ATE
C702A
The Landing Contacts ensure a rugged construction
that will not scratch the card surface simultaneously
offering high durability.
Electrical
Contact resistance
Switch resistance
Insulation
High Voltage resistance
Unlock Solenoid PUSHMATIC Only
Rated Voltage/Current Use
Current pulse length
Pulse break
Environmental
Temperature
Vibration
Shock
PUSHMATIC with Shutter
Degree of Protection
Switch
Normally open.
Switch activates after data contacts mate.
Chatter time
Durability
Push Only
Push-Push
Push-Pull
PUSHMATIC
S
C5
C6
C7
C8
ISO
S
C5
C6
C7
C8
S
C1
C2
C3
C4
ISO
62,3
62,3
Landing Contact Full Smart Card Connectors
4,4
4,4
S
C1
C2
C3
C4
COUNTERSINK
110
COUNTERSINK
132
- < 100 mΩ
- < 200 mΩ
- 500VAC 1 min
- IEC 60512-4, Test 6d
- IEC 60512-4, Test 6c
- IP 30 (no card)
- 5 x 10
- 5 x 10
- 5 x 10
- 3 x 10
110
- > 10
- 5V/2.5A ± 10%
- 12V/1.1A ± 10%
- 24V/0.55A ± 10%
- 10… 25ms
- > 0.5s
- -25ºC thru 85ºC
- IP 20 (card inserted)
- < 5 ms
Fig 1
Fig 3
132
72,5
9
Ω
5
5
5
5
Cycles
Cycles
Cycles
Cycles
50
50
0,1
0,1
18,1
4,5
1
72,5
4,8
Card Readers
INACTIVE POSITION
Amphenol
INACTIVE POSITION
ACTIVE POSITION
Part Number:
C702 10M008 018 2
C702 10M008 015 2
C702 10M008 514 2
C702 10M008 522 2
C702 10M008 521 2
C702 10M008 523 2
C702 10M008 701 2
C702 10M008 700 2
C702 10M008 702 2
C702 10M008 703 2
C702 10M008 704 2
C702 10M008 705 2
C702 10M008 706 2
C702 10M008 707 2
C702 10M008 708 2
C702 10M008 732 2
C702 10M008 716 2
C702 10M008 727 2
C702 20M008 701 2
C702 20M008 700 2
C702 20M008 702 2
Push Only – Manual insertion, held in position by hand. Ideal for short cycle transactions.
Push-Push – Manual insertion, card held by reader, second push releases card.
Push-Pull – Manual insertion, card held by reader, card manually extracted.
PUSHMATIC – Manual insertion, card automatically ejected on completion of transaction.
*PUSHMATIC with Locking Detector – Senses complete insertion of card. Card is still visible but
not accessible. Automatic card release on completion of transaction.
**PUSHMATIC with Shutter (additional Bezel is NOT required) – The Shutter protects the card slot
when no card is present. The Shutter will only open upon insertion of a standard sized card.
(S) – Cable in Series
RELEASE
4,5
S
C4
C3
C2
C1
ISO + AFNOR
C5
C6
C7
C8
ISO + AFNOR
S
C4
C3
C2
C1
S
S
C4
C3
C2
C1
AFNOR
ISO
(P) – Cable in Parallel
S
C1
C2
C3
C4
S
C8
C7
C6
C5
S
C8
C7
C6
C5
S
C8
C7
C6
C5
SOLENOID LEADS 250
PRESTRIPPED, PRETINNED 4 MM
Description
Push Only
Push-Push
Push-Pull
Push-Pull
Push-Pull
Push-Pull
PUSHMATIC 5V
PUSHMATIC 12V
PUSHMATIC 24V
PUSHMATIC 5V
PUSHMATIC 12V
PUSHMATIC 24V
PUSHMATIC 5V
PUSHMATIC 12V
PUSHMATIC 24V
PUSHMATIC* 5V
PUSHMATIC* 12V
PUSHMATIC* 24V
PUSHMATIC** 5V
PUSHMATIC** 12V
PUSHMATIC** 24V
62
C5
C6
C7
C8
S
C4
C3
C2
C1
S
62,3
AFNOR
4,4
ISO
4,4
S
C8
C7
C6
C5
S
C1
C2
C3
C4
COUNTERSINK
5
MM LONG
COUNTERSINK
110
110
132
Fig 2
Fig 4
132
Chip
ISO
ISO
ISO Std
AFNOR
ISO+AFNOR (S)
ISO+AFNOR (P)
ISO Std
ISO Std
ISO Std
ISO+AFNOR (S)
ISO+AFNOR (S)
ISO+AFNOR (S)
ISO+AFNOR (P)
ISO+AFNOR (P)
ISO+AFNOR (P)
ISO
ISO
ISO
ISO
ISO
ISO
50
50
0,1
71,5
0,1
ACTIVE POSITION
99,2
ACTIVE POSITION
32
0,2
INACTIVE POSITION
12,5
20
INACTIVE POSITION
Diagram
Fig 1
Fig 3
Fig 2
Fig 2
Fig 2
Fig 2
Fig 4
Fig 4
Fig 4
Fig 4
Fig 4
Fig 4
Fig 4
Fig 4
Fig 4
Fig 4
Fig 4
Fig 4
Fig 4
Fig 4
Fig 4
13,3
4,5
0,4
2,8
1
1
(Typical)
(Typical)
(Typical)
(Typical)
(Typical)
(Typical)
(Typical)
(Typical)
(Typical)
(Typical)
(Typical)
(Typical)
(Typical)
(Typical)
(Typical)
J-1