MCBACIP CARLO GAVAZZI, MCBACIP Datasheet - Page 5

BACNET-IP PORT MODULE

MCBACIP

Manufacturer Part Number
MCBACIP
Description
BACNET-IP PORT MODULE
Manufacturer
CARLO GAVAZZI
Datasheet

Specifications of MCBACIP

Accessory Type
BACNet-IP Port Module
For Use With
WM3096 Type Smart Modular Power Analyzer
Output specifications (cont.)
WM30 96
Specifications are subject to change without notice
Insulation
RS485/RS422 port
(on request)
Insulation
RS232 port (on request)
Signal retransmission
Scaling factor
Response time
Ripple
Total temperature drift
Load
Type
Connections
Addresses
Protocol
Data (bidirectional)
Data format
Baud-rate
Driver input capability
Note
Type
Dynamic (reading only)
Static (reading and writing only) All the configuration
The signal output can be
connected to any
instantaneous variable
available in the table “List
of the variables that can be
connected to”.
Programmable within the
whole range of
retransmission; it allows
the retransmission
management of all values
from 0 to 10VDC.
≤400 ms typical (filter
excluded)
≤1% (according to IEC
60688-1, EN 60688-1)
≤500 ppm/°C
≥10kΩ
See “Insulation between
inputs and outputs” table
Multidrop, bidirectional
(static and dynamic
variables)
2-wire
Max. distance 1000m,
termination directly on the
module
247, selectable by means
of the front key-pad
MODBUS/JBUS (RTU)
System and phase
variables: see table “List of
variables...”
parameters.
1 start bit, 8 data bit,
no/even/odd parity,1 stop
bit
Selectable: 9.6k, 19.2k,
38.4k, 115.2k bit/s
1/5 unit load. Maximum
160 transceivers on the
same bus.
With the rotary switch (on
the back of the basic unit)
in lock position the
modification of the
programming parameters
and the reset command by
means of the serial
communication is not
allowed anymore. In this
case just the data reading
is allowed.
See “Insulation between
inputs and outputs” table
Bidirectional (static and
dynamic variables)
WM30 96 DS 271109
Note
Insulation
Ethernet/Internet port
(on request)
Insulation
BACnet-IP
(on request)
Connections
Protocol
Data (bidirectional)
Data format
Baud-rate
Protocols
IP configuration
Port
Client connections
Connections
Note
Protocols
Dynamic (reading only)
Static (reading and writing only) All the configuration
Data (bidirectional)
Dynamic (reading only)
Static (reading and
writing only)
3 wires. Max. distance
15m
MODBUS RTU /JBUS
System and phase
variables: see table “List of
variables...”
parameters
1 start bit, 8 data bit,
no/even/odd parity,1 stop
bit
Selectable: 9.6k, 19.2k,
38.4k, 115.2k bit/s
With the rotary switch (on
the back of the basic unit)
in lock position the
modification of the
programming parameters
and the reset command by
means of the serial
communication is not
allowed anymore. In this
case just the data reading
is allowed.
See “Insulation between
inputs and outputs” table
Modbus TCP/IP
Static IP / Netmask /
Default gateway
Selectable (default 502)
Max 5 simultaneously
RJ45 10/100 BaseTX
Max. distance 100m
System and phase
variables: see table “List of
variables...”
All the configuration
parameters.
With the rotary switch (on
the back of the basic unit)
in lock position the
modification of the
programming parameters
and the reset command by
means of the serial
communication is not
allowed anymore. In this
case just the data reading
is allowed.
See “Insulation between
inputs and outputs” table
BACnet-IP (for
measurement reading
purpose) and Modbus
TCP/IP (for measurement
5