4801K DIGITRON, 4801K Datasheet

TEMPERATURE CONTROLLER, K, T/C

4801K

Manufacturer Part Number
4801K
Description
TEMPERATURE CONTROLLER, K, T/C
Manufacturer
DIGITRON
Datasheet

Specifications of 4801K

Thermocouple Type
K
Operating Temperature Max
700°C
Operating Temperature Min
-50°C
Output Voltage Max
250VAC
Output Voltage Min
30V
Accuracy
± 0.5%
Ambient Conditions
0 Deg C To +45 Deg C
SAFETY STATEMENT
The design of this instrument has been checked to EN61010 for Class 11
use.
This operating instruction contains information and warnings that must be
observed to keep the instrument in a safe condition. The instrument
should not be switched on if it is damaged and it should not be used
under wet conditions.
For the correct and safe use of this instrument it is essential that both
operating and service personnel follow generally accepted safety
procedures in addition to the safety precautions specified.
Whenever it is likely that a safety protection has been impaired the
instrument must be made inoperative and be secured against any
unintended operation. Qualified maintenance or repair personnel should
be informed.
Safety protection is likely to be impaired, if for example, the instrument
shows visible damage or fails to operate normally.
To clean the instrument, disconnect all power sources and then wipe the
surface lightly with a clean, soft cloth dampened with water.
The instrument should preferably be operated in a clean, dry environment
with an ambient temperature of between 0°C and +50°C.
Before removing the covers for installation, maintenance, or repair,
the mains supply must be isolated.
This instrument is specified for use in a Pollution Category 11
Environment which is normally non-conductive with temporary light
condensation. This instrument must not be used in more hostile,
dusty or wet conditions.
Do not use this instrument in a flammable or explosive
atmosphere.
INSTRUCTIONS
OPERATING
SERIES
WARNING
4000
WARRANTY
This instrument has been carefully assembled and tested, and is
warranted against faulty workmanship and materials for 12 months from
the date of purchase.
During the warranty period any defective instrument will be repaired or
replaced at the discretion of the manufacturer This warranty does not
cover damage or failure resulting from misuse or accident.
Modification, adjustment or any alteration with the internal arrangement of
the instrument shall absolve the manufacturer from any liability in respect
of the instrument.
Any instrument to be repaired should be forwarded to the manufacturer,
carriage paid and at the owner’s risk.
A brief description of the fault should be included.
SYMBOLS AND TERMS
POWER AND FREQUENCY REQUIREMENTS
This instrument operates from line voltages to Installation Category 11,
local level supplies distributed within the building.
WARNING
Supply Voltage:
Power Consumption:
Fuse Rating:
Email: digitronsales@digitron.co.uk Website: www.digitron.co.uk
Telephone: +44 (0)1803 407693 Fax: +44 (0)1803 407699
!
Woodland Road, Torquay, Devon TQ2 7AY England
A division of Sifam Instruments Limited
Where caution is required. Refers the user to the
operator manual for further information.
This symbol warns the user that high voltages are
present close to this symbol.
These statements identify conditions or practices that
could be dangerous or fatal to personnel.
Alternating current.
Equipment protected throughout by reinforced
insulation.
216-253V a.c. 50/60Hz
109-126V a.c. 50/60Hz
230V a.c. 25mA
115V a.c. 45mA
230V a.c. 50mA (T) UL/CSA
115V a.c. 50mA (T) UL/CSA
XG.0430 rev.3
Figure 1
SELECTING AND INSTALLING POWER SUPPLY
(MODELS 4501, 4504, 4801, 4804)
Remove the PCB from its housing, locate the supply voltage selector as
shown in Figure 1, then configure to the desired voltage.
The supply should be wired to the terminal connector and fitted to the
appropriate position as indicated on the back of unit.
The cable should be clamped into position using the clamping arms
provided. It is imperative that all covers are replaced before the power
supply is switched on.
This instrument has different mains wiring details to instruments in
the same series manufactured before January 1 1997. We
strongly recommend close attention to the instruction manual
supplied with this instrument.
The instrument is not fitted with a separate a.c. power supply
on/off switch and will have a.c. voltages present whenever it is
connected.
1 2 3 4
Hysteresis
Control
WARNING
NC.COM.NO
Alarm Contact
where fitted
L
N
L
N
115v
or
230v

Related parts for 4801K

4801K Summary of contents

Page 1

... A brief description of the fault should be included. A division of Sifam Instruments Limited Woodland Road, Torquay, Devon TQ2 7AY England Telephone: +44 (0)1803 407693 Fax: +44 (0)1803 407699 Email: digitronsales@digitron.co.uk Website: www.digitron.co.uk XG.0430 rev.3 SYMBOLS AND TERMS Where caution is required. Refers the user to the ! operator manual for further information ...

Page 2

HYSTERESIS (MODELS 4801, 4804) The hysteresis is factory preset to ±2 counts. It should only be adjusted by qualified and trained staff, and using a small insulated screwdriver as indicated in Figure 1. It should not be carried out while ...