LPAX0500 Red Lion Controls, LPAX0500 Datasheet - Page 2

Multifunction Meter

LPAX0500

Manufacturer Part Number
LPAX0500
Description
Multifunction Meter
Manufacturer
Red Lion Controls
Type
Multi-Functionr
Datasheet

Specifications of LPAX0500

No. Of Digits / Alpha
5
Panel Cutout Height
3.63"
Panel Cutout Width
9.29"
Signal Input Type
Current, Process, Strain Gage, Thermocouple, Voltage
Connection Type
Cage-Clamp
Cut Out, Panel
9.29×3.63 "
Digit Height
4
Dimensions
10"L×4.77"W×4.75"H
Display Digit Height
1.5 "
Display Type
LED
Function
Ammeter/Process/Resistance/Strain Gage/Temperature/Voltage
Material, Casing
Steel
Number Of Digits
6
Primary Type
Electronic
Range, Measurement
-19999 to 99999
Termination
Cage Clamp
Voltage, Input
85 to 250 VAC
Voltage, Supply
85 to 250 VAC/11 to 36 VDC or 24 VAC
Sealing
NEMA 4/IP65
Character Size
1.5"
Color
Red
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
Red Lion MPAXD000, MPAXH000, MPAXP000 And MPAXT000 MPAX Modules
7. ENVIRONMENTAL CONDITIONS:
8. MOUNTING REQUIREMENTS:
9. MODULE INSTALLATION:
About the MPAX Input Modules
scaling which allows the LPAX to display most any engineering unit. Once the MPAX is inserted into the LPAX, the unit has the same functions and capabilities of
our PAX Series Intelligent Panel Meters. A full set of PAX programming instructions will be included with the MPAX Module.
Note: The MPAX provides the operating power for the LPAX, therefore you must select either the AC or DC MPAX corresponding with your application and available
Selecting Your Display Components
Please use the following chart to identify the appropriate MPAX Module (including supply power) and LPAX Display that will satisfy your application.
OPTIONAL PLUG-IN CARDS AND ACCESSORIES
Adding Option Cards
However, only one card from each function type can be installed at a time. The
function types include Setpoint Alarms (PAXCDS), Communications
(PAXCDC), and Analog Output (PAXCDL). The cards can be installed initially
or at a later date. Each optional plug-in card is shipped with installation and
programming instructions.
COMMUNICATION CARDS (PAXCDC)
series. Only one of these cards can be installed at a time. When programming
the unit via Crimson, a Windows
must be used.
SETPOINT CARDS (PAXCDS)
these cards can be installed at a time. (Logic state of the outputs can be reversed
in the programming.) These plug-in cards include:
Operating Temperature Range: Determined by the MPAX module
Storage Temperature Range: -40 to 60°C
Operating and Storage Humidity: 0 to 85% max. RH (non-condensing)
Altitude: Up to 2000 meters
Max. panel thickness is 0.375" (9.5 mm)
Min. panel thickness for NEMA 4/IP65 sealing is 0.060" (1.57 mm)
24-pin shrouded connector on LPAX engages connector on MPAX module
upon installation. Shroud ensures proper alignment by providing a lead-in for
the module connector.
The MPAX Module serves as the input to the LPAX Display. There are several different modules to cover a variety of inputs. The MPAX module provides input
power.
To build a complete display unit, you will need an LPAX and an MPAX Input Module. The LPAX is only a display and will not operate without an MPAX Module.
The MPAX series meters can be fitted with up to three optional plug-in cards.
A variety of communication protocols are available for the PAX and MPAX
*Units available in various connector configurations.
The MPAX series has four setpoint alarm output plug-in cards. Only one of
PAXCDS10 - Dual Relay, FORM-C, Normally open & closed
PAXCDS20 - Quad Relay, FORM-A, Normally open only
PAXCDS30 - Isolated quad sinking NPN open collector
PAXCDS40 - Isolated quad sourcing PNP open collector
Universal DC Inputs
Process Inputs
Temperature Inputs
Strain Gage/ Load Cell
True RMS AC
Voltage/Current
PAXCDC1* - RS485 Serial
PAXCDC2* - RS232 Serial
PAXCDC30 - DeviceNet
WARNING: Disconnect all power to the unit before
SIGNAL TYPE
*For detailed Module specifications, see corresponding PAX literature. (i.e. For MPAXD specifications, see the PAXD literature)
installing Plug-in cards.
DC Voltage 200 mV, 2 V, 20 V, 300 V
DC Current 200 µA, 2 mA, 20 mA, 200 mA, 2 Amp
Resistance 100 ohm, 1000 ohm, 10 K ohm
0-20 mA or 0-10 VDC
Thermocouples-T, E, J, K, R, S, B, N, C, or Custom Scaling
RTD’s-100 ohm Pt (platinum) 385/392, 120 ohm Nickel 672, or
10 ohm Copper 427
24 mV or 240 mV
AC Voltage 200 mV, 2 V, 20 V, 300 V
AC Current 200 uA, 2 mA, 20 mA, 200 mA, 5 Amp
®
based program, the RS232 or RS485 Cards
PAXCDC4* - Modbus
PAXCDC50 - Profibus-DP
INPUT RANGES
2
10. CONNECTIONS: All wiring connections are made to the MPAX module
11. CONSTRUCTION: Steel front panel, enclosure, and rear cover with
12. WEIGHT: 2.7 lbs (1.2 kg) (less module)
LINEAR DC OUTPUT (PAXCDL)
from the analog output plug-in card. The programmable output low and high
scaling can be based on the input, max, min, or total display value. Reverse
slope output is possible by reversing the scaling point positions.
UNITS LABEL (LX)
label. The units label is applied directly to the panel in the embossed area. The
units backlight is then turned on via programming.
a list of available units labels.
PROGRAMMING SOFTWARE (CRIMSON)
LPAX meter from a PC. Crimson offers standard drop-down menu commands,
that make it easy to program the LPAX meter. The LPAX program can then be
saved in a PC file for future use. A PAX serial plug-in card is required to
program the meter using the software.
via high compression cage-clamp terminal blocks. Wiring instructions are
provided with the MPAX module.
textured black polyurethane paint for scratch and corrosion resistance
protection. Sealed front panel meets NEMA 4/IP65 specifications for indoor
use when properly installed. Installation Category II, Pollution Degree 2.
Panel gasket and keps nuts included.
Either a 0(4)-20 mA or 0-10 V retransmitted linear DC output is available
The LPAX Display has an area on the front panel designed for a custom units
Available on 5-digit version only. Refer to the LPAX Accessories Bulletin for
Crimson is a Windows
PAXCDL10 - Retransmitted Analog Output Card
CAUTION: DISCONNECT ALL POWER BEFORE
INSTALLING OR REMOVING MODULE
MPAXD000
MPAXP000
MPAXS000
MPAXH000
MPAXT000
85-250 VAC
MPAX MODULES
®
based program that allows configuration of the
11 to 36 VDC/ 24 VAC
MPAXD010
MPAXP010
MPAXT010
MPAXS010
*
N/A
LPAX DISPLAYS
LPAX0500
LPAX0500
LPAX0500
LPAX0500
LPAX0500

Related parts for LPAX0500