35074 Simpson, 35074 Datasheet - Page 57
35074
Manufacturer Part Number
35074
Description
Current Meter
Manufacturer
Simpson
Type
Ammeterr
Specifications of 35074
Meter Function
AC Ammeter
Meter Range
0A To 25A
Meter Size/dimensions
3.5 In.
Scale Length
79.9mm
Meter Shape
Rectangular
Display Accuracy ±
2%
Current Meter Range
0-25 A
Accuracy
+/-2 %
Barrel Size
2.79"
Connection Type
Stud
Diameter, Body
2.73 in.
Diameter, Mounting Hole
0.128 in.
Dimensions
3.25"L×3.25"H
Display Type
Analog
Function
Ammeter
Impedance
0.008 Ohms @ 60 Hz
Material, Casing
Plastic
Measuring Range
0 to 25 ACA
Primary Type
Electromechanical
Range, Measurement
0 to 25 AAC
Repeatability
2%
Size
3-1⁄2 in.
Size, Thread
1⁄4-28
Special Features
Extended Operatiing Temp
Standards
UL Recognized
Temperature, Operating
-20 to +65 °C
Tracking
±3%
Response Time
1.5 Seconds Maximum
Equipment Type
AC Current Meter
Range
0 - 25
Meter Movement
Iron-Vane
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
35074-8001
Manufacturer:
MOLEX
Quantity:
44 663
Company:
Part Number:
35074-8001
Manufacturer:
TE
Quantity:
35 000
Company:
Part Number:
35074-9002
Manufacturer:
MOLEX
Quantity:
15 600
• Wide Variety of Control, Alarm, and Limit
• Calibration Not Affected by Steel Panel
• Rugged Metal Case for Rigorous Environments
• Commercially-Sealed, Moisture and Dust
Dimensions
Use
Mounting
Proof
4 - 1/2”-Model 3344AIXA & 3324AIXA
1
=
Panel Meter Cut-out Dimensions
Specifications
Accuracy:
Movement:
Suspension:
Tracking:
Repeatability:
Shielding:
Response Time:
Overload (1 sec.):
Overload (Continuous):
Dial:
Case:
Voltage Drop:
Pointer:
Scale Length:
Net Weight:
Control Point(s)
Adjustments:
Switching:
Differential:
Auto/Manual Reset:
Contacts/Output Relay:
Frequency Response:
Power:
Operating Temperature:
Circuit-to-Ground
Voltage:
NOTE:
3 - 1/2”-Model 3343AIXA & 3323AIXA
AC: ±3% of full scale; DC: ±2% F.S.
Annular, self-shielding
Pivot and jewel
±3%
Within 0.5% F.S.
Calibration is unaffected by magnetic panel mounting
1.5 seconds maximum above 10mA
AC: 7 amps; DC: 10 times F.S.
AC: 7 amps, DC: 1.5 times F.S.
Sharp clear scale. Each dial arc is calibrated to
track the specific type of movement used.
Sealed metal, plastic window
50mV
Black, knife-edge
4.05" (103.0mm)
17oz (0.48kg)
Single, high limit, 0-100% of arc; double, low limit 0-
95% of arc; high limit 5-100% of arc Adjustable to
within 4° of each other
Within 1% of indication
“On,” “Off” difference is within 0.5% of F.S.
Latching function can be enabled independently
for each relay by removing jumpers on terminal
block
DPDT relay contacts for each control point; Each
set of contacts rated at 5 amps, 120/240 VAC resistive.
50-1000Hz
108-132 VAC, 50-400Hz
+41°F to 122°F (5°C to +50°C)
250V rms maximum
DC meters meet ANSI specification C-39.1
29
B