EM32-1B LASCAR, EM32-1B Datasheet - Page 4

VOLTMETER, LCD, 3.5DIGIT

EM32-1B

Manufacturer Part Number
EM32-1B
Description
VOLTMETER, LCD, 3.5DIGIT
Manufacturer
LASCAR
Datasheet

Specifications of EM32-1B

Supply Voltage Range
3.5V To 6.5V / 7.5V To 14V
No. Of Digits / Alpha
3.5
Panel Cutout Height
23.5mm
Operating Temperature Range
0°C To +50°C
Svhc
No SVHC (18-Jun-2010)
Display Technology
LCD
Operating
RoHS Compliant
Accuracy %
0.1%
Rohs Compliant
Yes
Character Height
8mm
Specifications liable to change without prior warning
Measuring a single ended input
voltage referenced to supply, i.e. the
input voltage and the meter's power
supply share the same 0V rail.
Ensure jumper link J1 is not fitted.
Ensure jumper link J2 is not fitted.
Measuring a single ended input
voltage referenced to supply, i.e. the
input voltage and the meter's power
supply share the same 0V rail.
Ensure jumper link J1 is not fitted.
Ensure jumper link J2 is fitted.
SCALING
Two resistors Ra and Rb
may be used to alter the
full scale reading (FSR) of
the meter - see table. The
meter will have to be re-
calibrated by adjusting the
calibration potentiometer
on the rear of the module.
APPLICATIONS
Do not connect more than one meter to the same power supply if the meters cannot use the same signal
ground. Taking any input beyond the power supply rails will damage the meter.
5V supply operation
9V supply operation
±200mV
±200mV
+3.75 to +7.0V
+
+
+3.5 to +6.5V
-
-
-3.75 to -7.0V
IHI
IHI
ILO
ILO
V+
0V
V+
0V
(3.5 to 6.5V Meter Power Supply)
(7.5 to 14.0V Meter Power Supply)
0V
*Ensure that Ra is rated for high voltage use.
Voltage
Current
Vin
Iin
Measuring an input voltage referenced to
a floating supply, i.e. the input voltage
and the meter's power supply are isolated
from each other.
Ensure jumper link J1 is fitted.
Ensure jumper link J2 is not fitted.
Measuring an input voltage referenced to
a floating supply, i.e. the input voltage
and the meter's power supply are isolated
from each other.
Ensure jumper link J1 is fitted.
Ensure jumper link J2 is not fitted.
±200mV
±200mV
www.lascarelectronics.com
+
+7.5 to +14.0V
+
-
-
+3.5 to +6.5V
2000V*
200mA
200 A
20mA
200V
2mA
20V
FSR
2V
EM32-1B
Round Hole Mounting LCD Voltmeter
910k
1M
1M
1M
0R
0R
0R
0R
Ra
IHI
ILO
IHI
ILO
V+
0V
V+
0V
100k
100R
100R
10k
10R
Rb
1R
1k
1k
L1 =
L1 =
Issue 2
0V
0V
March/2003
Vin or in
Measuring a current from a circuit which is
floating with respect to the meter's supply,
i.e. the current and the meter's power
supply are isolated from each other.
Ensure jumper link J1 is fitted.
Ensure jumper link J2 is not fitted.
Measuring a current from a circuit which is
floating with respect to the meter's supply,
i.e. the current and the meter's power
supply are isolated from each other.
Ensure jumper link J1 is fitted.
Ensure jumper link J2 is not fitted.
+
-
I
I-
I
I-
I
+
+
Ra
Rb
Rb
+7.5 to +14.0V
+3.5 to +6.5V
M.C.
Rb
Applies to EM32-1B/2
IHI
ILO
EM32-1B
IHI
ILO
IHI
ILO
Page 4 of 4
V+
V+
0V
0V
Page 4 of 4
Page 4 of 4
0V
0V

Related parts for EM32-1B