ZE-Q22 2G Omron, ZE-Q22 2G Datasheet - Page 3

no-image

ZE-Q22 2G

Manufacturer Part Number
ZE-Q22 2G
Description
SWITCH, ROLLER PLUNGER
Manufacturer
Omron
Datasheet

Specifications of ZE-Q22 2G

Contact Voltage Ac Max
480V
Contact Voltage Dc Max
250V
Contact Current Ac Max
15A
Contact Current Dc Max
500mA
Switch Terminals
Screw
Svhc
No SVHC (15-Dec-2010)
Actuator Type
Roller Plunger
■ Ratings
Note: 1. The above figures are for standard currents.
■ Characteristics
Note: 1. The above figures are initial values.
ZE-@
ZV-@
ZV2-@
XE-@
XV-@
XV2-@
Inrush current
Degree of protection
Durability (see note 3)
Operating speed
Operating frequency
Rated frequency
Insulation resistance
Contact resistance
Terminal temperature rise
Dielectric strength
Vibration resistance
Shock resistance (see note 4)
Ambient temperature (see note 1)
Ambient humidity
Weight
Contact
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
2. IP65 for @E-N models and IP60 for @E-Q models.
3. The values are calculated at an operating temperature of 5 C to 35 C, and an operating humidity of 40% to 70%. Contact your OMRON
4. At the operation limit positions.
5. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm lever.
6. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and sealed roller plunger.
sales representative for more detailed information on other operating environments.
Contact
NC
NO
125 VAC
250 VAC
480 VAC
125 VDC
250 VDC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Rated voltage
IP65 (see note 2)
Mechanical:
Z@: 10,000,000 operations min.
X@: 1,000,000 operations min.
Electrical:
Z@: 500,000 operations min., for 15 A, 250 VAC resistive load
X@: 100,000 operations min., for 10 A, 125 VDC resistive load
Plunger type: 0.01 mm to 0.5 m/s
Lever type:
Mechanical: 120 operations/min
Electrical:
50/60 Hz
100 M min. (at 500 VDC)
15 m max. (initial value)
50 max.
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal part and ground, and between each
terminal and non-current-carrying metal part (1,500 VAC for Z@ models and X@ models)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (see note 4)
Destruction: 1,000 m/s
Malfunction: 100 m/s
Operating: –10 C to 80 C (with no icing)
Operating: General-purpose type: 85% max.
Approx. 260 to 280 g
30 A max.
15 A max.
15 A
15 A
10 A
0.5 A
0.25 A
15 A
15 A
15 A
10 A
3 A
Sealed type:
20 operations/min
Resistive load
NC
0.02 mm to 0.5 m/s
2
min. (see note 5), 50 m/s
Non-inductive load
2
min.
NO
3 A
2.5 A
1.5 A
0.5 A
0.25 A
3 A
3 A
3 A
3 A
1.5 A
95% max.
NC
Enclosed Switches
Lamp load
1.5 A
1.25 A
0.75 A
3 A
3 A
3 A
1.5 A
0.75 A
2
NO
min. (see note 6)
15 A
15 A
6 A
0.05 A
0.03 A
15 A
15 A
10 A
7.5 A
2 A
Inductive load
NC
ZE/ZV/XE/XV
15 A
10 A
10 A
6 A
1.5 A
Inductive load
NO
5 A
3 A
1.5 A
0.05 A
0.03 A
10 A
10 A
10 A
6 A
2 A
NC
Motor load
2.5 A
1.5 A
0.75 A
10 A
10 A
6 A
4 A
1 A
F-121
NO

Related parts for ZE-Q22 2G