Setting the Reference in Smart Remote Mode
1
2
3
4
5
6
7-14
Turn on the tester and remote and let them warm up
for 5 minutes.
On the main tester: set the following on Loss/Length
tab in Setup:
For an OptiFiber smart remote: set the following on
Loss/Length tab in Setup:
Clean the tester's and source's OUTPUT connectors and
the reference test cord connectors.
On the main tester: press
Length Reference.
Make the connections shown on the SET REFERENCE
screen and in Figure 7-6; then press
Set REMOTE END SETUP to Smart Remote.
Set THIS UNIT to Main.
Set REMOTE END SETUP to Smart Remote.
Set THIS UNIT to Remote.
F
; then select Set Loss/
t
.
7
8
See “About Setting the Reference” on page 7-10 for more
information about referencing.
Optional: From the TEST SETUP screen, you can enter
reference test cord lengths to meet TSB-140 reporting
requirements:
Use
press
done.
Press
Do not disconnect the reference test cords from
the tester's or remote's outputs after setting the
reference. If you do, you must set the reference
again to ensure valid measurements.
L
C
t
to highlight a reference test cord number,
; then enter a length. Press
OK to leave the TEST SETUP screen.
W
Caution
N
when you are