Y92S-29 Omron, Y92S-29 Datasheet - Page 3

no-image

Y92S-29

Manufacturer Part Number
Y92S-29
Description
Gasket
Manufacturer
Omron
Datasheets

Specifications of Y92S-29

Accessory Type
Waterproof Packing
For Use With
Digital Counter H7CZ Series
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
H5CL
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92S29
H5CL
Note: 1. The values are based on the set value.
Deviation of operating time and
setting error (including temperature
and voltage influences)
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
EMC
Case color
Weight
Characteristics
2. The value is applied for a minimum pulse width of 1 ms.
Item
Power start: 0.01% 0.05 s max. (see note 1)
Signal start: 0.005% 0.03 s max. (see note 1)
Signal start, at transistor output model: 0.005% 3 ms max. (see note 1 and 2)
If the set value is within the sensor waiting time (250 ms max.) in the case of power start, the
control output of the H5CL will not be turned ON until the sensor waiting time passes.
100 M min. (at 500 VDC) (between current-carrying terminal and exposed
non-current-carrying metal parts, and between non-continuous contacts)
2,000 VAC, 50/60 Hz for 1 min (between
current-carrying terminal and exposed
non-current-carrying metal parts)
1,000 VAC, 50/60 Hz for 1 min (between
non-continuous contacts)
3.0 kV (between power terminals)
4.5 kV (between current-carrying terminal and
exposed non-current-carrying metal parts)
square-wave noise by noise simulator (pulse
width: 100 ns/1 s, 1-ns rise)
Destruction:
Malfunction:
Destruction:
Malfunction:
Destruction:
Malfunction:
Operating:
Storage:
Operating: 35% to 85%
Mechanical:
Electrical:
(EMI):
Emission Enclosure:
Emission AC Mains:
(EMS):
Immunity ESD:
Immunity RF-interference:
Immunity Conducted Disturbance: ENV50141:
Immunity Burst:
Light gray (Munsell 5Y7/1)
Approx. 130 g
1.5 kV (between power terminals)
600 V (between input terminals),
H5CL-A
–10 to 55 C (–10 to 50 C if timers are mounted side by side) (with no icing)
–25 to 65 C (with no icing)
10 to 55 Hz, 0.75-mm single amplitude each in three directions
10 to 55 Hz, 0.5-mm single amplitude each in three directions
294 m/s
98 m/s
10,000,000 operations min.
100,000 operations min. (3 A at 250 VAC, resistive load)
15 kV
8 kV
(AC models)
2
2
(10G) each in three directions
(30G) each in three directions
EN50081-2
EN55011 Group 1 class A
EN55011 Group 1 class A
EN50082-2
EN61000-4-2:4 kV contact discharge (level 2)
ENV50140:
EN61000-4-4:2 kV power-line (level 3)
1,000 VAC, 50/60 Hz for 1 min (between
current-carrying terminal and exposed
non-current-carrying metal parts, and
between non-continuous contacts)
1.0 kV (between power terminals)
1.5 kV (between current-carrying terminal and
exposed non-current-carrying metal parts)
square-wave noise by noise simulator (pulse
width: 100 ns/1 s, 1-ns rise)
Approx. 110 g
480 kV (between power terminals)
600 V (between input terminals),
8 kV air discharge (level 3)
10 V/m (80 MHz to 1 GHz) (level 3)
10 V (0.15 to 80 MHz) (level 3)
2 kV I/O signal-line (level 4)
H5CL-AD
(DC models)
H5CL
3