E242-89V-G-NP-NP Tyco Electronics, E242-89V-G-NP-NP Datasheet - Page 7

METER, DIN48, 40VDC

E242-89V-G-NP-NP

Manufacturer Part Number
E242-89V-G-NP-NP
Description
METER, DIN48, 40VDC
Manufacturer
Tyco Electronics
Datasheet

Specifications of E242-89V-G-NP-NP

Power Rating
4.5VA
Terminal Resistance Range
1kohm
Meter Function
Voltage
Meter Range
0Vdc To 40Vdc
Meter Size/dimensions
48mm X 48mm X 53mm
Scale Length
42mm
External Depth
64mm
External Length /
RoHS Compliant
Catalogue Numbering System
Guide to Catalogue Numbering System – Example Code: 244 – 03AG – LSPK – C6 – ER
SERIES
016 – Fiesta
075 – Short-case switchboard
077 – Standard switchboard
078 – Hi-shock sealed
079 – 8
083 – 2" sealed
084 – 2
242 – 48mm DIN
243 – 72mm DIN
244 – 96m DIN
246 – 144mm DIN
E242 – 48mm short-scale
E243 – 72mm short-scale
E244 – 96mm short-scale
3
1
/
/
4
2
" switchboard
" sealed
244
MOVEMENT CODE
01
02
03
05
07
08
10
11
12
13
14
15
16
21
30
31
41L – Frequency meter
41S – Frequency meter
42
45
92
94
HW – Kilowatt hour class 1.0
KH
KW – Kilowatt hours class 2.0
– Short-scale AC and DC
– Short-scale AC
– Long-scale AC and DC
– Long-scale AC and DC
– Edgewise AC DC
– Long-scale AC
– Edgewise AC and DC
– Long-scale DC
– Phase sequence meter
– 360 rotating iron PFI
– Synchroscope
– Elapsed time meter
– Thermal demand
– Wattmeter
– Meter relay
– VArmeter
– Power factor meter
– RTD temperature
– Shunts
– Current transformers
– Kilowatt hours
ammeter
long-scale
short-scale
03
TYPE / FUNCTION
A – Amperes DC
B – Rectified amperes
C – Center zero amps
D – Zero offset current
F
G – Volts AC
H – High middle
K
L
N – Center zero voltage
P
R – Live zero current
S
V
W – Rectified voltage
Y
Z
2
3
5
6
8
9
– Amperes AC
– DC input non electrical
– VAr self contained
– Zero offset voltage
– Live zero voltage
– Volts DC
– Expanded scale AC
– Expanded scale DC
– 2 x overload ammeters
– 3 x overload ammeters
– 1-phase 2-wire watts
– 6 x overload ammeters
– 3-phase 3-wire watts
– 3-phase 4-wire watts
scaling
A
NATIONAL STANDARD
A – ANSI C39.1
B – BS 89
G – DIN
I
J
This guide is not inclusive of all catalogue numbers and should be
used for reference only, as improper combinations can be achieved.
– ANSI fixing captions
– Japanese instrument
Standard
G
INPUT OR
MOVEMENT RATING
LA
LS
PZ
RX
SJ
PN
RP
SE
QQ – 120V 5A
QS – 240V 5A
QT
– 1A
– 5A
– 150V
– 300V
– 600V
– 120V
– 240V
– 480V
– 480V 5A etc
LS
SCALING OR OUTPUT
BX
FA
HG – 4/20mA
PK
PZ
RL
RX
SC
SJ
SS
TM – 0/2000
UB – 0/4000
UJ
– Volt free relay contacts
– 1mA
– 0/100
– 0/150
– 0/200
– 0/300
– 0/400
– 0/600
– 0/1000
– 0/5000 etc
PK
SYSTEM
FREQUENCY
(AC Meters)
C4
C5
C6
C7
– 400Hz
– 50Hz
– 60Hz
– 50/60Hz
C6
OPTIONS
Indicate as
required
ER
83