DPM8100A-2 ANDERS ELECTRONICS, DPM8100A-2 Datasheet - Page 2

DPM, LED, DIN, DC VOLTMETER

DPM8100A-2

Manufacturer Part Number
DPM8100A-2
Description
DPM, LED, DIN, DC VOLTMETER
Manufacturer
ANDERS ELECTRONICS
Datasheet

Specifications of DPM8100A-2

Supply Voltage Range
184VAC To 253VAC
No. Of Digits / Alpha
3.1/2
Panel Cutout Height
45mm
Panel Cutout Width
92mm
Operating Temperature Range
0°C To +50°C
Display Technology
LED
External
RoHS Compliant
R30
8100, 8120, 8140
8400, 8420
8100, 8120, 8140
8400, 8420
8100A, 8120A
8400A, 8420A
8100A, 8120A
8400A, 8420A
8100, 8120, 8140
8400, 8420
8100, 8120, 8140
8400, 8420
8100A, 8120A
8400A, 8420A
8100A, 8120A
8400A, 8420A
8100, 8120, 8140
8400, 8420
8100, 8120, 8140
8400, 8420
8100, 8120, 8140
8400, 8420
8100, 8120, 8140
8400, 8420
VR1
R17
MODEL NUMBER
RANGE SPECIFICATION
PCB LAYOUT
ADJUST
Hi
In
1
!
Make
from pin 4 to
earth
conditions.
SPAN
Warning:
Lo
In
2 3
N/c
under any
LINK
no
JP1
0v
dc
A to D Converter Chip
4 5
connection
Hold
R18
i/p
mains
+5V
6
(of range required)
dc
RESOLUTION
100mV
100mV
100 A
100 A
100 V
100 V
100 V
0.1 A
10 V
0.1 A
10mV
10mV
10mV
10nA
10 A
10 A
1mA
1mV
1mV
1mV
1mV
1 A
1 A
1V
anders
Tel: +44 (0)20 7380 8167 Fax: +44 (0)20 7874 1908 http://www.anders.co.uk
230
Vac
Important
Observe the mains
input connections
7
OFFSET
addition.
115
Vac
8 9
electronics plc
SENSITIVITY
Vac
0
JP2
200mV
200mV
200mV
200mV
200mV
200mV
200mV
200mV
VR2
BASIC
VR2
F1
2V
2V
2V
2V
1
3
2
Decimal point
DIP switch
on 4.5 digit
models
Decimal point
select jumper
on 3.5 digit
models
Zero offset
adjust (where
fitted)
Power supply
i n p u t f u s e
100mA rated
(see Note 6)
(see note 2)
REQUIRED
200mA
200 A
20mA
RANGE
200V
0.2V
2mA
20V
20V
2A
Bayham Place, London NW1 OEU UK
2V
2V
650V
2
3
4
5
6
1
PROTECTION
(SEE NOTE 5)
DISSIPATION
OVERLOAD
RATING OF
NOTES
RESISTOR
200mV and
To measure voltages above the meters basic sensitivity, attenuator
resistors R17 and R18 need to be installed. The general equation to
determine their values is given by: V
Where V is the input voltage required and V is the corresponding
display voltage. Note, V max is actually 199.9mV for a nominal
200mV basic sensitivity meter and 1.999V for a nominal 2V meter
Examples
For standard input ranges choose the corresponding resistors from
the range specification table below.
For inputs greater than 200V, R17 must be a high voltage resistor
such as Philips VR37 Series (1x2M2, 0.5W, RS164-8316) with
R18=2k2 Alternatively, use two carbon film resistors in series, such as
Multicomp MCF (2x1M2, 0.5W, Farnell 262-195) with R18 as 2K4.
See the options for R17 below. The maximum input voltage on this
range with correct resistors is 650V.
For ranges of 200V or less, for R17, use metal film resistors, 1%, 0.5W
as Farnell 545-314. For basic 200mV use only existing link JP1
For R18, on all voltage ranges, use metal film resistors, 1%, 0.25W
On current ranges, use metal film resistors, 0.5W for R30. The current,
using internal shunt resistor R30 must not exceed 2 Amps. Leave link
JP1 in place
The power supply input protection fuse is a 20mm cartridge type rated
at 250V / 100mA.
EXCEED
DO NOT
SHUNT
Link JP1
current
100V
100V
300V
100V
100V
300V
700V
R17
RC
IN
20V
10V
V
Ranges below
IN
R17
Options for Resistor R17
1M
1M
1M
1M
2M2
Metal film
resistor
200V
R17
1500rpm
Display
19.99V
D
110K
110K
R18
10K
10K
2K2
1.999V
0R1
1R
10R
1K
100R
1.5V
R30
V
Voltage resistor
D
IN
Single Hi
=
R17
R
1M
1M
LINK
Ranges above 200V
OUT
OUT
OUT
OUT
OUT
JP1
V x (1 + R / R )
17
IN
IN
IN
IN
IN
IN
IN
D
D
110K
176K
R
IMPEDANCE
18
DP8000-2 Rev3 10/03
film resistors
Two carbon
17
INPUT
R1 (0.1)
>I00M
>I00M
IOOR
2M2
IOR
Solder
R17
1M
IM
IM
IM
IR
Ik
18

Related parts for DPM8100A-2