HS6E-M7Y4B03-G IDEC, HS6E-M7Y4B03-G Datasheet - Page 6

SWITCH, SAFETY INTERLOCK, 2NC, 2A

HS6E-M7Y4B03-G

Manufacturer Part Number
HS6E-M7Y4B03-G
Description
SWITCH, SAFETY INTERLOCK, 2NC, 2A
Manufacturer
IDEC
Series
HS6Er
Datasheet

Specifications of HS6E-M7Y4B03-G

Contact Voltage Ac Max
125V
Contact Voltage Dc Max
30V
Contact Current Ac Max
2A
Contact Current Dc Max
2A
Switch Terminals
Cable
Contact Configuration
SPST-NC / SPST-NC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Small interlock switch with five poles and solenoid.
Ideal for applications in tight spaces.
6
• Compact body: 75 × 15 × 75 mm
• Reversible mounting and angled cable allow four actuator insertion
• Energy saving. 24V DC, 110 mA (solenoid: 100 mA, LED: 10 mA)
• Manual unlocking possible on three sides.
• RoHS compliant
• LED indicator shows solenoid operation
Spring Lock Type
• Automatically locks the actuator without power applied to the solenoid.
• After the machine stops, unlocking is completed by the solenoid.
• Manual unlocking is possible on three sides in the event of power
Solenoid Lock Type
• The actuator is locked when energized.
• The actuator is unlocked when de-energized.
• Flexible locking function can be achieved, for an application where
Ratings
• • • • Contact Ratings
• Minimum applicable load (reference value): 3V AC/DC, 5 mA
• UL rating
• TÜV rating
• • • • Solenoid/Indicator
Rated Insulation Voltage (Ui) (Note 1)
Rated Thermal Current (Ith)
Rated Voltage (Ue)
Locking Mechanism
Rated Voltage
Rated Current
Main/Lock Monitor: 125V AC, 1A Pilot duty
Door Monitor:
Main & lock monitor circuit: AC-15 125V/1A, DC-13 125V/0.22A
Door monitor circuit: AC-15 240V/0.75A, DC-13 250V/0.27A
15-mm-wide, thinnest solenoid type interlock switch in the world.
directions.
failure or maintenance.
locking is not required and sudden stopping of a machine must be
prevented.
HS6E
Coil Resistance
Pickup Voltage
Dropout Voltage
Maximum Continuous
Applicable Voltage
Maximum Continuous
Applicable Time
Insulation Class
Light Source
Illumination Color
AC
DC
AC
DC
Resistive load (AC-12)
Inductive Load (AC-15)
Resistive load (DC-12)
Inductive Load (DC-13)
Resistive load (AC-12)
Inductive Load (AC-15)
Resistive load (DC-12)
Inductive Load (DC-13)
125V DC, 0.22A Pilot duty
240V AC, 0.75A Pilot duty
250V DC, 0.27A Pilot duty
24V DC
110 mA (solenoid 100 mA, LED 10 mA)
(initial value)
240Ω (at 20°C)
Rated voltage × 85% maximum (at 20°C)
Rated voltage × 10% minimum (at 20°C)
Rated voltage × 110%
Continuous
Class F
LED
Green
Spring Lock Type
Subminiature Interlock Switches with Solenoid
300V (door monitor contact)
150V (lock monitor contact)
30V (between LED or solenoid and
ground)
Operating temperature –25 to 35°C
Operating temperature 35 to 50°C
2.5A (up to 2 circuits)
1.0A (3 or more circuits)
1.0A (1 circuit)
0.5A (2 or more circuits)
2.5A
2.3A
30V
2A
1A
Solenoid Lock Type
0.22A
0.55A
125V
0.4A
2.5A
1.5A
1.1A
2A
1A
0.75A
0.55A
0.27A
250V
1.5A
Specifications
Applicable Standards
Operating
Temperature
Relative Humidity
Storage Temperature
Pollution Degree
Impulse Withstand
Voltage
Insulation Resistance
(500V DC megger)
Contact Resistance
Electric Shock
Protection
Degree of Protection
Shock Resistance
Vibration Resistance
Actuator Operating
Speed
Direct Opening Travel 8.0 mm minimum
Direct Opening Force 60N minimum
Actuator Retention
Force
Operating Frequency
Mechanical Durability 1,000,000 operations minimum (GS-ET-19)
Electrical Durability
Conditional
Short-circuit Current
Cable
Cable Diameter
Weight (approx.)
• Straight Actuator
(SUS304)
• Horizontal/Vertical Angle Adjustable Actuators
UL 508 (UL listed)
CSA C22.2, No. 14 (c-UL listed)
ISO 14119
IEC 60947-5-1
EN 60947-5-1 (TÜV approval)
EN 1088 (TÜV approval)
GS-ET-19
IEC 60204-1/EN 60204-1 (applicable standards for use)
–25 to +50°C (no freezing)
45 to 85% (no condensation)
–40 to +80°C (no freezing)
3
Main & lock monitor circuits: 1.5 KV
Door monitor circuit: 2.5 kV
Between solenoid/LED and ground: 0.5 kV
Between live and dead metal parts: 100 MΩ minimum
Between terminals of different poles: 100 MΩ minimum
300 mΩ maximum (initial value, 1m cable)
500 mΩ maximum (initial value, 3m cable)
700 mΩ maximum (initial value, 5m cable)
Class II (IEC 61140)
IP67 (IEC 60529)
Operating extremes: 100 m/s
Damage limits:
Operating extremes:
Damage limits: 30 Hz, amplitude 1.5 mm
0.05 to 1.0 m/s
500N minimum (GS-ET-19)
900 operations/h
100,000 operations minimum (rated load)
1,000,000 operations minimum (24V AC/DC, 100 mA)
(operating frequency 900 operations/h)
50A (250V)
(Use 250V/10A fast-blow fuse for short-circuit protection.)
UL2464, No. 22 AWG
(12-core: 0.3 mm
ø7.6 mm
200g (HS6E-∗∗∗01)
• Right-angle Actuator (SUS304)
10 to 55 Hz, amplitude 0.35 mm
2
or equivalent/core)
1000 m/s
2
(10G)
2
(100G)
(07/03/12)

Related parts for HS6E-M7Y4B03-G