EM21-72D.AV5.3.X.0.SX CARLO GAVAZZI, EM21-72D.AV5.3.X.0.SX Datasheet

no-image

EM21-72D.AV5.3.X.0.SX

Manufacturer Part Number
EM21-72D.AV5.3.X.0.SX
Description
METER, ENERGY, MODBUS
Manufacturer
CARLO GAVAZZI
Datasheet

Specifications of EM21-72D.AV5.3.X.0.SX

Power Rating
1W
Meter Function
Energy Management
Meter Size/dimensions
72mm X 72mm X 65mm
Display Technology
Removable LCD
External Depth
65mm
External Length / Height
72mm
External Width
72mm
Ip/nema
RoHS Compliant
Svhc
No SVHC (15-Dec-2010)
Rohs Compliant
Yes
Energy Management
Energy Meter
Type EM21 72D
Output 2
X (*):
S (**): RS485 port
• Certified according to MID Directive, Annex "B"
Product Description
Three-phase energy meter
with removable front LCD
display unit. The same unit
can be used either as a
DIN-rail mounting or a pan-
el mounting energy meter.
This general purpose three-
phase energy meter is suit-
able for both active and
reactive
for cost allocation but also
for main electrical parame-
ter
retransmission (transducer
function). Housing for DIN-
rail
Type Selection
Range codes
AV5 (*): 400V
AV6 (**):120V
Specifications are subject to change without notice
"Type examination" relevant to active electrical energy
Certified according to MID Directive, Annex "B"
+ Annex "F" for legal metrology relevant to active
electrical energy meters (see Annex MI-003), see
option “PF” below.
meters (see Annex MI-003), see option “P” below
mounting
measurement
None
1(6)A (***)
(CT connection)
5(6)A or 1(6)A (***)
(VT/PT and
CT connections)
energy
LL
LN
AC, 5(6)A or
/230V
with
metering
LL
AC
IP50
and
Output 1
O (*):
(front)
Current measurements car-
ried out by means of exter-
nal
and voltage measurements
carried out either by means
of direct connection or by
means of potential trans-
formers. EM21-72D is pro-
vided, as standard, with a
pulsating output for active
energy retransmission. In
addition a 2-wire RS485
communication
available as an option.
System
3 (*): balanced and
current
unbalanced load:
3-phase, 4-wire;
3-phase, 3-wire;
2-phase, 3-wire;
1-phase, 2-wire
Single static output
(opto-mosfet)
protection
transformers
EM2172D DS ENG 190210
port
degree.
is
• Class B (kWh) according to EN50470-3
• Class 1 (kWh) according to EN62053-21
• Class 2 (kvarh) according to EN62053-23
• Accuracy ±0.5 RDG (current/voltage)
• Energy meter
• Instantaneous variables readout: 3 DGT
• Energies readout: 6+1 DGT
• System variables: W, var, PF, Hz, Phase-sequence.
• Single phase variables: V
• Energy measurements: total kWh and kvarh
• TRMS measurements of distorted sine waves
• Self power supply
• Dimensions: 4-DIN modules and 72x72mm
• Protection degree (front): IP50
• Application adaptable display and programming
• Easy connections management
• Detachable display
• Multi-use housing: for both DIN-rail and panel
How to order EM21 72D AV5 3 X O X X
Model
Range code
System
Power supply
Output 1
Output 2
Option
Power supply
X (*): Self power supply
(*) as standard.
(**) on request.
(***) the range 1(6)A
is available but not in
compliance with the
EN50470-3 standard.
(voltages/currents)
procedure (Easyprog function)
mounting applications
from 18V to 260VAC
VLN, 45 to 65 Hz
(connection VL1-N)
LL
, V
Options
X (*):
P:
PF:
LN
, A, PF
None
Certified according
to MID Directive,
Annex "B" "Type
examination" relevant
to active electrical
energy meters (see
Annex MI-003) (*)
Certified according
to MID Directive,
Annex "B" + Annex
"F" for legal metrolo-
gy relevant to active
electrical energy
meters (see Annex
MI-003) (**)
1

Related parts for EM21-72D.AV5.3.X.0.SX

EM21-72D.AV5.3.X.0.SX Summary of contents

Page 1

... Protection degree (front): IP50 • Application adaptable display and programming procedure (Easyprog function) • Easy connections management • Detachable display • Multi-use housing: for both DIN-rail and panel mounting applications How to order EM21 72D AV5 Model protection degree. Range code System current ...

Page 2

... TRMS measurements of distorted wave forms. By means of external CT’s. In 5A: ≤3 (15A max. peak). 6A, @ 50Hz. 120A, @ 50Hz. 1 < 0.3VA Power consumption: <2VA Hz. Two push buttons for vari- able selection and pro- gramming of the instru- ment working parameters. EM2172D DS ENG 190210 ...

Page 3

... Driver input capability Insulation Transformer ratio VT (PT) CT 3-phase (4-wire) Displaying Reset Easy connection function EM2172D DS ENG 190210 on the instrument. 247, selectable by means of the front keypad MODBUS/JBUS (RTU) System and phase vari- ables: see table “List of variables...” All the configuration parameters. ...

Page 4

... DIN43864, IEC62053-31 CE, cULus listed Screw-type 2.4 x 3.5 mm Min./Max. screws tighten- ing torque Noryl PA66, self-extinguishing V-0 Panel and DIN-rail IP50 IP20 Approx. 400 g (packing included) ≤2VA/1W Communication port Self power supply 4kV 0kV - 4kV - 4kV 4kV - EM2172D DS ENG 190210 ...

Page 5

... Operating temperature EMC compliance System variables Equivalent three-phase voltage Voltage asymmetry Three-phase active power Three-phase apparent power EM2172D DS ENG 190210 Percentage error limits 0.1A 0.25A 0.25A 0. Accuracy limits (Reactive energy) Start-up current: 10mA max: 6A. -25°C to +55°C (-13°F to 131° ...

Page 6

... Specifications are subject to change without notice 3-ph. 4-wire 3-ph. 3-wir unbalanced unbalanced Notes system system x x Total x x Total x x sys=system (∑ sys=system (∑ sys=system (∑ sys=system (∑ sys=system (∑ sys=system (∑ Applications Note the quadrant the quadrant EM2172D DS ENG 190210 ...

Page 7

... Full set of available variables can be displayed By means of the patented detachable display it is possi- ble to configure the same instrument either as a panel mounting meter or... EM2172D DS ENG 190210 note Year of production and firmware release KWh per pulse of the LED System type and connection type ...

Page 8

... Specifications are subject to change without notice 3-ph, 4-wire, unbalanced load Fig 3-CT and 3-VT/PT connections 3-ph, 3-wire, unbalanced load Fig (*) 2-CT connections (ARON) 3-ph, 3-wire, balanced load Fig (*) 1-CT and 2-VT/PT connections EM2172D DS ENG 190210 ...

Page 9

... Specifications are subject to change without notice 2-ph, 3-wire Fig 2-CT and 2-VT/PT connections Static output wiring diagram Opto-mosfet VDC/AC 17 VDC/AC supply EM2172D DS ENG 190210 (6A) System type selection: 1P 1-ph, 2-wire Fig 1-CT connection 18 9 ...

Page 10

... Red LED blinking proportional to the energy being 1 measured. 3. Display 2 LCD-type with alphanumeric indications to display all the 1 measured variables. 4. Connections Screw terminal blocks for instrument wiring. 5. Green LED Lit when power supply is available 4 Specifications are subject to change without notice 68x68mm -0 +0.7mm EM2172D DS ENG 190210 ...

Related keywords