No. Of Digits / Alpha
6
Digit Height
8.8mm
Mounting Type
Base
Lead Free Status / RoHS Status
na
- Current page: 121 of 273
- Download datasheet (16Mb)
OUTPUT OPERATING MODES
DPDT - OFF Time First
DPDT - ON Time First
Overlapping Intervals
MOUNTING
The SX110 timer uses two removable mounting clips with adjustable screws to mount the enclosure in a panel as shown below.
ORDERING INFORMATION
Both outputs are energized together. The OFF time defined by
Setpoint 1 (SEt1) occurs first.
Both outputs are energized together. The ON time defined by
Setpoint 1 (SEt1) occurs first.
Output 1 is ON first. Output 2 is normally energized at the end of the
Output 1 timing interval. The Output 2 timing interval can be
programmed to begin before the end of the Output 1 interval by
using Setpoint 3 (SEt3). Setpoint 3 is the amount of time before the
end of the Output 1 interval that the Output 2 interval is started. In
repeat operation, Output 1 is energized again at the end of the
Output 2 interval.
OUTPUT 2
OUTPUT 1
OUTPUT 2
OUTPUT 1
OUTPUT 1
OUTPUT 2
and
and
(75.69)
2.98
SET 1
SET 1
OUTPUT TYPE
(75.69)
SET 1
2.98
Sym.
10
SET 3
SET 2
SET 2
SET 2
Relay Output
Description
SET 1
SET 1
SET 2
SET 2
SX1
PANEL CUTOUT
SQUARE
2.72
(68
+0.7
-0.0
+0.028
-0.000
)
10
Non-Overlapping Intervals
TERMINAL ASSIGNMENTS
Terminals 6, 7, and 11 are not used on the SX110 timer.
(5.84)
0.23
Output 1 is ON first. Output 2 is normally energized at the end of the
Output 1 timing interval. The Output 2 timing interval can be pro-
grammed to begin a delay or dwell period after the end of the Output 1
interval by using Setpoint 3 (SEt3). Setpoint 3 is the amount of time
after the end of the Output 1 interval that the Output 2 interval is started.
In repeat operation, the Setpoint 3 dwell period also occurs after the
Output 2 interval and before the Output 1 interval repeats.
OUTPUT 2
OUTPUT 1
VEEDER-ROOT • EAGLE SIGNAL • DYNAPAR
A6
yy
yy
yy
yy
VOLTAGE & FREQUENCY
yyy
yyy
yyy yy
OUTPUT 1
Sym.
yy
A6
PANEL THICKNESS (STEEL)
0.125 – 0.313 (3.125 – 7.825)
SET 1
120 VAC, 50/60 Hz
Description
(127.0)
SET 3
5.00
SET 2
OUTPUT 2
OFF
ON
1
SET 3
SWITCH
2
3
4
0.50 REQUIRED
FOR WIRING
5
6
7
8
5.27
T
O
T
A
Z
N
G
L
I
I
E
L
E
C
T
R
O
N
C
I
5
M
R
T
E
S
I
Related parts for 166736-006
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
![1667](/photos/21/57/215784/3812870_tmb.jpg)
Part Number:
Description:
POWER SUPPLY, BENCH, 60V
Manufacturer:
B&K Precision
Datasheet:
![A103-A12](/images/no-image3.png)
Part Number:
Description:
Module; Veeder-Root Brand, A103 Series; NEMA Approved; 10 to 20 VDC
Manufacturer:
Veeder-Root
Datasheet:
![A103-A16](/images/no-image3.png)
Part Number:
Description:
Module; Veeder-Root Brand, A103 Series; NEMA Approved; 10 to 20 VDC
Manufacturer:
Veeder-Root
Datasheet:
![0746025-001](/images/no-image3.png)
Part Number:
Description:
COUNTER, VEEDER-ROOT, SQ. CASE, RAT. DR., FLANGE MOUNT, 5 FIGS., #2 ROT.
Manufacturer:
Veeder-Root
Datasheet:
![EHM-100112](/images/no-image3.png)
Part Number:
Description:
HOUR METER, ROUND, 9-85VDC, BLADE TERMINALS, VEEDER-ROOT LOGO
Manufacturer:
Veeder-Root
Datasheet:
![0166736-006](/images/no-image3.png)
Part Number:
Description:
COUNTER, VEEDER-ROOT, RATCHET DRIVE, KNOB RESET, #3 ROT.
Manufacturer:
Veeder-Root
Datasheet:
![CM030121210](/images/no-image3.png)
Part Number:
Description:
MAX Count Series, 3 Solid State And 3 Relay Outputs
Manufacturer:
VEEDER ROOT
![HR625-1000-0241](/photos/19/89/198952/4582389_tmb.jpg)
Part Number:
Description:
Encoder
Manufacturer:
VEEDER ROOT
Datasheet:
![109888-0001](/images/no-image3.png)
Part Number:
Description:
Inductive Proximity Sensor
Manufacturer:
VEEDER ROOT
Datasheet:
![PBT03172](/images/no-image3.png)
Part Number:
Description:
TIMER ACCESSORY, SOCKET
Manufacturer:
VEEDER ROOT
Datasheet:
![0195316-051](/photos/21/39/213983/3774199_tmb.jpg)
Part Number:
Description:
Counter Display Panel
Manufacturer:
VEEDER ROOT
Datasheet:
![H220100100211](/images/no-image3.png)
Part Number:
Description:
Encoder, Bidirectional, Flange Mount
Manufacturer:
Veeder-Root
Datasheet: