Y92S-29 Omron, Y92S-29 Datasheet - Page 17

no-image

Y92S-29

Manufacturer Part Number
Y92S-29
Description
Gasket
Manufacturer
Omron
Datasheets

Specifications of Y92S-29

Accessory Type
Waterproof Packing
For Use With
Digital Counter H7CZ Series
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
H5CL
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92S29
Safety Precautions for All H7CZ Series (Common)
Do not allow pieces of metal, wire clippings, or fine
metallic shavings or fillings from installation to enter
the product. Doing so may occasionally result in
electric shock, fire, or malfunction.
Minor injury due to explosion may occasionally occur.
Do not use the Counter where subject to flammable or
explosive gas.
Fire may occasionally occur. Tighten the terminal
screws to the rated torque.
P2CF Socket terminals: 4.4 lb-in (0.5 N·m)
Minor injury due to electric shock may occasionally
occur. Do not touch any of the terminals while power
is being supplied. Be sure to mount the terminal cover
after wiring.
The life expectancy of the output relay varies
considerably according to its usage. Use the output
relay within its rated load and electrical life
expectancy. If the output relay is used beyond its life
expectancy, its contacts may become fused or there may be a
risk of fire. Also, be sure that the load current does not exceed
the rated load current and when using a heater, be sure to use a
thermal switch in the load circuit.
Minor electric shock, fire, or malfunction may
occasionally occur. Do not disassemble, modify, or
repair the Counter or touch internal components.
• The panel surface of the H7CZ is water-resistant (conforming to
• When mounting the Counter to a panel, tighten the two mounting
• Store the Counter at the specified temperature. If the Counter has
• Mounting the Counter side-by-side may reduce the life
• Use the Counter within the specified ranges for the ambient
• Do not use in the following locations:
• Do not use the Counter outside of the rated ranges for vibration,
• Do not use this Counter in dusty environments, in locations where
• Install the Counter well away from any sources of static electricity,
NEMA4, IP66, UL Type 4X (Indoor Use Only). To protect the
internal circuits from water penetration through the space between
the H7CZ and operating panel, waterproof packing is included.
Attach the Y92F-30 Adapter with sufficient pressure with the
reinforcing screws so that water does not penetrate the panel.
screws alternately, a little at a time, so as to keep them at an equal
tightness. If the panel screws are tightened unequally, water may
enter the panel.
been stored at a temperature of less than
−10°C, allow the Counter to stand at room temperature for at least
3 hours before use.
expectancies of internal components.
operating temperature and humidity.
• Locations subject to sudden or extreme changes in temperature.
• Locations where high humidity may result in condensation.
shock, water exposure, and oil exposure.
corrosive gasses are present, or in locations subject to direct
sunlight.
such as pipes transporting molding materials, powders, or liquids.
Precautions for Safe Use
0.5 to 1 mm
CAUTION
It is recommended that the
space between the screw
head and the Adapter be
0.5 to 1 mm.
• Internal elements may be destroyed if a voltage outside the rated
• Be sure that polarity is correct when wiring the terminals.
• Separate the Counter from sources of noise, such as devices with
• Do not connect more than two crimp terminals to the same
• Up to two wires of the same size and type can be inserted into a
• Use the specified wires for wiring. Applicable Wires: AWG 18 to
• Install a switch or circuit breaker that allows the operator to
• Approximately 14 V is output from the input terminals. Use a
• Use a switch, relay, or other contact so that the rated power supply
• Use a switch, relay, or other contact to turn the power supply OFF
• When changing the set value during operation, because the H7CZ
• When changing the comparison value during operation, because
• Do not use organic solvents (such as paint thinners or benzine),
• Confirm that indications are working normally, including the LCD.
• The waterproof packing may deteriorate, shrink, or harden
voltage range is applied.
input signals from power lines carrying noise, and wiring for I/O
signals.
terminal.
single terminals.
AWG 22, solid or twisted, copper
immediately turn OFF the power, and label it to clearly indicate its
function.
sensor that contains a diode.
voltage will be reached within 0.1 seconds. If the power supply
voltage is not reached quickly enough, the Counter may
malfunction or outputs may be unstable.
instantaneously. Outputs may malfunction and memory errors may
occur if the power supply voltage is decreased gradually.
uses a constant read-in system, output will turn ON if the set value
is equal to the present value.
the H7CZ uses a constant read-in system, the output status will
change if the comparison value is changed to a value on the other
side of the present value.
strong alkali, or strong acids. They will damage the external finish.
The indicator, LCD, and resin parts may deteriorate more quickly
depending on the application environment, preventing normal
indications. Periodic inspection and replacement are required.
depending on the application environment. Periodic inspection and
replacement are required.
0 V
Input
Sensor
Diode
H7CZ
17