Offstate Leakage Current: 0.5 mA max.
Type: RS485 multi-point balanced interface (non-isolated)
Baud Rate: 300 to 38.4k
Data Format: 7/8 bits; odd, even, or no parity
Bus Address: 0 to 99; max 32 meters per line
Transmit Delay: Selectable (refer to CUB5COM bulletin)
Type: RS232 half duplex (non-isolated)
Baud Rate: 300 to 38.4k
Data Format: 7/8 bits; odd, even, or no parity
Type: USB virtual comms port
Connection: Type B
Baud Rate: 300 to 38.4k
Unit Address: 0 to 99
The unit should be installed in a location that does not exceed the operating
The bezel should only be cleaned with a soft cloth and neutral soap product.
Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to operate the
DS MAX
: 30 VDC
MAIN CIRCUIT
BOARD
2.68
(68
+.8
-.0
+.025
-.000
)
INPUT RANGE JUMPERS
200mA
JUMPER LOCATIONS
2mA
1.30
INPUT RANGE
(33
+.6
-.0
+.024
-.000
)
200µA
20mA