MMX34AA7D6F0-0 MOELLER, MMX34AA7D6F0-0 Datasheet - Page 4

no-image

MMX34AA7D6F0-0

Manufacturer Part Number
MMX34AA7D6F0-0
Description
INVTR FREQ 3PH 3KW
Manufacturer
MOELLER
Datasheet

Specifications of MMX34AA7D6F0-0

Supply Voltage Range
323VAC To 528VAC
No. Of Phases
Three
Power Rating
3kW
Output Voltage Max
10V
Frequency Range
45Hz To 66Hz
Svhc
No SVHC (18-Jun-2010)
Approval Bodies
CE, C-Tick, CUL, UL
Current Limit
RoHS Compliant
Frequency inverters - simple and straightforward
Display unit
Backlit liquid crystal display (LCD)
Status symbols (D):
READY
RUN
STOP
ALARM = Alarm message active
FAULT
Menu level (Y):
REF
MON
PAR
FLT
Control commands (C):
FWD
REV
I/O
KEYPAD = Via the keypad
BUS
Features
Integrated RFI filter (EMC: C2 and C3 to/EN61800-3)
Dynamic motor control with sensorless vector control or V/f
control (selectable)
Integrated keypad and display unit
Electronic reference value potentiometer
Fixed frequencies
PI controller
Integrated brake unit (with MMX34 in sizes 2 and 3)
6 digital control inputs (24 V DC)
1 digital output (transistor, 24 V DC, 50 mA)
2 analog inputs (0...+10 V DC and 0/4.20 mA)
1 output analog (0/4...20 mA)
Serial interface (RS485 / Modbus RTU)
2 relays (1x NO, 1x changeover, 230 V AC, 2 A)
International standards (CE, UL, cUL, c-Tick)
= Ready to start
= Operational
= Stop, Stop command active
= Drive was stopped due to an error message
= Reference value entry
= Monitor operating data
= Parameters
= Fault memory (Fault)
= Forward run
= Reverse run
= Via control terminals (Input/Output)
= Via fieldbus (interface)
Function keys
Application examples
Speed control of asynchronous three-phase motors up to
5.5 kW (400 V)
Pump and fan applications in buildings and industrial areas
with quadratic and linear load characteristics.
The high speed accuracy (sensorless) allows a whole range
of possible applications in the textile, paper and printing
industry, as well as with finishing machines in the metal
industry.
The compact design with integrated EMC filter offers
maximum flexibility in machine building and saves valuable
mounting space.
The twofold startup torque and 1.5 overload torque allows
the implementation of applications with demanding speed
and torque requirements.
START
Motor start via keypad
(function must be activated)
STOP
OK
BACK/RESET
Back in menu. Exit edit mode and acknowledge
error messages (reset).
LOC/REM
Move between different control levels (keypad –
control terminals – fieldbus)
UP/DOWN
Motor stop via keypad
Acknowledges the display fault message (Reset)
Activates the Startup Wizard (press for 5 s)
Activates the selected parameter
Confirm the set value
Parameter group selection (submenu)
Menu level selection in the display unit (
Change in the parameter groups and
parameter lists
Increase and reduce parameter values
Increase and reduce reference value
(electronic motor potentiometer)
Y)
4