XTAE007B10A2P4 EATON CUTLER HAMMER, XTAE007B10A2P4 Datasheet - Page 239

IEC Non-Reversing Starter

XTAE007B10A2P4

Manufacturer Part Number
XTAE007B10A2P4
Description
IEC Non-Reversing Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTAE007B10A2P4

No. Of Phases
Single Or Three
Power Rating
3.5kW
Current Rating
7A
Operating Temperature Range
-25°C To +50°C
Mounting Type
DIN Rail
Overload Adjustment Current Max
2.4A
Overload Adjustment Current Min
1.6A
Supply Voltage Max
120VAC
Frame Size
Standard
Table 310.16. Allowable Ampacities of Insulated Conductors Rated 0–2000V, 60°–90°C [140°–194°F],
Not More Than Three Current-Carrying Conductors in Raceway or Cable or Earth (Directly Buried),
Based on Ambient Temperature of 30°C [86°F]—Correction Factors
Size
AWG
kcmil
Ambient
Temp. °C
21–25
26–30
31–35
36–40
41–45
46–50
51–55
56–60
61–70
71–80
Where the number of current-carrying conductors in a raceway or
cable exceeds three, the allowable ampacities shall be reduced
as shown in the following table:
Table 310.15 (B)(2)(a). Adjustment Factor for More Than
Three Current-Carrying Conductors in Raceway or Cable
Number of Current-Carrying
Conductors
4–6
7–9
10–20
21–30
31–40
41 and above
Where single conductors or multiconductor cables are stacked
or bundled longer than 24 in (610 mm) without maintaining
spacing and are not installed in raceways, the allowable
ampacity of each conductor shall be reduced as shown in
the above table.
Temperature Rating of Conductor. See NEC Table 310-13.
Copper
60°C [140°F]
Types
TW†, UF
For Ambient Temperatures Other Than 30°C [86°F], Multiply the
Allowable Ampacities Shown in the Table on Page V5-T27-238
by the Appropriate Factor Shown Below
1.08
1.00
0.91
0.82
0.71
0.58
0.41
75°C [167°F]
Types
FEPW , RH , RHW ,
THHW , THW ,
THWN , XHHW ,
USE , ZW
1.05
1.00
0.94
0.88
0.82
0.75
0.67
0.58
0.33
Percent of Values in Tables as Adjusted
for Ambient Temperature if Necessary
80
70
50
45
40
35
90°C [194°F]
Types
TBS, SA, SIS, FEP , FEPB , MI,
RHH , RHW-2, THHN , THHW ,
THW-2 , THWN-2 , USE-2,
XHH, XHHW , XHHW-2, ZW-2
1.04
1.00
0.96
0.91
0.87
0.82
0.76
0.71
0.58
0.41
Volume 5—Motor Control and Protection CA08100006E—May 2011 www.eaton.com
IEC Contactors and Starters
Notes
Reprinted by permission from NFPA 70-2005. National Electrical Code
National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
Unless otherwise specifically permitted elsewhere in this
for conductor types marked with an obelisk (†) shall not exceed 15A for No. 14, 20A for No.
12 and 30A for No. 10 copper; or 15A for No. 12 and 25A for No. 10 aluminum and copper-
clad aluminum after any correction factors for ambient temperature and number of conductors
have been applied.
Aluminum or Copper-Clad Aluminum
60°C [140°F]
Types
TW , UF
For Ambient Temperatures Other Than 30°C [86°F], Multiply the
Allowable Ampacities Shown in the Table on Page V5-T27-238
by the Appropriate Factor Shown Below
1.08
1.00
0.91
0.82
0.71
0.58
0.41
75°C [167°F]
Types
RH , RHW ,
THHW , THW ,
THWN , XHHW ,
USE
1.05
1.00
0.94
0.88
0.82
0.75
0.67
0.58
0.33
XT IEC Power Control
90°C [194°F]
Types
TBS, SA, SIS, THHN ,
THHW , THW-2, THWN-2,
RHH , RHW-2, USE-2, XHH,
XHHW, XHHW-2, ZW-2
1.04
1.00
0.96
0.91
0.87
0.82
0.76
0.71
0.58
0.41
, the overcurrent protection
27.1
®
, Copyright
V5-T27-239
Size
AWG
kcmil
Ambient
Temp. °F
70–77
78–86
87–95
96–104
105–113
114–122
123–131
132–140
141–158
159–176
©
2005.