4600 C00100000010 CAL CONTROLS, 4600 C00100000010 Datasheet - Page 4

TEMP CONTROL, 1XRELAY 100-240V

4600 C00100000010

Manufacturer Part Number
4600 C00100000010
Description
TEMP CONTROL, 1XRELAY 100-240V
Manufacturer
CAL CONTROLS
Datasheet

Specifications of 4600 C00100000010

Thermocouple Type
J, K, R, S, T, B, C, D, E, L, N, PtRh
Output Voltage Max
240VAC
Output Voltage Min
120VAC
Accuracy
± 0.1%
Approval Bodies
CE, CUL, EMI - EN61326, UL
Approval Category
Fascia IP66
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
West Instruments/CAL Controls
The Hyde Business Park
Brighton BN2 4JU UK
Tel:
Fax:
e-mail:
Specification
Features
Control types
Auto manual
Output configuration
Alarms
Display
PC configuration
Input
Thermocouple
RTD
DC Linear
Accuracy
Sampling rate
Sensor break
Digital inputs
Outputs
Relay
SSR Driver
Triac
Linear DC
Transmitter PSU
Communications
Profiler
Memory
Segment types
Control
Datalogger
Data record options
Record modes
Recording Interval
Control
Environmental
Standards
Protection
Dimensions & Weight
For a detailed product specification please download the 4600 datasheet at www.cal-controls.com or call your nearest sales office
Ordering Information
+44 (0) 1273 606271
+44 (0) 1273 609990
Unit Type
Controller
Controller with USB Port
Controller/Recorder with USB Port
Profiler Option
Not Fitted
Profiler
Supply Voltage
100-240V AC
24-48V AC or DC
Option Slot 1
Not Fitted
Relay Output
DC Drive Output for SSR
Linear DC Output
Triac Output
Option Slot 2
Not Fitted
Relay Output
DC Drive Output for SSR
Linear DC Output
Triac Output
Dual Relay Output
Dual SSR Driver Output
24V DC Transmitter Power Supply
info@cal-controls.co.uk
4600
Full PID with pre-tune, auto-pretune, self-tune or manual tuning, heat only or heat & cool
Selectable with ‘bumpless’ transfer when switching between auto and manual control
Up to 9 for control, alarms, profiler event outputs, 24VDC transmitter PSU & retransmission.
Up to 5 alarms selectable as process high, process low, deviation & band, plus sensor break and loop alarms. Logical OR alarm outputs.
160 x 80 pixel, monochrome graphic LCD with a dual colour (red/green) backlight
BlueControl configuration and commissioning software
J, K, R, S, T, B, C, D, E, L, N, PtRh 20%:40%
3 wire PT100, NI120
0 -20mA, 4-20mA, 0-50mV, 10-50mV, 0-5V, 1-5V, 0-10V, 2-10V (0-100mV and 2Kohm pot also on aux-B input) scaling -1999 to 9999
±0.1% of input range ± 1 LSD, Thermocouple CJC, (Aux Input : ±0.25% of input range ± 1 LSD)
Process input 10 per second, Aux input : 4 per second
Detected within 2 secs, control goes to user preset power value.
Functions: setpoint select, control output, enable/disable, auto/manual control, profiler run/hold/abort, datalogger start/stop
Volt free contact or DC voltage: open contact / 2 to 24VDC signal = Logic high, closed contact / -0.6 to 0.8VDC signal = Logic low
Single relay: 2A resistive SPDT at 120/240VAC, >500,000 operations
Dual & Quad relay: 2A resistive SPST at 120/240VDC, >200,000 operations (dual) or >500,000 operations (quad)
Voltage >10V into 500Ω min
Operating voltage: 20 to 280Vrms (47 to 63Hz), Rating 0.01 to 1A @ 25°C
Ranges: 0-5V, 0-10V, 1-5V, 2-10V, 0-20mA & 4-20mA (selectable) ±0.25% of range (mA@250Ω, V@2kΩ)
Power rating 24V nominal (19 to 28VDC) into 910Ω min (option to use DC linear output as 0-10V adjustable Tx PSU)
RS232 via RJ11 cable, (configuraion only) RS485 - Modbus RTU master or slave, Ethernet - Modbus TCP slave (10 base-T or 100 base-T), Ver 1.1/2.0 USB host for memory stick
255 segments can be freely allocated in up to 64 programs
Ramp (rate or time), dwell (soak), hold (manual guaranteed soak or real-time profiling), loop (to previous segment), join another profile, end or repeat sequence
Run, hold, abort, profile select, jump to next segment, delayed profile start, real-time clock profile start.
PV (Process variable), max and min PV between samples, actual SP (setpoint), output power, alarm & event status, power on/off
FIFO (circular buffer) or run-then-stop (fixed buffer)
1, 2, 5, 10, 15, 30 sec or 1, 2, 5, 10, 15, 30 min
Manual; serial comms; digital input; synchronised with profile; PV rate of change; log on alarm
CE, UL, cUL. EMI - EN61326, Safety EN61010-1 & UL61010C-1 Polution degree 2, Installation category II
Fascia IP66 (IP65 with USB fitted), Behind panel IP20
Front Panel 96 x 96mm (Panel cutout 92 x 92mm), Behind panel depth -117mm. 0.65kg maximum
C
U
R
0
P
0
2
0
1
2
L
8
0
1
2
L
8
9
S
T
X
www.cal-controls.com
West Instruments is a division of Danaher UK Industries Ltd.
A member of the Danaher Corporation.
X
X
X
X
X
X
X
X
Available From:
X
X
0
R
0
1
2
L
8
9
S
1
2
3
4
5
0
0
1
3
4
5
0
1
1
T
24VDC Transmitter Power Supply
Remote Setpoint (RSP) Input A
Reserved for future options
DC Drive Output for SSR
Dual SSR Driver Output
RS485 Serial Comms
Display Language
Dual relay Output
Linear DC Output
Option Slot B
Option Slot A
Option Slot C
Option Slot 4
4 Relay Output
Option Slot 3
Digital Input 1
Relay Output
Ethernet Port
Triac Output
Aux input B
Not Fitted
Not Fitted
Not Fitted
Not Fitted
Not fitted
German
Spanish
English
French
Italian