PHOTOSWITCH, POL REFLEX

E3G-MR19G

Manufacturer Part Number
E3G-MR19G
Description
PHOTOSWITCH, POL REFLEX
Manufacturer
Omron
Datasheet

Specifications of E3G-MR19G

Svhc
No SVHC (15-Dec-2010)
Sensing Range Max
10m
Sensor Input
Optical
Supply Voltage Ac Max
240VAC
Supply Voltage Dc Max
24VDC
Contact Voltage Ac Max
250VAC
Contact Voltage Dc Max
30VDC
Dielectric
RoHS Compliant
Output Type
Relay
Response Time
30ms
Rohs Compliant
Yes
Dielectric Strength Vdc
2000VAC
External Depth
68mm
External Length / Height
84.95mm
External Width
29mm
Rating/Performance
* Values in parentheses indicate the minimum required distance between the sensor and reflector.
A-122
Item
Sensing distance 10 m (500 mm) * (When using the E39-R2)
Setting distance
Standard sensing
object
Hysteresis
(typical)
Directional angle
Reflectivity
characteristics
(black/white
error)
Light source
(wave length)
Spot size
Power supply
voltage
Current/Power
consumption
Control output
Life ex-
pectan-
cy (relay
output)
Protective circuits
Response time
Sensitivity
adjustment
Timer function
Ambient
illuminance
Ambient
temperature
Ambient humidity Operating: 35% to 85%RH, Storage: 35% to 95%RH (with no condensation)
Insulation
resistance
Dielectric
strength
Vibration
resistance
Sensor type
Me-
chani-
cal
Electri-
cal
Model E3G-R13-G
Opaque: 80 dia. min.
Sensor: 1° to 5°
Red LED (700 nm)
10 to 30 VDC
[Ripple (p-p) 10% included]
50 mA max.
Load supply voltage 30
VDC max., load current 100
mA max. (residual
voltage NPN output: 1.2 V
max., PNP output: 2 V
max.) Open collector output
type (NPN/PNP output
switch selectable) L-ON/
D-ON switch selectable
Reverse polarity protection,
output short-circuit pro-
tection, mutual interference
prevention
Operation/reset: 1 ms each
One-turn adjuster
Incandescent lamp: 3,000 lux max. Sunlight 10,000 lux max.
Operating: -25°C to 55°C, Storage: -30°C to 70°C (with no icing or condensation)
20 M
1,000 VAC at 50/60 Hz for
1 minute
Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
min. at 500 VDC
Retroreflective Models (M.S.R. function)
---
---
E3G-R17-G E3G-MR19-G E3G-MR19T-G
---
---
---
---
---
12 to 240 VDC ±10% ripple
(p-p) : 10% max. 24 to 240
VAC ±10% 50/60 Hz
2 W max.
Relay output: Switch-over
contact 250 VAC 3A
(cos =1) max. 30 VDC 3A
max. L-ON/D-ON switch
selectable
50,000,000 operations min.
(switching frequency:
18,000 operations/h)
100,000 operations min.
(switching frequency: 1,800
operations/h)
Mutual interference preven-
tion function
Operation/reset: 30 ms
each
2,000 VAC at 50/60 Hz for
1 minute
ON delay/
OFF delay
0 to 5 s
(Adjuster
variable
system)
0.2 to 2 m (White paper 300 x 300 mm)
0.5 to 1.2 m (White paper 300 x 300 mm)
10% of setting distance
±10% max. (At detection distance of 1m)
Infrared LED (860 nm)
70 mm dia. max. (At detection distance of 1m)
10 to 30 VDC
(Ripple (p-p) 10% included)
60 mA max.
Load supply voltage 30
VDC max., load current 100
mA max. (residual
voltage NPN output: 1.2 V
max., PNP output: 2 V
max.) Open collector output
type (NPN/PNP output
switch selectable) L-ON/
D-ON switch selectable
Reverse polarity protection,
output short-circuit pro-
tection, mutual interference
prevention
Operation/reset: 5 ms each
Teaching method (NORMAL mode/ZONE mode)
1,000 VAC at 50/60 Hz for
1 minute
E3G-L73
---
---
Standard Photoelectric Sensors
E3G-L77
---
Distance-setting
---
---
E3G-ML79-G E3G-ML79T-G
12 to 240 VDC ±10% ripple
(p-p) : 10% max. 24 to 240
VAC ±10% 50/60 Hz
2 W max.
Relay output: Switch-over
contact 250 VAC 3A
(cos =1) max. 30 VDC 3A
max. L-ON/D-ON switch
selectable
50,000,000 operations min.
(switching frequency:
18,000 operations/h)
100,000 operations min.
(switching frequency:
1,800 operations/h)
Mutual interference preven-
tion function
Operation/reset: 30 ms
each
2,000 VAC at 50/60 Hz for
1 minute
ON delay/
OFF delay
0 to 5 s
(Adjuster
variable
system)