TC4810-02 TEMPATRON, TC4810-02 Datasheet - Page 3

TEMPERATURE CONTROLLER, K, T/C

TC4810-02

Manufacturer Part Number
TC4810-02
Description
TEMPERATURE CONTROLLER, K, T/C
Manufacturer
TEMPATRON
Datasheet

Specifications of TC4810-02

Thermocouple Type
K
Operating Temperature Max
50°C
Operating Temperature Min
-10°C
Output Voltage Max
240VAC
Accuracy
± 2%
Approval Bodies
CE, EN50081-1, EN50082-1, EN61010-1
CONNECTION DIAGRAM
CONNECTION DIAGRAM
DIMENSIONS
Supply voltage:
Power drain:
Operating
resistance range:
Sensing delay:
Output rating:
Electrical life:
Ambient range:
Approvals:
Weight:
SPECIFICATION
Supply voltage:
Power drain:
Operating res:
Sensing delay:
Output rating:
Electrical life:
Ambient range:
Approvals:
Weight:
STANDARD ITEM
Note: For suitable panel mounting or DIN rail sockets see page 33.
SPECIFICATION
Type
Differential Level sensor
FLDT LIQUID LEVEL DETECTOR
Differential or single point sensing
Dual supply voltage
OP
LEVEL
CONTROLLER
IN1 IN2
~
110/230(220-240)Vac @ 50/60 Hz
4VA
2K ON, 5K OFF to 20K ON, 59K OFF
500 msec typical
SPCO relay rated at 5A/240Vac/30Vdc resistive
100,000 ops at rated load
-10 to 60 C non-condensing
Conforms to CE emc EN50081-1 & EN50082-1
and low voltage EN61010-1 directives
200gms
110/230(220-240)Vac @ 50/60 Hz
4VA
950
500 msec typical
SPCO relay rated at 5A/240Vac/30Vdc resistive
100,000 ops at rated load
-10 to 60 C non-condensing
Conforms to CE emc EN50081-1 & EN50082-1
and low voltage EN61010-1 directives
180gms
K on, 220K
Common
Common
o
o
4
3
4
3
5
5
4
The FLDT liquid level detector is design-
ed to operate with a differential sensing
device but by shorting the high and low
probes it can also be used for single
point detection. A sensitivity control on
the front of the unit enables it to be used
for a wide range of conductive liquids.
Under differential operation, the output
relay will energise when the liquid falls
below the 'Low' level and de-energise
when it rises above the 'High' level.
2
2
High
Low
6
6
1
1
High
Low
Panel Cut-out 45 x 45 mm
7
7
ff
11
11
Adjustable sensitivity control
8
8
10
10
ANALOGUE PROCESS CONTROLS
FLST-110/230VAC
99
Part Number
110Vac
230Vac
N
110Vac
230Vac
N
-0
+0.5
13
15
DIMENSIONS
Note: For suitable panel mounting or DIN rail sockets see page 33.
DIMENSIONS
STANDARD ITEM
SPECIFICATION
Supply voltage:
Power drain:
Scale accuracy:
Scale ranges:
Max ext. resist:
Control band:
Reset adjust:
Output rating:
Electrical life:
Ambient range:
CONNECTION DIAGRAM
STANDARD ITEMS
Type
Differential Level sensor
T3S ON/OFF & PROPORTIONAL TEMPERATURE CONTROLLER
Input
J T/c
J T/c
K T/c
K T/c
For suitable panel mounting or DIN rail wiring sockets see page 33.
Thermocouple
input
8
10
6
4
12
2
1
14
8 4 6
16 18
+
-
30
20
28
22
24
26
Output
Relay
Relay
Relay
Relay
PT100
input
90 to 264Vac/dc @ 50/60 Hz
5VA max.
+/- 1% of FSD
PT100: 99.9, 199, 399 C
J T/c: 199, 399 C
K T/c: 399, 799 C
T/couple: 100 , PT100: 5
On/Off: Hysteresis = 0.2 to 0.5% of scale range
Propl: Propl. band = up to 3% of scale range
+/-3% of scale range
Relay: 2A/240Vac resistive
SSR:
100,000 ops at rated load
-10 to 50 C non condensing
20mA/12Vdc
o
12
The T3S range of temperature controllers
offer easy to set, non programmable
digital on/off or proportional control.
Options are available for J/K
thermocouples and PT100 RTDs inputs
with either relay or SSR drive outputs.
2
0 to 199 C
0 to 399 C
0 to 399 C
0 to 799 C
3
Range
19
Selectable on/off or proportional action
Upto 800 C scale ranges
J, K T/couple or PT100 input options
Relay or SSR drive output options
1
-
Panel cut-out 45 x 45
o
o
4
Panel Cut-out 45 x 45 mm
o
o
o
o
8
+
o
o
5
7
SSR drive option
FLDT-110/230VAC
6
Part Number
73
74
per wire
Part Number
T3S-B4RJ2C
T3S-B4RJ4C
T3S-B4RK4C
T3S-B4RK8C
-0
+0.5
N
L
-0
+0.5
15
13

Related parts for TC4810-02