101 013 SJSJ YOKOGAWA, 101 013 SJSJ Datasheet - Page 35

Voltage Meter

101 013 SJSJ

Manufacturer Part Number
101 013 SJSJ
Description
Voltage Meter
Manufacturer
YOKOGAWA
Datasheet

Specifications of 101 013 SJSJ

Meter Function
DC Voltmeter
Meter Range
0-600 V
Meter Size/dimensions
DB-14
Scale Length
6.9"
Meter Shape
Square
Voltage Meter Range
0-600 VDC
Display Accuracy ±
1%
Accuracy
+/- 1% Of FS
Barrel Size
3.97"
Meter Movement
Moving Coil
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
S W I T C H B O A R D I N S T R U M E N T S
34
Yokogawa’s JUXTA“AC POWER SERIES“ transducers (2469 & 2489)
are rugged metal case designs for utility and industrial applica-
tions. Most models are UL recognized under File E60579 and
exceed IEEE472/ANSI C37.90.1 Surge Withstand Capability test. The
“SWC” test assures maximum protection from damaging line tran-
sients caused by switchgear operation or lightning strikes
upstream on the system.
Power transducers provide an analog DC Voltage or Current out-
put proportional to an AC input. The input typically comes from
the secondary of potential and/or current transformers such as
*Note: Standard calibration is 500W or VARs per element. Otherwise, specify CT/PT ratios and primary WATTS/VARS relative to desired output
for a particular model.
W
U
N
O
G
Q
U
N
C
R
R
E
T
V
L
T
A
E
F
R
E
E
C
Y
A
T
T
S
V
A
R
S
*
*
0-1 mA output / self-powered/60 Hz
0-1 mA output / self-powered / rated 50/60 Hz
True rms / 0-1mA output / 120V auxiliary power
4-20mA output / 120V auxiliary power
True rms / 4-20mA output / 120V auxiliary power
3 in 1 transducer, 0-1mA output / self-powered
0-1 mA output / self-powered/rated 60 Hz
0-1 mA output / self-powered / rated 50/60 Hz
True rms / 0-1mA output / 120V auxiliary power
4-20mA output / 120V auxiliary power
True rms / 4-20mA output / 120V auxiliary power
3 in 1 transducer, 0-1mA output / self-powered
Frequency ± 1.0 Hz deviation, 0-1mA output
Frequency ± 1.0 Hz deviation, 4-20mA output
Frequency ± 2.0 Hz deviation, 0-1mA output
Frequency ± 2.0 Hz deviation, 4-20mA output
Frequency ± 5.0 Hz deviation, 0-1mA output
Frequency ± 5.0 Hz deviation, 4-20mA output
Frequency ± 10 Hz deviation, 0-1mA output
Frequency ± 10 Hz deviation, 4-20mA output
Watt 1P2W, 0-1mA output (1 Element)
Watt 1P2W, 4-20mA output (1 Element)
Watt 3P3W, 0-1mA output (2 Element)
Watt 3P3W, 4-20mA output (2 Element)
Watt 3P4W, 0-1mA output (2
Watt 3P4W, 4-20mA output (2
Watt 3P4W, 0-1mA output (3 Element)
Watt 3P4W, 4-20mA output (3 Element)
VAR 1P2W, 0-1mA output (1 Element)
VAR 1P2W, 12±8mA output (1 Element)
VAR 3P3W, 0-1mA output (2 Element)
VAR 3P3W, 12±8mA output (2 Element)
VAR 3P4W, 0-1mA output (2
VAR 3P4W, 12±8mA output (2
VAR 3P4W, 0-1mA output (3 Element)
VAR 3P4W, 12±8mA output (3 Element)
Input 120V, 5A AC, 60 Hz, self-powered
Input 120V, 5A AC, 60 Hz, self-powered
Standard transducer inputs / outputs
Input 120VAC, 60 Hz, self-powered
Input 0-5 Amp AC, 60 Hz
Input 0-150 VAC, 60 Hz
1
2
1
2
1
1
Element)
2
Element)
2
Element)
Element)
JUXTA P
OWER
150V and 5A AC. The output is linked to remote monitoring equip-
ment such as meters, recorders, PLC’s, SCADA or Energy
Management systems. For most industrial monitoring needs, 0.5%
accuracy is acceptable, and our 2469 Series exceeds this require-
ment. Most power utilities require a higher level of accuracy; and
our 2489 series is a superior choice for those applications.
Below, are the most popular models of both the 2469 and 2489
Power Transducers. For other input and output combinations, con-
nection drawings, specifications and other models, please request
catalog BU-JAC-05E.
T
RANSDUCERS
2469 (0.5% Accuracy)
2469 (0.5% Accuracy)
2469 (0.5% Accuracy)
2469 (0.5% Accuracy)
246961-540-AHF-0-M
246963-540-AHF-0-M
246964-540-AHF-0-M
246965-540-AHF-0-M
246961-540-AFB-0-M
246963-540-AFB-0-M
246964-540-AFB-0-M
246965-540-AFB-0-M
2469 (±2% Span)
246921-380-AHD-1
246931-380-AHD-1
246922-330-AHD-1
246932-330-AHD-1
246982-320-AHD-0
246983-320-AHD-0
246984-320-AHD-0
246985-320-AHD-0
246951-540-AHD-0
246953-540-AHD-0
246954-540-AHD-0
246955-540-AHD-0
246921-380-AFA-0
246921-382-AFA-0
246931-380-AFA-1
246923-380-AFA-0
246922-330-AFA-0
246922-332-AFA-0
246932-330-AFA-1
246924-330-AFA-0
246982-320-AFA-0
246983-320-AFA-0
246984-320-AFA-0
246985-320-AFA-0
246951-540-AFA-0
246953-540-AFA-0
246954-540-AFA-0
246955-540-AFA-0
Model type
2489 (0.2% Accuracy)
2489 (0.2% Accuracy)
2489 (0.2% Accuracy)
2489 (0.2% Accuracy)
2489 (±0.2% Span)
248961-540-AHF-0-M
248963-540-AHF-0-M
248964-540-AHF-0-M
248965-540-AHF-0-M
248961-540-AFB-0-M
248963-540-AFB-0-M
248964-540-AFB-0-M
248965-540-AFB-0-M
248921-380-AHD-1
248931-380-AHD-1
248922-330-AHD-1
248932-330-AHD-1
248982-320-AHD-0
248983-320-AHD-0
248984-320-AHD-0
248985-320-AHD-0
248951-540-AHD-0
248953-540-AHD-0
248954-540-AHD-0
248955-540-AHD-0
248921-380-AFA-0
248921-382-AFA-0
248931-380-AFA-1
248923-380-AFA-0
248922-330-AFA-0
248922-332-AFA-0
248932-330-AFA-1
248924-330-AFA-0
248982-320-AFA-0
248983-320-AFA-0
248984-320-AFA-0
248985-320-AFA-0
248951-540-AFA-0
248953-540-AFA-0
248954-540-AFA-0
248955-540-AFA-0
Model type

Related parts for 101 013 SJSJ