CPM1A-20CDR-A-V1 Omron, CPM1A-20CDR-A-V1 Datasheet - Page 5

Micro Programmable Logic Controller

CPM1A-20CDR-A-V1

Manufacturer Part Number
CPM1A-20CDR-A-V1
Description
Micro Programmable Logic Controller
Manufacturer
Omron
Datasheets

Specifications of CPM1A-20CDR-A-V1

Output Type
Relay
External Width
86mm
Supply Voltage Max
240VAC
External Depth
70mm
Mounting Type
DIN Rail
External Height
90mm
Supply Voltage Min
100VAC
Approval Bodies
UL, CSA, CE
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Interval Timer Interrupts
The CPM1A has one interval timer. The interval timer shuts down the regular program irrelevant of the point in the cycle once the time is up,
and immediately executes an interrupt processing program. Interval timers are used in the following two modes.
Normal program
Analog Setting
The CPM1A contains two analog setting controls that can be used for a broad range of analog timer and counter settings. Turning the setting control
stores values of 0 to 200 (BCD data) in the SR area.
*Phillips screwdriver is required.
Program Example
44
Operation
Setting time
Analog setting 0
Analog setting 1
1. Analog timer for 0.0 to 20.0 seconds
A
Item
Analog setting 0
Analog setting 1
Analog setting
MOV(21)
ADD(30)
END(01)
An interrupt is executed only once when the time is up.
0.5 ms to 319,968 ms (0.1-ms units)
TIM
000
250
Value of the analog
setting 0 (0 to 200)
Interrupt processing program
One-shot mode
SR 250
SR 251
Interval timer
MOV(21)
SBN(92) 00
RET(93)
Storage area
2. Analog timer for 0.0 to 60.0 seconds
25313(ON)
B
Application Example:
Tact Operation Control of Conveyor Lines
A conveyor can be stopped temporarily as required for assembly
processes. When the timer function and limit switches are used in a
combination, conveyors can be stopped for a fixed time or can be run
at a constant speed for a fixed distance. Fine adjustment of the
stopping time can be easily done by using the analog setting controls.
*Phillips screwdriver is required.
Interrupts are executed repeatedly at fixed periods.
Analog setting 0
Analog setting 1
MUL(32)
250
#0003
DM0500
Application example
C
The number of pulse inputs is computed in the
interrupt mode at a fixed time to calculate the
speed.
omputing the Sheet Speed
TIM
001
0000 to 0200
DM 0500
BCD multiplication
Scheduled interrupt mode
Value of the analog setting 0
(0 to 200)
Triples the above value
Multiplication result (0 to 600)
Encoder
Setting value (BCD)
Programmable Controllers
CPM1A-V1