H3YN21DC24 Omron, H3YN21DC24 Datasheet

no-image

H3YN21DC24

Manufacturer Part Number
H3YN21DC24
Description
TIMER MINI-MULTI TIMER
Manufacturer
Omron
Datasheets

Specifications of H3YN21DC24

Rohs Compliant
YES
Lead Free Status / RoHS Status
Compliant
Miniature Timer with Multiple Time Ranges
and Multiple Operating Modes
• Minimizes stock.
• Pin configuration compatible with MY Power Relay.
• Standard multiple operating modes and multiple time ranges.
• Conforms to EN61812-1 and IEC60664-1 for Low Voltage, and
Model Number Structure
■ Model Number Legend
1. Output
2. Time Range
Ordering Information
■ List of Models
Note: 1. Sockets and Hold-down Clips are not included with the H3YN. They must be ordered separately.
■ Accessories (Order Separately)
Connecting Socket
H3YN-@@-@
Note: Specify both the model number and supply voltage when ordering.
24, 100 to 120, 200 to 230 VAC;
12, 24, 48, 100 to 110, 125 VDC
24 VDC
H3YN-2/-21
H3YN-4/-41
H3YN-4-Z/-41-Z
EMC Directives.
Solid-state Timer
H3YN
2: DPDT
4: 4PDT
None: Short-time range (0.1 s to 10 min)
1:
2. Only models with 24-VDC power supply are available.
3. Use the H3YN-4 or H3YN-41 Series when switching micro loads, and use the H3YN-4-Z or H3YN-41-Z Series when switching even
smaller loads.
Long-time range (0.1 min to 10 hrs)
Supply voltage
Example: H3YN-2 24 VAC
1 2
Timer
3
PYF08A, PYF08A-N,
PYF08A-E
PYF14A, PYF14A-N,
PYF14A-E
Track-mounting/Front-
connecting Socket
DPDT
4PDT
4PDT (Twin contacts)
Supply voltage
Time-limit contact
PY08
PY14
Solder terminal
H3YN-2
H3YN-4
H3YN-4-Z
3. Contact Type
Short-time range model
None: Single contact
Z:
(0.1 s to 10 min)
Twin contacts
PY08QN(2)
PY14QN(2)
Back-connecting Socket
Wire-wrap terminal
H3YN-21
H3YN-41
H3YN-41-Z
Long-time range model
PY08-02
PY14-02
(0.1 min to 10 h)
CSM_H3YN_DS_E_2_1
PC terminal
1

Related parts for H3YN21DC24

H3YN21DC24 Summary of contents

Page 1

Solid-state Timer H3YN Miniature Timer with Multiple Time Ranges and Multiple Operating Modes • Minimizes stock. • Pin configuration compatible with MY Power Relay. • Standard multiple operating modes and multiple time ranges. • Conforms to EN61812-1 and IEC60664-1 for ...

Page 2

Hold-down Clips Model Applicable Socket Y92H-3 PYF08A, PYF08A-N, PYF08A-E PYF14A, PYF14A-N, PYF14A-E Y92H-4 PY08, PY08QN(2), PY08-02 PY14, PY14QN(2), PY14-02 Specifications ■ Ratings Item Time ranges 0 min ( min min max. ...

Page 3

Characteristics Item ±1% FS max range: ±1%±10 ms max.) Accuracy of operating time ±10%± max. Setting error Reset time Min. power-opening time: 0.1 s max. (including halfway reset) ±2% FS max. Influence of voltage ±2% ...

Page 4

Life-test Curve (Reference Value) H3YN-2/-21 5,000 250 VAC, cosφ VDC, cosφ 1,000 500 200 Load current (A) Reference: A maximum current of 0.6 A can be switched at 125 VDC (cosφ = 1). Maximum ...

Page 5

Connections ■ Connection H3YN-2/-21 DIN Indication Timer circuit UP PW Pulse Operation A pulse output for a certain period can be obtained with a random external input signal. Use the H3YN in interval mode as shown in the following timing ...

Page 6

Operation ■ Timing Chart Operating mode ON-delay Power (13-14) Power Time limit contact NC (9-1, 12-4) Output Time limit contact NO (9-5, 12-8) Run/Power indicator (PW) Output indicator Interval Power (13-14) Power Time limit contact NC (9-1, 12-4) Output Time ...

Page 7

DIP Switch Settings The 1-s range and ON-delay mode for H3YN-2/-4/-4-Z, the 1-min range and ON-delay mode for H3YN-21/-41/-41-Z are factory-set before shipping. Time Ranges Model Time range Time setting range H3YN- 0 H3YN-4 ...

Page 8

Dimensions Note: All units are in millimeters unless otherwise indicated. ■ Timers H3YN-2/-21 Front Mounting H3YN-4/-41 Front Mounting H3YN-4-Z/-41-Z Mounting Height PY08 (PY14 (see note)) PYF08A/PYF08A-N/PYF08A-E (PYF14A/PYF14A-N/PYF14A-E (see note)) H3YN Series PYF08A (PYF14A) Note: Models in parentheses are Connecting Sockets ...

Page 9

Accessories (Order Separately) Connecting Sockets Use the PYF@A, PY@, PY@-02, or PY@QN(2) to mount the H3YN. When ordering any one of these Sockets, replace “@” with “08” or “14.” Track Mounting/Front Connecting Sockets PYF08A Two, 4.2 × 5 3.4 ...

Page 10

PYF08A-E Two, 4.2 × 5 Eight, M3 × mounting holes 8 sems 72 max. 23 max. 31 max. PYF14A-E Two, 4.2 × 5 mounting holes Fourteen, M3 × 8 sems 72 max. 29.5 max. 31 max. Back Connecting Sockets PY08, ...

Page 11

Flush Mounting Adapter Y92F-78 27.1 Socket Mounting Plates The PYP Socket Mounting Plate for a single Socket and the PYP- Socket Mounting Plate for 18 Sockets. The PYP-18 can be cut appropriately according to the number ...

Page 12

Safety Precautions Refer to Safety Precautions for All Timers. ■ Correct Use The operating voltage will increase when using the H3YN continu- ously in any place where the ambient temperature range of 45°C to 50°C. Supply 90% ...

Page 13

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...