VARIABLE SPEED DRIVE UNIT, 51SERIES

DF51-340-2K2

Manufacturer Part Number
DF51-340-2K2
Description
VARIABLE SPEED DRIVE UNIT, 51SERIES
Manufacturer
MOELLER
Datasheet

Specifications of DF51-340-2K2

Supply Voltage Range
342VAC To 528VAC
No. Of Phases
Three
Power Rating
2.2kW
Output Voltage Max
528VAC
Frequency Range
47Hz To 63Hz
Svhc
No SVHC (18-Jun-2010)
Approval Bodies
EN50178,
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Type: DF51−340−2K2
Article No.: 289125
Sales text """Frequency inverter DF51(2,2kW; 400V)"
Notes concerning the table header
All rating data of the power section is based on a switching frequency of 5 kHz (default setting) and
an ambient temperature of +40 °C, for operation of a four−pole three−phase asynchronous motor.
1
Ordering information
Rated voltage
Max. rated operational current
Rated power for motors
Rating range
Description
General
Standards
Ambient temperature
Operating temperature
Max. duty factor (c.d.f.) with lowest
impedance R
at 400 V 3−phase AC
B
U
I
P
e
e
°C
°C
kW
V
A
3 AC 342...528 V ± 0 %
5.5
2.2
0.37 – 7.5 kW at 400 V
Three−phase connection
EN 50178, IEC 61800−3
−10 to +40 with rated current I
at a clock frequency of 5 kHz;
up to +50 °C at a reduced
clock frequency of 2 kHz and
reduced output current of 80 %
I
–25...+70
e
e

Related parts for DF51-340-2K2

DF51-340-2K2 Summary of contents

Page 1

... Type: DF51−340−2K2 Article No.: 289125 Sales text """Frequency inverter DF51(2,2kW; 400V)" Ordering information Rated voltage Max. rated operational current Rated power for motors at 400 V 3−phase AC Rating range Description Notes concerning the table header All rating data of the power section is based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40 ° ...

Page 2

Shock resistance Pollution degree Climatic proofing Altitude Mounting position Free surrounding areas Emitted interference Interference immunity Insulation resistance Discharge current to PE Protection type Protection against direct contact Protective isolation against switching circuitry Protective measures Heat dissipation with rated operational ...

Page 3

Output voltage Output frequency Frequency resolution Frequency resolution Frequency error limit ± Max. rated operational current Permissible overcurrent Torque during start Standard operation at 150 % overload Assigned motor rating (4−pole ASM) 230 V Control ...

Page 4

... All rating data of the power section is based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40 °C, for operation of a four−pole three−phase asynchronous motor. Moeller GmbH, Hein−Moeller−Str. 7−11, D−53115 Bonn E−Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net Copyright 2006 by Moeller GmbH. HPL−C2007G V2 × + (configurable), resolution 10 bit ...

Related keywords