E53-CK01 Omron, E53-CK01 Datasheet - Page 20

no-image

E53-CK01

Manufacturer Part Number
E53-CK01
Description
COMPUTER COMMUNICATION OUTPUT BOARD
Manufacturer
Omron
Type
Ramp / Soak Process Controllerr
Datasheets

Specifications of E53-CK01

Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Mounting Type
Panel
Supply Voltage Max
240VAC
Supply Voltage Min
100VAC
Control Method
ON/OFF and PID Control
Voltage Rating
240 V
Mounting
Horizontal Mount
Display Type
7-Segment
Features
Modular structure, one-stock type
Input Type
Analog
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E53CK01
J CT Input/Potentiometer (for E5AK and E5EK only)
E5AK CT Input/Potentiometer
When using the HBA function on the E5AK-AA2 Controller,
connect Current Transformer input (CT) to terminal numbers 15
to 17. When monitoring the valve opening on the E5AK-PRR2
Controller, connect the potentiometer (PTMR) to terminal
numbers 15 to 17. Connect each of these inputs as follows:
For details on CT inputs, refer to Appendix, About Current
Transformer in your User’s Manual. For details on the
potentiometer, refer to the Instruction Manual for the valve
connected to the Controller. The variable resistance range is
100 Ω to 2.5 kΩ.
J Remote Set Point Input (for E5AK and E5EK only)
E5AK Remote SP Input
Connect the input (RSP) to be used as the remote SP to terminal
numbers 21 and 22. Only 4 to 20 mA inputs can be connected.
Connect the input as follows:
10
20
9
8
7
6
5
4
3
2
1
10
9
8
7
6
5
4
3
2
1
Digital Process Controller
30
29
28
27
26
25
24
23
22
21
30
29
28
27
26
25
24
23
22
21
31 32
33
31 32
33
20
19
18
17
16
15
14
13
12
11
20
19
18
17
16
15
14
13
12
11
17
16
15
CT input
17
16
15
22
21
Potentiometer
W
E5 K
O
C
+
--
4 to 20 mA
CT
E5EK CT Input/Potentiometer
When using the HBA function on the E5EK-AA2 Controller,
connect Current Transformer input (CT) to terminal numbers 15
to 17. When monitoring the valve opening on the E5EK-PRR2
Controller, connect the potentiometer (PTMR) to terminal
numbers 15 to 17. Connect each of these inputs as follows:
For details on CT inputs, refer to Appendix, About Current
Transformer in your User’s Manual. The potentiometer cannot be
used simultaneously with remote SP input. For details on the
potentiometer, refer to the Instruction Manual for the valve
connected to the Controller. The variable resistance range is 100
Ω to 2.5 kΩ.
E5EK Remote SP Input
Connect the input (RSP) to be used as the remote SP to terminal
numbers 15 and 16. However, note that the potentiometer cannot
be used simultaneously with remote SP input. Only 4 to 20 mA
inputs can be connected. Connect the input as follows:
10
10
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
21 22
23
21 22
23
20
19
18
17
16
15
14
13
12
11
20
19
18
17
16
15
14
13
12
11
16
15
17
16
15
CT input
17
16
15
Potentiometer
W
O
C
+
--
4 to 20 mA
CT

Related parts for E53-CK01