Specifications of E5AN-HPRR2BM-500
Related parts for E5AN-HPRR2BM-500
E5AN-HPRR2BM-500 Summary of contents
Page 1
... Refer to Safety Precautions on page 22. • Auto/manual switching • Temperature Controller Auxiliary Outputs status display • Two • Simple program • Three function • Logic operations • Control output ON/OFF count alarm • PV change rate alarm • Models optional with RS-485 or RS-232C communications E5AN-H/E5EN-H 1 ...
Page 2
... This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157) E5CN-H/E5AN-H/E5EN-H Digital Controllers Communications Manual Advanced Type (Cat. No. H159) 2 Advanced Digital Temperature Controller ...
Page 3
... E5AN-HSS2HHBFM-500 output input 4 to 20- 20-mA E5AN-HAA3BFM-500 output input 4 to 20- 20-mA E5AN-HSS3BFM-500 output input 4 to 20-mA E5AN-HPRR2BM-500 input 4 to 20- 20-mA E5AN-HPRR2BFM-500 output input 4 to 20-mA E5AN-HAA2HBMD-500 input 4 to 20-mA E5AN-HSS2HBMD-500 input 4 to 20- 20-mA E5AN-HAA2HHBFMD-500 output input 4 to 20-mA ...
Page 4
... E5EN-HAA2HHBFMD-500 output input 4 to 20- 20-mA 2 E5EN-HSS2HHBFMD-500 output input 4 to 20- 20-mA 2 E5EN-HAA3BFMD-500 output input 4 to 20- 20-mA 2 E5EN-HSS3BFMD-500 output input 4 to 20-mA 2 E5EN-HPRR2BMD-500 input 4 to 20- 20-mA 2 E5EN-HPRR2BFMD-500 output input Model E5AN-H Y92S-P4 E5EN-H Y92S-P5 Model 5.8 dia. E54-CT1 12.0 dia. E54-CT3 Model EST2-2C-MV4 ...
Page 5
... Set digitally using keys on the front panel or by using the RSP input. 11-segment digital display and individual indicators (7-segments display emulation also possible) Character height: E5AN-H: PV: 15.8 mm, SV: 9.5 mm, MV: 6.8 mm; E5EN-H: PV: 11.8 mm, SV: 8.1 mm, MV: 5.8 mm Indication method Content of 3-level display: PV/SV/MV, PV/SV/Bank No., or soak time remain ...
Page 6
... JPt100: JIS C 1604-1989, JIS C 1606-1989 Pt100: JIS C 1604-1997, IEC 751 PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard) E5AN-H/E5EN-H Analog input 2300.0 1800.0 1700.01700.0 1300.0 1300.0 Usable in the following ranges by scaling: − ...
Page 7
... Case 2 Case 3 (Always ON > < ⏐H⏐ > ⏐L⏐ E5AN-H/E5EN-H H < < < > 0 ⏐H⏐ ≥ ⏐L⏐ H > < 0 ⏐H⏐ ≤ ⏐L⏐ H < < < > 0 ⏐H⏐ ≥ ⏐L⏐ H > < 0 ⏐H⏐ ≤ ⏐L⏐ 7 ...
Page 8
... Provided on the bottom of the E5AN-H and E5EN-H. An E58-CIFQ1 USB-Serial Conversion Cable is required to connect the computer to the E5AN-H and E5EN-H. Setup Tool port Provided on the front of the E5AN-H and E5EN-H. An E58-CIFIR USB-infrared Conversion Cable is required to connect the computer to the E5AN-H or E5EN-H. ✽4 Approved UL 61010-1, CSA C22 ...
Page 9
... Models with detection for single-phase or three-phase heaters: Two inputs ±5% FS ±1 digit max. 0.1 to 49.9 A (in units of 0.1 A) Minimum detection ON time: 100 ms 0.1 to 49.9 A (in units of 0.1 A) Minimum detection OFF time: 100 ms 0.1 to 49.9 A (in units of 0.1 A) Minimum detection ON time: 100 ms E5AN-H/E5EN-H 9 ...
Page 10
... Note: 1. The load current must be within the derating curve. 2. There is no zero-cross function. Derating Curve for SSR Outputs (Reference Values) 1.5 1.25 1 0.75 0.5 6 0.25 0 −10 Condition A: SSR outputs 100% ON Condition B: SSR outputs 50% ON with 2-s control cycle E5AN-H/E5EN-H Condition B Condition Ambient temperature (°C) ...
Page 11
... E53-EN03 E53-AKB RS-422 RS-485 11 RDB 11 B (+) 11 12 RDA (− NOT USE B (+) 21 SDB SDA 22 A (− Auxiliary output 3 15 Auxiliary output 3 Relay output SPDT, 250 VAC (resistive load) DON’T USE V mA DON’T USE t/c Pt E5AN-H/E5EN-H Event Inputs EV2 EV1 11 ...
Page 12
... E53-C3N or E53-C3DN Output Unit is used. For these combinations, maintain the following mounting space between Controllers. Terminal Cover Mounting Bracket (E53-COV16) (Accessory) (Accessory) Crimp terminal size: M3.5 120 min. E5AN-H/E5EN-H E5EN-H Operation indicators SUB1 SUB2 HA SUB3 PV Temperature unit SV ...
Page 13
... Group mounting is not possible in the vertical direction. (Maintain the specified mounting space between +0.8 92 Controllers.) 0 • When two or more Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. 60 min E5AN-H/E5EN-H 13 ...
Page 14
... Advanced Digital Temperature Controller (2,000) With Mounting Adapter Connected 16 18.5 Mounting Adapter (Accessory) 99.2 23.1 21.8 (75) LED indicator: SD 250 USB connector (type A plug) 1.2 3.2 10 44.8 E5AN-H/E5EN-H 54 4.6 dia. LED indicator (2,100) 1,765 LED indicator: RD 35.8 LED indicator: SD 17.8 Serial connector ...
Page 15
... Maximum continuous heater current: 120 A (50/60 Hz) (Maximum continuous heater current for an OMRON Temperature Controller is 50 A.) Number of windings: 400±2 Winding resistance: 8±0.8 Ω 100 ∞ kΩ 500 Ω 100 mV 100 Ω 50 Ω Ω 100 μ 100 100 1,000 A Thru-current (Io) A (r.m.s.) E5AN-H/E5EN-H Distor- tion factor 10 ...
Page 16
... Advanced Digital Temperature Controller E5AN-H/E5EN-H ...
Page 17
... Under these conditions, control output and alarm output will operate normally. For details on the control range, refer to the E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157). ✽ These errors are displayed only when the PV/SP is displayed. Errors are not displayed for other displays. ...
Page 18
... E5EN-H / E5AN-H Some parameters are not displayed depending on the model of the Controller and parameter settings. For details, refer to the E5CN-H/E5AN-H/ E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157). Protect Level PID Setting Level Display PID Selection d. pid PID1 1 d. pid ...
Page 19
... Root 0.0 Low-cut Point M ✽1. When the PF Setting parameter is set to A-M for a Controller with a PF Key (E5AN-H/E5EN-H). ✽2. When the PF Setting parameter is set to PFDP for a Controller with a PF Key (E5AN-H/E5EN-H). Advanced Digital Temperature Controller Power ON Starting in manual mode. Manual Control Level ...
Page 20
... Setting Change Protect: wtpt Protects changes to setups off by operating the front panel keys. M pfpt PF Key Protect Restricts PF key operation off (E5AN-H/E5EN-H only) M Parameter Mask Enable: pmsk Displayed only when a on parameter mask is set. M prlp Password to Move to Protect Level: 0 ...
Page 21
... M M ocu Heater Overcurrent sub2 Auxiliary Output 2 Assignment Use on alm2 M M ocl Heater Overcurrent sub3 Auxiliary Output 3 Assignment Latch off alm3 (E5AN/E5EN-H only och Heater Overcurrent csel Character Select Hysteresis 0 Setting t-u Soak Time Unit a Advanced Digital Temperature Controller Monitor/Setting ...
Page 22
Safety Precautions !CAUTION Do not touch the terminals while power is being supplied. Doing so may occasionally result in minor injury due to electric shock. Do not allow pieces of metal, wire clippings, or fine metallic shavings or filings from ...
Page 23
... Do not use an extension cable to extend the Conversion Cable length when connecting to the computer. Doing so may damage the Conversion Cable. 6. The E5AN-H/E5EN-H use the same port for communications through the infrared port and the Support Software port. Do not attempt to use communications through the Support Software port when the infrared port is being used ...
Page 24
... The Temperature Controller can be removed from the case to perform maintenance without removing the terminal leads. This is possible for only the E5CN, E5AN, and E5EN, and not for the E5CN-U. Check the specifications of the case and Temperature Controller before removing the Temperature Controller from the case. ...
Page 25
Advanced Digital Temperature Controller E5@N/E5@N-H 25 ...
Page 26
... OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE ...