LE1D09V7 TELEMECANIQUE, LE1D09V7 Datasheet - Page 10

STARTER, ENCLOSED, 4KW

LE1D09V7

Manufacturer Part Number
LE1D09V7
Description
STARTER, ENCLOSED, 4KW
Manufacturer
TELEMECANIQUE
Datasheet

Specifications of LE1D09V7

Supply Voltage Range
220Vac To 460Vac
Power Rating
4kW
Current Rating
9A
Approval Bodies
IEC
Breaking Capacity Current Ac
250A
Coil Holding Power
7VA
Coil Voltage Vac Nom
400V
Contact Current Max
9A
Conforming to standards
Product certifications
Protective treatment
Degree of protection
Ambient air temperature
around the device
Recommendation
Rated insulation voltage
Rated operational voltage
Protection
Built-in protection
Indication
Electrical durability
Module type
Type of protection
Rated control circuit voltage (Uc)
Maximum peak voltage
Natural RC frequency
Mechanical latch block type
For mounting on contactor
Certification
Rated insulation voltage
Rated control circuit voltage
Power required
Maximum operating rate
On-load factor
Mechanical durability at Uc
Environment
“Auto - Man - Stop” control modules
Coil suppressor modules
Mechanical latch blocks
Characteristics
References:
pages 2/18 to 2/21
Schneider Electric
Dimensions:
pages 2/44 and 2/45
Unlatching can be manually operated locally or electrically controlled for remote operation.
The LA6-DK or LAD-6K latch coil and the LC1-D operating coil must not be energised simultaneously. The duration of
the LA6-DK or LAD-6K and LC1-D control signals must be
Conforming to IEC 68
Conforming to VDE 0106
Storage
Operation
Permissible for operation at Uc
The Auto - Man selector switch must only be operated with the Start - Stop (“O” “I”) switch in position “O”
Conforming to EN 60947-5-1
Conforming to EN 60947-5-1
Against electric shocks
Contactor coil suppression
By integral LED
In operating cycles
Conforming to IEC 947-5-1
" 50/60 Hz and $
For unlatching
In operating cycles/hour
In millions of operating cycles
TeSys contactors
Control modules, coil suppressor modules
and mechanical latch blocks
for model d contactors
Schemes:
pages 2/48 and 2/49
24/48 V
50/127 V
110/240 V
380/415 V
"
$
°C
°C
°C
V
V
kV
V
V
V
VA
W
Hz
Hz
Hz
Hz
IEC 947-5-1
UL, CSA
“TH”
Protection against direct finger contact IP 2X
- 40…+ 80
- 25…+ 55
- 25…+ 70
250
250
2
By varistor
Illuminates when the contactor coil is energised
20,000
LA4-DA
LAD-4RC
RC circuit
"
24…415
3 Uc
400
200
100
150
LA6-DK10
LC1D40…D65,
LP1-D65
UL, CSA
690
24…415
25
30
1200
10 %
0.5
100 ms.
LA4-DB
LAD-4T
Bidirectional
peak limiting
diode
" or $
24…72
2 Uc
LAD-6K10
LC1-D09…D38,
DT20…DT60
LA4-DC
Diode
$
12…250
Uc
LA6-DK20
LC1-D80…D150
LP1-D80
and LC1-D115
UL, CSA
690
24…415
25
30
1200
10 %
0.5
LA4-DE
LAD-4V
Varistor
" or $
24…250
2 Uc
2/41
2

Related parts for LE1D09V7